HPD06/01/2026§ 27-2026 ADM CODE REPAIR THE LEAKY AND/OR DEFECTIVE FAUCETS AT SHOWER STALL IN THE BATHROOM LOCATED AT APT 1 LOWER LEVEL, 1st STORY, 2nd APARTMENT FROM NORTH AT EAST
HPD06/01/2026§ 27-2005, 27-2007, 27-2041.1 HMC, §238, § 309; § 107 (2) ( C) MDL AND 28 RCNY §25-171: REPLACE OR REPAIR THE SELF-CLOSING DOORS THAT IS MISSING OR DEFECTIVE LATCH SET AT DOOR LEADING TO CELLAR AT PUBLIC HALL, 1st STORY
HPD06/01/2026§ 27-2021 ADM CODE PROVIDE SUFFICIENT, PROPER AND SEPARATE METAL RECEPTACLES FOR THE DEPOSIT OF GARBAGE, RUBBISH AND OTHER WASTE MATERIAL AND ARRANGE FOR COLLECTION AND DISPOSAL OF SUCH MATERIAL.
HPD06/01/2026567 (C) § 27-2017, 27-2017.1, 27-2017.4, 27-2017.5, 27-2017.8, 27-2019, 27-2021 HMC: ABATE THE NUISANCE CONSISTING OF EVIDENCE OF RATS AND ALL UNDERLYING CAUSES CREATING THE PEST INFESTATIONS, BY USING INTEGRATED PEST MANAGEMENT (IPM), ELIMINATE ALL BURROW ENTRY AND PASSAGEWAYS, PEST NESTS, HOLES, GAPS OR CRACKS IN WALLS, CEILINGS, FLOORS, FIXING LEAKS AND MANAGING GARBAGE IN PUBLIC AREAS. EVIDENCE FOUND AT ... AT CELLAR
HPD04/29/2026(A) § HMC:FILE ANNUAL BEDBUG REPORT IN ACCORDANCE WITH HPD RULE AS DESCRIBED ON THE BACK OF THIS NOTICE OF VIOLATION OR AS DESCRIBED ON HPDS WEBSITE, WWW.NYC.GOV\HPD, SEARCH BED BUGS.
HPD06/04/2025(A) § HMC:FILE ANNUAL BEDBUG REPORT IN ACCORDANCE WITH HPD RULE AS DESCRIBED ON THE BACK OF THIS NOTICE OF VIOLATION OR AS DESCRIBED ON HPDS WEBSITE, WWW.NYC.GOV\HPD, SEARCH BED BUGS.
HPD03/05/2025§ 27-2045 ADM CODE REPAIR OR REPLACE THE SMOKE DETECTOR DEFECTIVE IN THE ENTIRE APARTMENT LOCATED AT APT 1, 1st STORY, 2nd APARTMENT FROM NORTH AT EAST
HPD03/05/2025§ 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT WEST WALL AT CLOSET IN THE 1st ROOM FROM NORTH LOCATED AT APT 1, 1st STORY, 2nd APARTMENT FROM NORTH AT EAST
HPD03/05/2025§ 27-2046.1 HMC: REPAIR OR REPLACE THE CARBON MONOXIDE DETECTING DEVICE(S). DEFECTIVE IN THE ENTIRE APARTMENT LOCATED AT APT 1, 1st STORY, 2nd APARTMENT FROM NORTH AT EAST
HPD03/05/2025§ 329, M/D LAW AND DEPT. RULES AND REGS. PROVIDE A COMPLETED CERTIFICATE OF INSPECTION VISITS IN A PROPER FRAME AT OR NEAR MAILBOXES, BOTTOM EDGE OF FRAME BETWEEN 48-62 INCHES ABOVE FLOOR MISSING AT PUBLIC HALL, 1st STORY
HPD03/05/2025§ 26-1103 ADMIN. CODE: POST AND MAINTAIN A PROPER NOTICE ON WALL OF THE ENTRANCE STORY IN ENGLISH AND SPANISH ON THE AVAILABILITY OF THE AGENCYS HOUSING INFORMATION GUIDE. A SAMPLE NOTICE CAN BE FOUND AT WWW.NYC.GOV/HPD. AT PUBLIC HALL, 1st STORY
HPD04/22/2022§ 27-2005 ADM CODE REPLACE WITH NEW THE BROKEN OR DEFECTIVE MIRROR TO MEDIICINE CABINET IN THE BATHROOM LOCATED AT APT 1, 1st STORY, 2nd APARTMENT FROM NORTH AT EAST
HPD04/22/2022§ 27-2005, 27-2007, 27-2041.1 HMC: REPLACE OR REPAIR THE SELF-CLOSING DOORS THAT IS MISSING OR DEFECTIVE , IN THE ENTRANCE LOCATED AT APT 1, 1st STORY, 2nd APARTMENT FROM NORTH AT EAST
HPD06/30/2015SECTION 27-2005 ADM CODE & 309 M/D LAW ABATE THE NUISANCE CONSISTING OF UNCAPPED GAS SUPPLY LINE AT CEILING IN THE KITCHEN LOCATED AT APT 12, 4th STORY, 1st APARTMENT FROM SOUTH AT WEST
HPD06/30/2015SECTION 27-2046.1 HMC: REPAIR OR REPLACE THE CARBON MONOXIDE DETECTING DEVICE(S). MISSING IN THE ENTIRE APARTMENT LOCATED AT APT 12, 4th STORY, 1st APARTMENT FROM SOUTH AT WEST
HPD06/30/2015SECTION 27-2045 ADM CODE REPAIR OR REPLACE THE SMOKE DETECTOR MISSING IN THE ENTIRE APARTMENT LOCATED AT APT 12, 4th STORY, 1st APARTMENT FROM SOUTH AT WEST
HPD06/30/2015SECTION 27-2070 ADM CODE PROVIDE AN ADEQUATE SUPPLY OF GAS TO THE FIXTURES AT RANGE IN THE KITCHEN LOCATED AT APT 12, 4th STORY, 1st APARTMENT FROM SOUTH AT WEST
HPD06/30/2015SECTION 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR CEILING IN THE BATHROOM LOCATED AT APT 12, 4th STORY, 1st APARTMENT FROM SOUTH AT WEST
ECB03/05/2015WORK DOES NOT CONFORM TO APPROVED CONSTRUCTION DOCUMENTS.(SIDEWALK SHED)NOTED: AT TIME OF INSPECTION THE SIDEWALK SHED IS NOT BUILT ACCORDING TO APPROVED PLANS. SIDEWALK SHED DOES NOT EXTEND 5 FEET POST PROPERTNothing owed — awaiting certificate of correction
ECB01/29/2015WORK DOES NOT CONFORM TO APPROVED CONSTRUCTION DOCUMENTS.NOTED:@ TIME OF INSP.THE SIDEWALK SHED ON EXP.#1 IS NOT BUILT ACCORDING TO APPROVED PLANS.SIDEWALK SHED DOES NOT EXTEND 5'OVER THE ADJ.PROPERTIES.REM:COMNothing owed — awaiting certificate of correction