← Back
Elevator apt, semi-fireproof with stores
2881 BROADWAY
MANHATTAN · Morningside Heights · BIN 1057336
💬 Discuss this project
1902Year Built
7Stories
D7Building Class
R8Zoning
59,131 sfGross Floor Area
43Units
LL97 CoveredRent Stabilized96 Open Violations 87 unresolved · 9 paperwork only ▸FISP: SAFE
Elevator apt, semi-fireproof with stores · Owner of record: TRUSTEES OF COLUMBIA UNIVERSITY · 10,092 sf lot · 5.86 FAR built · Flood zone X
Locations of Work
ArchitectureStructuralMechanicalPlumbingEquipmentGeneral
Roof1p · 1 filing · 6 docs
Floor 751p · 5 filings · 20 docs
Floor 61p · 1 filing · 6 docs
Floor 536p · 4 filings · 20 docs
Floor 436p · 4 filings · 20 docs
Floor 353p · 5 filings · 20 docs
Floor 21p · 1 filing · 6 docs
Floor 15p · 2 filings · 20 docs
Cellar1p · 1 filing · 14 docs
Site & exterior14p · 3 filings · 14 docs
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
COLUMBIA RESIDENTIAL4007/08/2026
COLUMBIA UNIVERSITY2107/08/2026
NEW ROC CONTRACTING1007/08/2026
CAPTIAL MANAGEMENT203/21/2026
COLUMBIA UNIVERSITY FACILITIES103/21/2026
▾Design Consultants (Architect / Engineer of Record)
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
M HASHAS1203/21/2026
NYCCODE2003/21/2026
NEW YORK ENGINEERING ASSOCIATES P603/21/2026
SBLM403/21/2026
HOFFMANN ARCHITECTS203/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
E.J. YORK INCGeneral Contractor1007/08/2026
COSMOPOLITAN CONSTRUCTIO*General Contractor807/08/2026
ANDREW LIVADITISElectrical403/21/2026
ANDAMIO SCAFFOLDING LLCGeneral Contractor407/08/2026
NEW ROC CONTRACTING CORPGeneral Contractor307/08/2026
ALAFOGIANNIS PLBG & HTGPlumbing307/08/2026
DUNN, JEREMYElectrical203/21/2026
DIFUSCO, ALFONSOElectrical203/21/2026
CRUGNALE, MICHAELElectrical203/21/2026
TESTERMAN PLBG & HTG INCPlumbing107/08/2026
BOROWIDE ELECT'L CONTR'SElectrical103/22/2026
COBRA ELECTRIC CORP.Electrical103/22/2026
CHAMPION MECHANICAL INCGeneral Contractor107/08/2026
IDEAL ROOFING & SHEET MEGeneral Contractor107/08/2026
PACE PLUMBING CORPPlumbing107/08/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
CES ENGINEERING LLC12771012/18/2023
COLE TECHNOLOGIES/CONTROL1290406/06/2023
SBLM ARCHITECTS, PC3678309/27/2022
BLUE SKY DESIGN, INC.1908104/04/2022
INTEGRITY CONSULTING SERV666103/16/2022
Building Lifecycle
All (175)Filed (28)Permit Issued (20)Signed Off (13)Facade (FISP) (12)Violation (60)Inspection (10)Objection (2)Special Inspection (30)
12/16/2025
Signed off — Alteration
REPLACEMENT OF HANDRAILS AT FRONT PORCH
M01298645-I1
11/10/2025
Permit issued — General Construction
M01298645-I1-GC
10/28/2025
Filed — Alteration
REPLACEMENT OF HANDRAILS AT FRONT PORCH
M01298645-I1
10/06/2025
Special inspection requirement — Final
ASDRUBAL FRANCO
07/01/2024
Signed off — Alteration
plumbing work associated with interior RENOVATION OF A RESIDENTIAL APARTMENT. no change to use, egress, or occupancy
M00764661-S2
06/28/2024
Signed off — Alteration
plumbing work associated with interior RENOVATION OF A RESIDENTIAL APARTMENT. no change to use, egress, or occupancy
M00764661-I1
06/27/2024
Signed off — Alteration
plumbing work associated with interior RENOVATION OF A RESIDENTIAL APARTMENT. no change to use, egress, or occupancy
M00764661-S1
06/27/2024
Inspection — Certified Water and Sanitary-WS-Fixtures-Finish
Certified
View inspection ↗
04/26/2024
Violation issued (HPD, closed)
B
04/01/2024
Violation issued (HPD, closed)
A
03/06/2024
Violation issued (ECB, closed)
Construction
02/08/2024
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Roughing
Certified
View inspection ↗
02/02/2024
Signed off — Alteration
mechanical work associated with apartments renovation as shown on plans filed herewith. no change to use, egress, or occupancy.
M00765930-I1
02/01/2024
Signed off — Alteration
mechanical work associated with apartments renovation as shown on plans filed herewith. no change to use, egress, or occupancy.
M00765930-S2
02/01/2024
Signed off — Alteration
mechanical work associated with apartments renovation as shown on plans filed herewith. no change to use, egress, or occupancy.
M00765930-S1
12/20/2023
Violation issued (ECB, closed)
Construction
12/18/2023
Filed — Alteration
plumbing work associated with interior RENOVATION OF A RESIDENTIAL APARTMENT. no change to use, egress, or occupancy
M00764661-P1
12/14/2023
Special inspection requirement — Fire-Resistant Penetrations and Joints
Delbert Smith
11/09/2023
Filed — Alteration
mechanical work associated with apartments renovation as shown on plans filed herewith. no change to use, egress, or occupancy.
M00765930-P3
11/09/2023
Special inspection requirement — Fire-Resistant Penetrations and Joints
Delbert Smith
11/08/2023
Special inspection requirement — Fire-Resistant Penetrations and Joints
Delbert Smith
10/17/2023
Inspection — Certified Water and Sanitary-WS-Fixtures-Finish
Certified
View inspection ↗
10/10/2023
Permit issued — Plumbing
M00764661-S2-PL
10/06/2023
Permit issued — General Construction
M00764661-I1-GC
10/03/2023
Permit issued — Mechanical Systems
M00764661-S1-MS
08/23/2023
Cycle 9 facade report submitted
08/22/2023
Cycle 9 facade report signed — SAFE
08/21/2023
Signed off — Alteration
Filing for the structural work in conjunction with the renovation of the apartments.
M00667300-I1
08/17/2023
Filed — Alteration
mechanical work associated with apartments renovation as shown on plans filed herewith. no change to use, egress, or occupancy.
M00765930-P1
08/17/2023
Filed — Alteration
mechanical work associated with apartments renovation as shown on plans filed herewith. no change to use, egress, or occupancy.
M00765930-P2
08/17/2023
Signed off — Alteration
Filing to renovate apartments 3D, 4D, 5D and 7D. Remove and install interior partitions and finishes. No change in use, egress or occupancy.
M00657917-I1
08/16/2023
Signed off — Alteration
Repairs of facade as shown on drawings filed herewith.
M00708743-I1
08/16/2023
Cycle 9 facade inspection completed
08/14/2023
Special inspection requirement — Fire-Resistant Penetrations and Joints
Delbert Smith
08/14/2023
Special inspection requirement — Final
Peter Votto
08/14/2023
Special inspection requirement — Mechanical Systems
Delbert Smith
07/24/2023
Signed off — Alteration
INSTALLATION OF TEMPORARY HEAVY DUTY SIDEWALK SHED AS PER PLANS. NO CHANGE IN USE, EGRESS OR OCCUPANCY. SIDEWALK SHED SHALL COMPLY WITH CHAPTER #33 OF THE NYC BUILDING CODE. LIVE LOAD 300PSF.
M00770491-I1
06/26/2023
Permit issued — Sidewalk Shed
M00770491-I1-SH
06/22/2023
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Roughing
Certified
View inspection ↗
06/12/2023
Special inspection requirement — Structural Stability – Alterations of existing buildings
GEORGE ANDERSEN
06/12/2023
Special inspection requirement — Structural Steel - Details
GEORGE ANDERSEN
06/12/2023
Special inspection requirement — Structural Cold-Formed Steel
GEORGE ANDERSEN
06/12/2023
Special inspection requirement — Structural Wood Frame
GEORGE ANDERSEN
06/12/2023
Special inspection requirement — Final
GEORGE ANDERSEN
06/06/2023
Filed — Alteration
Filing for the structural work in conjunction with the renovation of the apartments.
M00667300-P1
04/20/2023
Permit issued — Mechanical Systems
M00765930-S2-MS
04/11/2023
Permit issued — Plumbing
M00765930-S1-PL
03/30/2023
Objection raised — Admin
03/30/2023
Objection resolved — Addressed
03/24/2023
Signed off — Alteration
Filing for the structural work in conjunction with the renovation of the apartments.
M00667300-S1
03/23/2023
Permit issued — General Construction
M00765930-I1-GC
03/22/2023
Filed — Alteration
mechanical work associated with apartments renovation as shown on plans filed herewith. no change to use, egress, or occupancy.
M00765930-S2
03/22/2023
Filed — Alteration
mechanical work associated with apartments renovation as shown on plans filed herewith. no change to use, egress, or occupancy.
M00765930-S1
03/16/2023
Signed off — Alteration
Filing for the plumbing work in conjunction with the renovation of the apartments 3D, 4D, 5D and 7D.
M00667296-I1
03/10/2023
Filed — Alteration
mechanical work associated with apartments renovation as shown on plans filed herewith. no change to use, egress, or occupancy.
M00765930-I1
01/31/2023
Permit issued — General Construction
M00708743-I1-GC
01/26/2023
Filed — Alteration
Filing for the plumbing work in conjunction with the renovation of the apartments 3D, 4D, 5D and 7D.
M00667296-P1
12/23/2022
Filed — Alteration
INSTALLATION OF TEMPORARY HEAVY DUTY SIDEWALK SHED AS PER PLANS. NO CHANGE IN USE, EGRESS OR OCCUPANCY. SIDEWALK SHED SHALL COMPLY WITH CHAPTER #33 OF THE NYC BUILDING CODE. LIVE LOAD 300PSF.
M00770491-P2
12/20/2022
Violation issued (ECB, closed)
Local Law
12/02/2022
Filed — Alteration
INSTALLATION OF TEMPORARY HEAVY DUTY SIDEWALK SHED AS PER PLANS. NO CHANGE IN USE, EGRESS OR OCCUPANCY. SIDEWALK SHED SHALL COMPLY WITH CHAPTER #33 OF THE NYC BUILDING CODE. LIVE LOAD 300PSF.
M00770491-P1
Latest 60 of 175 events.
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWGeneral ConstructionSigned-offIDEAL ROOFING SHEET ME11/10/2025
DOB NOWPlumbingSigned-offALAFOGIANNIS PLBG & HTG10/10/2023
DOB NOWGeneral ConstructionSigned-offCOSMOPOLITAN CONSTRUCTIO*10/06/2023
DOB NOWMechanical SystemsSigned-offCOSMOPOLITAN CONSTRUCTIO*10/03/2023
DOB NOWSidewalk ShedSigned-offANDAMIO SCAFFOLDING LLC06/26/2023
DOB NOWMechanical SystemsSigned-offCOSMOPOLITAN CONSTRUCTIO*04/20/2023
DOB NOWPlumbingSigned-offALAFOGIANNIS PLBG & HTG04/11/2023
DOB NOWGeneral ConstructionSigned-offCOSMOPOLITAN CONSTRUCTIO*03/23/2023
DOB NOWGeneral ConstructionSigned-offNEW ROC CONTRACTING CORP01/31/2023
DOB NOWGeneral ConstructionSigned-offNEW ROC CONTRACTING CORP08/01/2022
DOB NOWStructuralSigned-offEJ YORK INC07/19/2022
DOB NOWStructuralSigned-offEJ YORK INC07/19/2022
DOB NOWGeneral ConstructionSigned-offEJ YORK INC07/19/2022
DOB NOWSidewalk ShedSigned-offANDAMIO SCAFFOLDING LLC07/07/2022
DOB NOWPlumbingSigned-offPACE PLUMBING CORP05/25/2022
DOB NOWMechanical SystemsPermit IssuedCHAMPION MECHANICAL05/24/2022
DOB NOWPlumbingSigned-offTESTERMAN PLBG & HTG INC04/27/2022
DOB NOWStructuralSigned-offEJ YORK INC04/21/2022
DOB NOWGeneral ConstructionSigned-offEJ YORK INC04/21/2022
DOB NOWPlumbingPermit IssuedALAFOGIANNIS PLBG & HTG06/11/2020
BISOTISSUEDBILTMORE GENERAL CONTRACTORS09/05/2019
BISPLISSUEDEH PLUMBING & HEATING COR04/03/2019
BISOTISSUEDBILTMORE GENERAL CONTRACTORS03/21/2019
BISOTISSUEDTHE TRUSTEES OF COLUMBIA12/12/2017
BISFPISSUEDMASTER FIRE SYSTEMS, INC12/24/2015
BISPLISSUEDABSOLUTE PLBG & HTG CORP02/04/2014
BISOTISSUEDHENRY RESTORATION LTD12/02/2013
BISEQISSUEDEVEREST SCAFFOLDING INC10/29/2013
BISOTISSUEDHENRY RESTORATION LTD03/29/2013
BISPLISSUEDABSOLUTE PLBG & HTG CORP01/02/2013
BISOTISSUEDCOLUMBIA UNIVERSITY12/06/2012
BISEQISSUEDEVEREST SCAFFOLDING INC11/14/2012
BISPLISSUEDABSOLUTE PLBG & HTG CORP08/06/2010
BISOTISSUEDCOLUMBIA UNIVERSITY07/14/2010
BISPLISSUEDABSOLUTE PLBG & HTG CORP02/23/2009
BISOTISSUEDCOLUMBIA UNIVERSITY02/09/2009
BISEQISSUEDWEST NEW YORK RESTORATION OF CT01/09/2009
BISOTISSUEDHENRY RESTORATION LTD07/11/2008
BISFSISSUEDC C CONTROLLED COMBUSTION04/11/2008
BISOTISSUEDCOLUMBIA UNIVERSITY04/08/2008
+ 16 more permits on file
2 projects · most recent 09/27/2022
Gas Plumbing-Sprinkler Water/Sanitary
FiledStatusContractorScope
09/27/2022Signed-offPACE PLUMBING CORPGas
11/03/2020Permit IssuedALAFOGIANNIS PLBG & HTGGas, Plumbing-Sprinkler, Water/Sanitary
9 projects · most recent 10/09/2023
General Wiring
FiledStatusContractorScope
10/09/2023CompleteDOUMAS ELECTRIC INC.General Wiring
10/09/2023CompleteDOUMAS ELECTRIC INC.—
03/27/2023Permit IssuedDOUMAS ELECTRIC INC.General Wiring
03/27/2023CompleteDOUMAS ELECTRIC INC.—
07/15/2022CompleteBOROWIDE ELECT'L CONTR'S—
05/20/2022CompleteCOBRA ELECTRIC CORP.—
04/27/2022CompleteCOBRA ELECTRIC CORP.General Wiring
11/18/2020Permit IssuedA ELECTRICAL MAIN SVC INCGeneral Wiring
04/25/2019Permit IssuedJOSEPH WEINSTEIN ELECTRICGeneral Wiring
▾Field Inspections (DOB CAP) — 10
DateTypeResultReport
06/27/2024Certified Water and Sanitary-WS-Fixtures-FinishCertifiedView ↗
02/08/2024Certified Water and Sanitary-WS-Sanitary Piping-RoughingCertifiedView ↗
10/17/2023Certified Water and Sanitary-WS-Fixtures-FinishCertifiedView ↗
06/22/2023Certified Water and Sanitary-WS-Sanitary Piping-RoughingCertifiedView ↗
09/09/2022Pass-Final PL - Up to 3 Requested FloorsPassView ↗
09/06/2022Certified Gas-Gas-Piping-RoughingCertifiedView ↗
08/31/2022Certified Water and Sanitary-WS-Sanitary Piping-RoughingCertifiedView ↗
08/26/2022Fail-Final PL - Up to 3 Requested FloorsFailView ↗
08/12/2022Pass-Final PL - Up to 3 Requested FloorsPassView ↗
06/24/2022Fail-Final PL - Up to 3 Requested FloorsFailView ↗
▾Special Inspection Requirements (DOB NOW) — 31
DateRequirementInspectorRole
10/06/2025FinalASDRUBAL FRANCOprogress
12/14/2023Fire-Resistant Penetrations and JointsDelbert Smithspecial
11/09/2023Fire-Resistant Penetrations and JointsDelbert Smithspecial
11/08/2023Fire-Resistant Penetrations and JointsDelbert Smithspecial
08/14/2023Fire-Resistant Penetrations and JointsDelbert Smithspecial
08/14/2023FinalPeter Vottoprogress
08/14/2023Mechanical SystemsDelbert Smithspecial
06/12/2023Structural Stability – Alterations of existing buildingsGEORGE ANDERSENspecial
06/12/2023Structural Steel - DetailsGEORGE ANDERSENspecial
06/12/2023Structural Cold-Formed SteelGEORGE ANDERSENspecial
06/12/2023Structural Wood FrameGEORGE ANDERSENprogress
06/12/2023FinalGEORGE ANDERSENprogress
09/27/2022Fire-Resistant Penetrations and JointsDavid Nicholsonspecial
09/27/2022Energy Code Compliance InspectionsDavid Nicholsonprogress
08/09/2022Fire-Resistant Penetrations and JointsDelbert Smithspecial
08/02/2022FinalPeter Vottoprogress
08/02/2022Mechanical SystemsDelbert Smithspecial
06/29/2022Fire-Resistant Penetrations and JointsDelbert Smithspecial
06/28/2022Finalkaren fromeprogress
06/28/2022Fire-Resistant Penetrations and JointsDelbert Smithspecial
06/28/2022Finalkaren fromeprogress
03/15/2022Fire-Resistant Penetrations and JointsALEKSANDR LEVINspecial
02/04/2022Lighting in dwelling unitsGEORGE ANDERSENenergy_progress
02/04/2022Fire-Resistant Penetrations and JointsGEORGE ANDERSENspecial
02/04/2022Structural Stability – Alterations of existing buildingsGEORGE ANDERSENspecial
Latest 25 of 31.
▾Documents — 343 on file (BIS + DOB NOW)
▸Plans & Drawings29
▸DOB NOWPlans/Sketch26
09/02/2026M00657917-I1Request digital key ↗
09/02/2026M00667300-P1Request digital key ↗
09/02/2026M00667300-S1Request digital key ↗
Showing 3 of 26 on file for this type
▸DOB NOWPlans/Sketch - Plumbing3
09/04/2026M00352464-I1Request digital key ↗
08/15/2026M00352464-P1Request digital key ↗
08/15/2026M00352464-P2Request digital key ↗
▸Applications & Permits69
▸DOB NOWLPC Approval/Permit26
09/02/2026M00657917-I1Open ↗
09/02/2026M00667300-I1Open ↗
08/13/2026M00667300-P1Open ↗
Showing 3 of 26 on file for this type
▸BISWORK PERMIT APPLICATION24
09/06/2019140832981Open ↗
04/04/2019140832981Open ↗
03/21/2019140832981Open ↗
Showing 3 of 24 on file for this type
▸BISPLAN / WORK APPROVAL APPLICATION19
03/26/2019140774589Open ↗
03/06/2019140832981Open ↗
07/03/2018140774589Open ↗
Showing 3 of 19 on file for this type
▸Seals & Professional Certifications103
▸DOB NOWDPL-1: Design Professional Seal & Signature29
09/02/2026M00657917-I1Open ↗
09/02/2026M00667300-I1Open ↗
09/02/2026M00770491-P2Open ↗
Showing 3 of 29 on file for this type
▸BISTECHNICAL REPORT: RESPONSIBILITY/CERTIFICATION27
10/29/2018140774589Open ↗
08/09/2017123330582Open ↗
04/13/2016122469462Open ↗
Showing 3 of 27 on file for this type
▸DOB NOWSpecial Inspector Seal & Signature16
09/01/2026M00765930-S1Open ↗
09/01/2026M00764661-P1Open ↗
09/01/2026M00667300-I1Open ↗
Showing 3 of 16 on file for this type
▸DOB NOWProgress Inspector Seal & Signature14
09/01/2026M00352464-P2Open ↗
09/01/2026M00667300-I1Open ↗
09/01/2026M00667300-I1Open ↗
Showing 3 of 14 on file for this type
▸BISPROFESSIONAL CERTIFIED CHECKLIST4
01/05/2016122606750Open ↗
11/19/2012121435410Open ↗
05/01/2008110156679Open ↗
Showing 3 of 4 on file for this type
▸BISPROFESSIONAL CERTIFICATION STATEMENT4
03/06/2019140832981Open ↗
07/03/2018140774589Open ↗
01/05/2016122606750Open ↗
Showing 3 of 4 on file for this type
▸BISPROFESSIONAL CERTIFICATION STATEMENT FORM3
11/19/2012121435410Open ↗
05/01/2008110156679Open ↗
02/06/2008110069309Open ↗
▸BISREQUIRED ITEMS CHECKLIST FOR PROFESSIONAL CERTIFICATION3
03/06/2019140832981Open ↗
07/03/2018140774589Open ↗
11/14/2012140038224Open ↗
▸BISTECHNICAL REPORT STATEMENT OF RESPONSIBILITY3
03/06/2019140832981Open ↗
07/03/2018140774589Open ↗
11/14/2012140038224Open ↗
▸Trade Schedules & Equipment16
▸BISSCHEDULE B - PLUMBING8
03/06/2019140832981Open ↗
07/03/2018140774589Open ↗
11/13/2012121422095Open ↗
Showing 3 of 8 on file for this type
▸BISSELF-CERT PLUMBING NOTICE4
02/20/2014121422095Open ↗
02/06/2013121422095Open ↗
08/26/2011120359931Open ↗
Showing 3 of 4 on file for this type
▸BISSCHEDULE B - PLUMBING/SPRINKLER/STANDPIPE2
08/09/2017123330582Open ↗
04/13/2016122469462Open ↗
▸BISSCHEDULE C - HEATING & COMBUSTION EQUIPMENT1
04/01/2008110121760Open ↗
▸BISDETECTOR:SMOKE-CERT. OF INSTALLATION1
10/29/2018140774589Open ↗
▸Safety & Tenant Protection7
▸BISTENANT PROTECTION PLAN AND NOTES4
03/06/2019140832981Open ↗
07/03/2018140774589Open ↗
08/09/2017123330582Open ↗
Showing 3 of 4 on file for this type
▸DOB NOWTenant Protection Plan3
08/13/2026M00352464-P2Open ↗
08/13/2026M00352464-I1Open ↗
08/13/2026M00352464-P1Open ↗
▸Environmental & Asbestos36
▸DOB NOWDEP ACP-5: Asbestos Assessment Report16
09/02/2026M00764661-I1Open ↗
09/02/2026M00764661-S1Open ↗
09/02/2026M00764661-S2Open ↗
Showing 3 of 16 on file for this type
▸BISTHIS IS 'NOT AN ASBESTOS PROJECT'8
05/24/2010120359931Open ↗
01/12/2009110430454Open ↗
05/30/2008110184087Open ↗
Showing 3 of 8 on file for this type
▸BISASBESTOS: CERTIFICATION (DEP ACP5)6
03/06/2019140832981Open ↗
07/03/2018140774589Open ↗
08/09/2017123330582Open ↗
Showing 3 of 6 on file for this type
▸DOB NOWDEP ACP-20/ACP-21: Asbestos Project Conditional Completion Form/Asbestos Project Completion Form4
09/02/2026M00657917-I1Open ↗
09/01/2026M00667296-I1Open ↗
08/13/2026M00667300-I1Open ↗
Showing 3 of 4 on file for this type
▸BISASBESTOS EXEMPTION CERTIFICATION LETTER2
05/07/2008110162458Open ↗
05/01/2008110156679Open ↗
▸Energy Compliance16
▸BISTECHNICAL REPORT: ENERGY CODE PROGRESS INSPS6
10/29/2018140774589Open ↗
08/09/2017123330582Open ↗
04/13/2016122469462Open ↗
Showing 3 of 6 on file for this type
▸BISAS-BUILT ENERGY ANALYSIS3
10/29/2018140774589Open ↗
12/24/2014121422095Open ↗
06/24/2014121435410Open ↗
▸BISTECHNICAL REPORT STATEMENT OF RESPONSIBILITY FOR ENERGY CODE PROGRESS INSPECTIONS2
03/06/2019140832981Open ↗
07/03/2018140774589Open ↗
▸BISTECHNICAL REPORT: ENERGY CODE - RESPONSIBILITY2
03/06/2019140832981Open ↗
07/03/2018140774589Open ↗
▸BISELECTRICAL APPLICATION FOR SIDEWALK SHED LIGHTING1
11/14/2012140038224Open ↗
▸BISTR8: Energy Code Progress Inspections1
06/24/2014121435410Open ↗
▸DOB NOWEN2: As Built Energy Analysis1
09/02/2026M00657917-I1Open ↗
▸Inspections & Test Reports3
▸BISTECHNICAL REPORT: RESPONSIBILITY3
03/06/2019140832981Open ↗
07/03/2018140774589Open ↗
11/14/2012140038224Open ↗
▸Approvals, Objections & Sign-offs22
▸BISADMINISTRATIVE OBJECTIONS10
11/19/2012121435410Open ↗
11/13/2012121422095Open ↗
05/24/2010120359931Open ↗
Showing 3 of 10 on file for this type
▸BISCERTIFICATE OF OCCUPANCY/LOC: REQUEST9
10/29/2018140774589Open ↗
12/24/2014110069309Open ↗
12/24/2014121422095Open ↗
Showing 3 of 9 on file for this type
▸BISLANDMARKS APPROVAL2
03/06/2019140832981Open ↗
07/03/2018140774589Open ↗
▸BISLETTERS - SUPPORTING DOCUMENTATION1
05/07/2014140038224Open ↗
▸Cost, Insurance & Ownership22
▸BISCOST AFFIDAVIT21
03/06/2019140832981Open ↗
10/29/2018140774589Open ↗
07/03/2018140774589Open ↗
Showing 3 of 21 on file for this type
▸BISHIC LICENSE OR AFFIDAVIT1
02/09/2009110430454Open ↗
▸Filing & Intake Forms15
▸BISEFILING COVER SHEET7
08/09/2017123330582Open ↗
01/05/2016122606750Open ↗
11/19/2012121435410Open ↗
Showing 3 of 7 on file for this type
▸BISBOROUGH INTAKE FORM3
03/26/2019140774589Open ↗
10/29/2018140774589Open ↗
06/29/2018122606750Open ↗
▸BISEFILING JOB APPLICATION COVER SHEET3
03/06/2019140832981Open ↗
07/03/2018140774589Open ↗
11/14/2012140038224Open ↗
▸BISADDITIONAL INFORMATION2
04/09/2014140038224Open ↗
07/20/2010120359931Open ↗
▸Other Documents5
▸BISCONSTRUCTION - SUPPORTING DOCUMENTATION2
11/14/2012140038224Open ↗
11/14/2012140038224Open ↗
▸DOB NOWProof of Historic Building2
08/13/2026M00764661-I1Open ↗
08/13/2026M00765930-I1Open ↗
▸BISEXTERNAL FORMS - SUPPORTING DOCUMENTATION1
12/13/2012110162458Open ↗