← Back
BuildNYC
Public elementary, junior or senior high
P.S. 88 Seneca
6085 CATALPA AVENUE · Ridgewood · BIN 4085173
💬 Discuss this project
1908Year Built
5Stories
W1Building Class
R5BZoning
108,169 sfGross Floor Area
1Units
LL97 Covered7 Active Violations 0 unresolved · 7 paperwork only ▸
Public elementary, junior or senior high · Owner of record: NYC Department of Education · 52,650 sf lot · 2.05 FAR built · Flood zone X
Locations of Work
ArchitectureStructuralMechanicalPlumbingEquipment
Names shown beside floors are taken automatically from the text of filed documents and may be incomplete or wrong.
RoofP.S. 88 Seneca, P.S. 088 Queens8p · 2 filings · 17 docs
Floor 5P.S. 088 Queens1 filing · 14 docs
Floor 4P.S. 088 Queens1 filing · 14 docs
Floor 3P.S. 088 Queens1 filing · 14 docs
Floor 2P.S. 088 Queens1 filing · 14 docs
Floor 1P.S. 88 Seneca, P.S. 88 (Q) +114p · 4 filings · 17 docs
CellarP.S. 88 Seneca, P.S. 088 Queens8p · 2 filings · 17 docs
Sub-BasementP.S. 088 Queens1 filing · 14 docs
Site & exteriorP.S. 88 Seneca9p · 2 filings · 17 docs
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
NYC School Construction Authority7707/08/2026
NYC Department of Education507/08/2026
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
NYC School Construction Authority302/02/2026
GC Engineering & Associates105/15/2024
Shenoy Engineering209/13/2023
NYGB305/30/2023
Promina Engineering111/08/2021
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
NYC School Construction Authority303/21/2026
GC Engineering & Associates203/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
Bottom Line ConstructionGeneral Contractor504/09/2026
Bottom Line ConstructionScaffold407/08/2026
S & W Wilson EnterprisesGeneral Contractor107/08/2026
Lawrence's ContractorScaffold107/08/2026
Tristar Plumbing & HeatingPlumbing107/08/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
GC Engineering & Associates1796105/15/2024
Universal Testing and Ins400209/13/2023
KS Engineers7715105/11/2023
Building Lifecycle
All (101)Filed (10)Permit Issued (10)Signed Off (4)Violation (60)Objection (12)Special Inspection (5)
09/22/2026
Signed off — Alteration
SUPPORT OF EXCAVATION TO REMOVE EXISTING 4" AND 6" DRAIN PIPES AND MANHOLE IN CONJUNCTION WITH DOB BIS JOB#421901188. NO CHANGE IN USE, OCCUPANCY, OR EGRESS UNDER THIS APPLICATION.
Q00870474-I1
04/14/2026
Objection resolved — Addressed
04/07/2026
Permit issued — Support of Excavation
Q00870474-I1-SE
04/02/2026
Objection resolved — Addressed
03/26/2026
Objection resolved — Addressed
03/05/2026
Violation issued (ECB, open)
Construction
03/05/2026
Violation issued (ECB, open)
Construction
03/05/2026
Violation issued (ECB, open)
Construction
03/05/2026
Violation issued (ECB, open)
Construction
02/05/2026
Signed off — Alteration
INSTALLATION OF TEMPORARY CONSTRUCTION FENCE IN CONJUNCTION WITH JOB # 421901188
Q00855768-I1
02/05/2026
Objection raised — Other
02/05/2026
Objection raised — Other
02/05/2026
Objection raised — Admin
02/02/2026
Filed — Alteration
REMOVE AND REPLACE EXISTING ROOFING SYSTEMS WITH A NEW LINER. REMOVE AND REPLACE BROKEN BRICKS THROUGHOUT AND MASONRY REPAIRS. UPGRADE PLAY YARD AND VEGETATION THROUGHOUT THE PROPERTY.
Q01296086-S2
02/02/2026
Filed — Alteration
REMOVE AND REPLACE EXISTING ROOFING SYSTEMS WITH A NEW LINER. REMOVE AND REPLACE BROKEN BRICKS THROUGHOUT AND MASONRY REPAIRS. UPGRADE PLAY YARD AND VEGETATION THROUGHOUT THE PROPERTY.
Q01296086-S1
01/30/2026
Filed — Alteration
REMOVE AND REPLACE EXISTING ROOFING SYSTEMS WITH A NEW LINER. REMOVE AND REPLACE BROKEN BRICKS THROUGHOUT AND MASONRY REPAIRS. UPGRADE PLAY YARD AND VEGETATION THROUGHOUT THE PROPERTY.
Q01296086-I1
01/29/2026
Special inspection requirement — Fire-Resistant Penetrations and Joints
01/29/2026
Special inspection requirement — Post-installed Anchors
12/17/2025
Special inspection requirement — Mechanical Systems
12/17/2025
Special inspection requirement — Final
11/28/2025
Permit issued — Construction Fence
Q00855768-I1-FN
05/30/2025
Signed off — Alteration
Installation of Temporary Construction Fence.
Q00626539-I1
03/03/2025
Violation issued (ECB, closed)
Construction
03/03/2025
Violation issued (ECB, open)
Construction
03/03/2025
Violation issued (ECB, open)
Construction
03/03/2025
Violation issued (ECB, open)
Construction
11/01/2024
Permit issued — Construction Fence
Q00855768-I1-FN
08/07/2024
Signed off — Alteration
REPLACEMENT OF AIR COOLED CHILLERS AND WATER PUMPS
Q01023507-I1
06/18/2024
Permit issued — Mechanical Systems
Q01023507-I1-MS
05/15/2024
Filed — Alteration
REPLACEMENT OF AIR COOLED CHILLERS AND WATER PUMPS
Q01023507-I1
03/07/2024
Violation issued (ECB, closed)
Construction
12/07/2023
Permit issued — Plumbing
Q00654264-I1-PL
09/21/2023
Permit issued — Support of Excavation
Q00870474-I1-SE
09/20/2023
Permit issued — Construction Fence
Q00855768-I1-FN
09/13/2023
Filed — Alteration
REMOVE AND REPLACE SECTION OF GAS PIPING SERVING HOT WATER HEATERS AND PROVIDE GAS SOLENOID VALVE.
Q00654264-P1
09/13/2023
Special inspection requirement — Post-installed Anchors
NELSON LOPEZ
07/12/2023
Permit issued — Support of Excavation
Q00870474-I1-SE
06/01/2023
Objection resolved — Addressed
05/31/2023
Objection raised — Other
05/30/2023
Filed — Alteration
INSTALLATION OF TEMPORARY CONSTRUCTION FENCE IN CONJUNCTION WITH JOB # 421901188
Q00855768-P1
05/15/2023
Objection raised — Other
05/15/2023
Objection resolved — Addressed
05/11/2023
Filed — Alteration
SUPPORT OF EXCAVATION TO REMOVE EXISTING 4" AND 6" DRAIN PIPES AND MANHOLE IN CONJUNCTION WITH DOB BIS JOB#421901188. NO CHANGE IN USE, OCCUPANCY, OR EGRESS UNDER THIS APPLICATION.
Q00870474-I1
05/01/2023
Permit issued — Construction Fence
Q00855768-I1-FN
04/12/2023
Filed — Alteration
INSTALLATION OF TEMPORARY CONSTRUCTION FENCE IN CONJUNCTION WITH JOB # 421901188
Q00855768-I1
02/18/2022
Violation issued (ECB, closed)
Construction
02/18/2022
Violation issued (ECB, closed)
Construction
01/07/2022
Objection raised — Other
01/07/2022
Objection resolved — Addressed
12/29/2021
Filed — Alteration
REMOVE AND REPLACE SECTION OF GAS PIPING SERVING HOT WATER HEATERS AND PROVIDE GAS SOLENOID VALVE.
Q00654264-I1
12/03/2021
Permit issued — Construction Fence
Q00626539-I1-FN
11/08/2021
Filed — Alteration
Installation of Temporary Construction Fence.
Q00626539-I1
06/11/2021
Violation issued (ECB, closed)
Construction
05/29/2020
Violation issued (ECB, closed)
Construction
05/29/2020
Violation issued (ECB, closed)
Construction
05/29/2020
Violation issued (ECB, closed)
Construction
09/06/2019
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
08/23/2019
Violation issued (ECB, closed)
Construction
08/23/2019
Violation issued (ECB, closed)
Construction
08/23/2019
Violation issued (ECB, closed)
Construction
Latest 60 of 101 events.
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWSupport of ExcavationSigned-offBottom Line Construction04/07/2026
DOB NOWConstruction FenceSigned-offBottom Line Construction11/28/2025
DOB NOWConstruction FenceSigned-offBottom Line Construction11/01/2024
DOB NOWMechanical SystemsSigned-offS & W Wilson Enterprises06/18/2024
DOB NOWPlumbingPermit IssuedTristar Plumbing & Heating12/07/2023
DOB NOWSupport of ExcavationSigned-offBottom Line Construction09/21/2023
DOB NOWConstruction FenceSigned-offBottom Line Construction09/20/2023
DOB NOWSupport of ExcavationSigned-offBottom Line Construction07/12/2023
DOB NOWConstruction FenceSigned-offBottom Line Construction05/01/2023
DOB NOWConstruction FenceSigned-offLawrence's Contractor12/03/2021
BISOTISSUEDBottom Line Construction12/03/2025
BISPLISSUEDVarsity Plumbing and Heating08/11/2025
BISOTISSUEDBottom Line Construction11/08/2024
BISPLISSUEDVarsity Plumbing and Heating08/14/2024
BISOTISSUEDBottom Line Construction01/04/2024
BISMHISSUEDLawrence's Contractor11/09/2023
BISPLISSUEDVarsity Plumbing and Heating08/17/2023
BISOTISSUEDBottom Line Construction07/12/2023
BISMHISSUEDLawrence's Contractor12/02/2021
BISMHISSUEDLawrence's Contractor08/31/2021
BISOTISSUEDS & W Wilson Enterprises06/11/2019
BISMHISSUEDACS System Associates03/11/2017
BISOTISSUEDTechnico Construction03/08/2017
BISOTISSUEDTechnico Construction03/06/2017
BISMHISSUEDACS System Associates03/10/2016
BISOTISSUEDTechnico Construction02/26/2016
BISPLISSUEDEagle 1 Mechanical02/23/2016
BISMHISSUEDACS System Associates04/30/2015
BISOTISSUEDTechnico Construction02/18/2015
BISOTISSUEDTechnico Construction02/18/2015
BISEQISSUEDTechnico Construction02/18/2015
BISPLISSUEDEagle 1 Mechanical02/09/2015
BISEQRE-ISSUEDRoma Scaffolding02/05/2015
BISEQISSUEDRoma Scaffolding02/05/2015
BISMHISSUEDACS System Associates03/27/2014
BISEQISSUEDTechnico Construction02/24/2014
BISOTISSUEDTechnico Construction02/24/2014
BISOTISSUEDTechnico Construction02/24/2014
BISEQISSUEDRoma Scaffolding02/04/2014
BISEQISSUEDRoma Scaffolding02/04/2014
+ 20 more permits on file
1 project · most recent 09/13/2023
Gas
FiledStatusContractorScope
09/13/2023Permit IssuedTristar Plumbing & HeatingGas
15 projects · most recent 08/12/2026
General Wiring
FiledStatusContractorScope
08/12/2026CompleteA & S Electric—
02/26/2026CompleteA & S Electric—
01/20/2026CompleteA & S Electric—
08/07/2025CompleteGemini Electric Co—
03/12/2024CompletePrince ElectricGeneral Wiring
01/23/2024CompleteJames F. Volpe ElectricalGeneral Wiring
12/21/2023CompleteSpice Electric CompanyGeneral Wiring
08/23/2022CompleteTitan Electrical & Elev Contracting—
07/20/2022CompleteMac Fhionnghaile & SonsGeneral Wiring
08/10/2021CompleteG Energy Soltn and Services IGeneral Wiring
07/14/2021Permit IssuedAbm ElectricGeneral Wiring
09/28/2020Permit IssuedIag ElectricGeneral Wiring
08/12/2020Permit IssuedA & S ElectricGeneral Wiring
04/05/2019Permit IssuedAll American ElectricalGeneral Wiring
03/15/2019CompleteCharan Electrical Enterp's—
1 project · most recent 05/11/2023
FiledStatusContractorScope
05/11/2023Signed-offBottom Line Construction1 scope_items
▾Special Inspection Requirements (DOB NOW) — 5
DateRequirementInspectorRole
01/29/2026Fire-Resistant Penetrations and Joints—special
01/29/2026Post-installed Anchors—special
12/17/2025Mechanical Systems—special
12/17/2025Final—progress
09/13/2023Post-installed AnchorsNELSON LOPEZspecial
▾Tenants in the building
TenantSpaceFloorsRenovation projects
P.S. 088 QueensEducationCellar, Sub-basement, Floors 1–5, Roof
Project Q01296086 Alteration · Approved · 01/30/2026
P.S. 88 SenecaEducationCellar, Floor 1, Roof
Project Q01023507 Alteration · LOC Issued · 05/15/2024
Project Q00870474 Alteration · LOC Issued · 05/11/2023
Project Q00855768 Alteration · LOC Issued · 04/12/2023
Project Q00654264 Alteration · Permit Entire · 12/29/2021
P.S. 88 (Q)EducationFloor 1
Project Q00626539 Alteration · LOC Issued · 11/08/2021
Names are taken automatically from the text of each project’s filed documents (title blocks and cover sheets) and screened to exclude owners, landlords and designers. They may be incomplete or wrong; check the filing.
▾Documents — 77 on file (BIS + DOB NOW)
▸Plans & Drawings10
▸DOB NOWPlans/Sketch10
08/27/2026Q00626539-I1Request digital key ↗
08/24/2026Q00855768-I1Request digital key ↗
08/24/2026Q00654264-P1Request digital key ↗
Showing 3 of 10 on file for this type
▸Applications & Permits3
▸BISWORK PERMIT APPLICATION2
06/26/2019421101097Open ↗
06/26/2019421101097Open ↗
▸BISPLAN / WORK APPROVAL APPLICATION1
02/06/2017421341006Open ↗
▸Zoning, Tax Lot & Property Records1
▸BISTAX LOT: FINAL LOT NUMBER ISSUED1
02/06/2017421341006Open ↗
▸Seals & Professional Certifications13
▸DOB NOWDPL-1: Design Professional Seal & Signature10
08/27/2026Q00626539-I1Open ↗
08/24/2026Q00654264-I1Open ↗
08/24/2026Q00654264-P1Open ↗
Showing 3 of 10 on file for this type
▸BISTECHNICAL REPORT: RESPONSIBILITY/CERTIFICATION2
06/26/2019421101097Open ↗
02/06/2017421341006Open ↗
▸DOB NOWSpecial Inspector Seal & Signature1
08/23/2026Q00654264-I1Open ↗
▸Safety & Tenant Protection3
▸DOB NOWNYCSCA - Approved Site Safety Plans3
08/13/2026Q00855768-P1Open ↗
08/13/2026Q00855768-I1Open ↗
08/13/2026Q00626539-I1Open ↗
▸Environmental & Asbestos5
▸DOB NOWDEP ACP-5: Asbestos Assessment Report3
08/24/2026Q00654264-P1Open ↗
08/22/2026Q01023507-I1Open ↗
08/14/2026Q00654264-I1Open ↗
▸BISASBESTOS: CERTIFICATION (DEP ACP5)2
06/26/2019421101097Open ↗
02/06/2017421341006Open ↗
▸Energy Compliance2
▸BISTECHNICAL REPORT: ENERGY CODE PROGRESS INSPS1
06/26/2019421101097Open ↗
▸DOB NOWPreliminary Commissioning Report Certification1
08/13/2026Q01023507-I1Open ↗
▸Approvals, Objections & Sign-offs24
▸DOB NOWFee Exempt Supporting Document - DOF ACRIS report or BIB letter10
08/13/2026Q00654264-P1Open ↗
08/13/2026Q00626539-I1Open ↗
08/13/2026Q01296086-I1Open ↗
Showing 3 of 10 on file for this type
▸DOB NOWDesign Commission Approval City Owned (Exterior Work)10
08/13/2026Q01296086-S2Open ↗
08/13/2026Q00626539-I1Open ↗
08/13/2026Q01296086-I1Open ↗
Showing 3 of 10 on file for this type
▸DOB NOWDesign Commission Sign Off City Owned (Exterior Work)3
08/13/2026Q01296086-S2Open ↗
08/13/2026Q00855768-I1Open ↗
08/13/2026Q01023507-I1Open ↗
▸BISADMINISTRATIVE OBJECTIONS1
02/06/2017421341006Open ↗
▸Cost, Insurance & Ownership1
▸BISCOST AFFIDAVIT1
02/06/2017421341006Open ↗
▸Filing & Intake Forms1
▸BISEFILING COVER SHEET1
02/06/2017421341006Open ↗
▸Other Documents14
▸DOB NOWNYCSCA - BCC Plan Examination Transmittal9
08/13/2026Q00855768-P1Open ↗
08/13/2026Q00855768-I1Open ↗
08/13/2026Q00870474-I1Open ↗
Showing 3 of 9 on file for this type
▸DOB NOWProof of Historic Building3
08/13/2026Q01296086-I1Open ↗
08/13/2026Q00654264-I1Open ↗
08/13/2026Q00654264-P1Open ↗
▸DOB NOWAdjoining Owners Notification1
08/13/2026Q00870474-I1Open ↗
▸DOB NOWNYCSCA Exhibit 21
08/13/2026Q00855768-I1Open ↗