ECB07/08/2026Failure to maintain building facade wall"s" and appurtenances. Note: at the time of inspection, i observed at ex #4, north elevation, step cracked bricks near parapet level/roof. Spalling mortar joints near roo$2K due
ECB04/20/2026Failure to file acceptable amended cycle 9C report indicating correction of unsafe conditions described in initial facades report required by 28-302.5 for control #910486. Remedy: file acceptable report.$1K due
ECB03/16/2025Observed active facade operations using suspended scaffold, upon review the department records observed general contractor license# 618608 for facade operation non-registered and has tracking number only. Also$5K due
DOB06/05/2024Partial vacate order due to unsafe notification filed for 60 west end ave as observed of cracked and displaced bricks at courtyard west elev ation and deteriorated bricks as well as unsecured hazard materials at playground at north elev.these conditions have therefore made the enti re courtyard and playground unable to be occupied.remedy:vacate
DOB06/02/2024Cycle 9C unsafe report filed
DOB05/29/2024Emergency work order due to cracked,spalling and deteriorated brick fa ce and stone as deteriorated mortar joints at multiple locations at ex P1 east elev and EXP2 south elev and EXP3 west elev.remedy:provide ade quate safety measures.repair unsafe facade as per 1RCNY 103.04.file as unsafe report
DOB02/22/2024Failed to file FISP cycle 9C technical report by 2/21/2024
ECB05/21/2026Failure to maintain exterior building facade and appurtenances. Notes at the time of inspection observed at exposure 2 south elevation cracked brick with open mortar joints. At exposure 3 west cracked brick witHearing held — result not yet published$2K proposed
ECB08/01/2024Failure to maintain building facade and appurtenances. Observed damaged mortar joints in multiple locations on exposure 1. Also observed cracked stone work on exposure 2. Remedy: maintain building facade. TakeNothing owed — awaiting certificate of correction
ECB09/12/2022Out of service. Upon inspection, the device is found to be out-of-service remedy: restore to service immediately and, notify nycdob the device has been returned to service. E-mail eir@buildings.NYC.gov so an inNothing owed — awaiting certificate of correction
ECB08/15/2017Salnt fin boiler model #GG300E is not registerd.rem:register boiler & submit a cert of correction.Nothing owed — awaiting certificate of correction
ECB10/05/2016Failure to maintain bldg in code compliant manner.noted:@time of inspection observed exit door @stairwell north is 32" door.code requires a minimum of 36" door for proper egress out of bldg.fire doors are missiNothing owed — awaiting certificate of correction
ECB07/29/2016Failure to provide approved plans at job site at time of inspection. Noted: at time of inspection,active work site w/approx 6-8 workers. No approved plans on site to show removal of staircase & removal or windoNothing owed — awaiting certificate of correction
ECB04/16/2015Failure to file an acceptable cycle 7 technical report in compliance with code provisions: periodic inspection of exterior walls & appurtenances as required by article 28-302 & the dept of bldgs rules & regulatNothing owed — awaiting certificate of correction
ECB02/11/2009Occupancy contrary to that allowed by the certificate of occupancy. Note: co of o number 178655 date 19 feb 1962 indicates the occupancy of the 6TH as a locker room, steam room etc. The locker room was convertNothing owed — awaiting certificate of correction