← Back
BuildNYC
Office with commercial, 1-6 stories
Interdisciplinary Cntr - Springfield
61-58 SPRINGFIELD BOULEVARD · BIN 4162215
💬 Discuss this project
1991Year Built
2Stories
O5Building Class
R4Zoning
—Gross Floor Area
4Units
0 Active Violations 4 old, status unconfirmed ▸FDNY Report ↗
Office with commercial, 1-6 stories · Owner of record: Jackson 13-Lee 74 · 1.74 FAR built · Flood zone X
Locations of Work
ArchitectureStructuralMechanicalPlumbingFire Protection
Names shown beside floors are taken automatically from the text of filed documents and may be incomplete or wrong.
Permit Issued — active, not yet Signed-off
Floor 1Metro Franchising Commissary LLCUnder Construction24p · 1 filing · 17 docs
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
Jacaroga1403/21/2026
Jackson 13-Lee 74203/22/2026
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
Zelta Design310/01/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
Michelle KuoGeneral Contractor108/18/2026
Full Capacity FireFire Protection109/18/2026
Tri State Plumbing & HeatingPlumbing109/19/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
Wavic Engineering1733210/01/2026
Zelta Inspection7764108/10/2026
Building Lifecycle
All (69)Filed (3)Permit Issued (3)Violation (46)Inspection (1)Special Inspection (16)
10/01/2026
Filed — Alteration
PROPOSED INTERIOR RENOVATION AT EXISTING COMMERCIAL SPACE WITH NEW PARTITIONS & FINISHES AS PER PLAN. NO CHANGE IN USE, EGRESS AND OCCUPANCY.
Q01441758-P1
09/30/2026
Special inspection requirement — Sprinkler Systems
DARIUSZ LUCZAK
09/23/2026
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Roughing
Certified
View inspection ↗
09/18/2026
Permit issued — Plumbing
Q01441758-S1-PL
09/17/2026
Permit issued — Plumbing
Q01441758-S1-EW-SP
08/17/2026
Permit issued — General Construction
Q01441758-I1-GC-CX
08/10/2026
Filed — Alteration
PROPOSED INTERIOR RENOVATION AT EXISTING COMMERCIAL SPACE WITH NEW PARTITIONS & FINISHES AS PER PLAN. NO CHANGE IN USE, EGRESS AND OCCUPANCY.
Q01441758-I1
08/10/2026
Filed — Alteration
PROPOSED INTERIOR RENOVATION AT EXISTING COMMERCIAL SPACE WITH NEW PARTITIONS & FINISHES AS PER PLAN. NO CHANGE IN USE, EGRESS AND OCCUPANCY.
Q01441758-S1
08/10/2026
Special inspection requirement — Insulation placement and R values
ERIK LIEPINS
08/05/2026
Special inspection requirement — Final
ERIK LIEPINS
08/05/2026
Special inspection requirement — Energy Code Compliance Inspections
ERIK LIEPINS
08/05/2026
Special inspection requirement — Duct leakage testing, insulation and design
ERIK LIEPINS
08/05/2026
Special inspection requirement — Interior lighting power
ERIK LIEPINS
08/05/2026
Special inspection requirement — Exterior lighting power
ERIK LIEPINS
08/05/2026
Special inspection requirement — HVAC-R and service water heating equipment
ERIK LIEPINS
08/05/2026
Special inspection requirement — Fire-Resistant Penetrations and Joints
ERIK LIEPINS
08/05/2026
Special inspection requirement — HVAC-R and service water heating system controls
ERIK LIEPINS
08/05/2026
Special inspection requirement — HVAC-R and service water piping design and insulation
ERIK LIEPINS
08/05/2026
Special inspection requirement — Lighting controls
ERIK LIEPINS
08/05/2026
Special inspection requirement — Maintenance information
ERIK LIEPINS
08/05/2026
Special inspection requirement — Sprinkler Systems
08/05/2026
Special inspection requirement — Fenestration areas
ERIK LIEPINS
08/05/2026
Special inspection requirement — Mechanical Systems
ERIK LIEPINS
08/14/2025
Violation issued (FDNY_NOV, closed)
08/14/2025
Violation issued (FDNY_NOV, closed)
05/03/2024
Violation issued (FDNY_NOV, closed)
09/12/2022
Violation issued (FDNY_NOV, closed)
05/24/2021
Violation issued (ECB, closed)
Elevators
09/02/2020
Violation issued (DOB, closed)
V*-DOB VIOLATION - Resolved
02/25/2020
Violation issued (FDNY_NOV, closed)
02/02/2020
Violation issued (DOB, open)
V-DOB VIOLATION - ACTIVE
11/02/2019
Violation issued (DOB, open)
V-DOB VIOLATION - ACTIVE
09/06/2019
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
08/02/2019
Violation issued (DOB, open)
V-DOB VIOLATION - ACTIVE
06/20/2019
Violation issued (ECB, closed)
Elevators
05/02/2019
Violation issued (DOB, open)
V-DOB VIOLATION - ACTIVE
06/08/2017
Violation issued (DOB, closed)
V*-DOB VIOLATION - Resolved
01/03/2017
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
11/14/2016
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
07/28/2016
Violation issued (DOB, closed)
V*-DOB VIOLATION - Resolved
12/05/2014
Violation issued (DOB, closed)
V*-DOB VIOLATION - Resolved
03/31/2014
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
09/17/2013
Violation issued (DOB, closed)
V*-DOB VIOLATION - Resolved
12/02/2010
Violation issued (DOB, closed)
V-DOB VIOLATION - ACTIVE
12/02/2010
Violation issued (DOB, closed)
V*-DOB VIOLATION - Resolved
02/03/2010
Violation issued (DOB, closed)
V*-DOB VIOLATION - Resolved
09/04/2008
Violation issued (DOB, closed)
V*-DOB VIOLATION - Resolved
10/03/2007
Violation issued (DOB, closed)
V*-DOB VIOLATION - Resolved
10/27/2006
Violation issued (DOB, closed)
V*-DOB VIOLATION - Resolved
03/30/2004
Violation issued (DOB, closed)
V*-DOB VIOLATION - Resolved
01/22/2003
Violation issued (DOB, closed)
V*-DOB VIOLATION - Resolved
10/04/2001
Violation issued (ECB, closed)
Construction
03/08/2001
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
01/27/2000
Violation issued (ECB, closed)
Construction
01/27/2000
Violation issued (ECB, closed)
Construction
01/24/2000
Violation issued (ECB, closed)
Construction
01/24/2000
Violation issued (ECB, closed)
Construction
01/06/1998
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
01/13/1997
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
01/13/1997
Violation issued (DOB, closed)
V-DOB VIOLATION - ACTIVE
Latest 60 of 69 events.
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWPlumbingPermit IssuedTri State Plumbing & Heating09/18/2026
DOB NOWSprinklersPermit IssuedFull Capacity Fire09/17/2026
DOB NOWGeneral ConstructionPermit IssuedMichelle Kuo08/17/2026
BIS—ISSUEDTutor Time03/28/2011
BISOTISSUEDNathanson Construction09/15/2009
BISPLISSUEDPlumbing & Heating Doctor02/07/2007
BISFPISSUEDNew York Business Fire System01/25/2007
BISMHISSUEDTotal Design Solution01/05/2007
BISPLISSUEDSchumacher & Farley P & H09/19/2006
BISOTISSUEDShahzad Bro08/22/2006
BIS—ISSUEDGrace Design & Consulting07/11/2005
BIS—ISSUEDMontana Electric Deco07/08/2005
BISFPISSUEDNew York Business Fire System05/26/2005
BISPLISSUEDPlumbing & Heating Doctor05/24/2005
BISOTISSUEDGrace Design Consulting04/19/2005
BISEQISSUEDGrace Design Consulting04/19/2005
BISOTISSUEDIntrepid Development & Construction05/21/2002
BIS—ISSUEDParker Service Industries04/30/2002
BIS—ISSUEDParker Service Industries04/30/2002
BISOTISSUEDNational Maintenance04/30/2002
BISOTISSUEDArken02/28/2002
BISPLISSUEDAriana Contracting01/02/2002
BIS—ISSUEDInterboro Sign & Maintenace08/13/2001
BISCCISSUEDEtna Maintenance03/23/2001
BISEQISSUEDPerimeter Bridge, Scaffold Co03/27/2000
BISEQISSUEDPerimeter Bridge, Scaffold Co02/08/2000
BISPLISSUEDOrbit Plumbing & Heating02/07/2000
BIS—ISSUEDMarjan Co01/25/2000
BISEQISSUEDMarjan Co01/24/2000
BISEQISSUEDPerimeter Bridge, Scaffold Co12/10/1999
BISOTISSUEDSign Artistry10/09/1997
BISPLISSUEDBronze Plumbing and Heating03/14/1995
BIS—ISSUEDDayton Construction02/23/1995
BIS—RE-ISSUEDDayton Construction Co08/10/1992
BIS—ISSUEDDayton Consturction03/11/1992
BIS—RE-ISSUEDB & G Industries08/16/1991
BIS—ISSUEDB & G Industries08/16/1991
BIS—ISSUEDB & G Industries08/16/1991
BIS—ISSUEDB & G Industries08/16/1991
BIS—ISSUEDB & G Industries08/16/1991
+ 7 more permits on file
1 project · most recent 10/01/2026
Heating and Air Conditioning Systems
FiledStatusContractorScopeMake / Model / Capacity
10/01/2026Permit IssuedMichelle KuoHeating and Air Conditioning Systems
Heat / Cool
Multiaqua MHQWW-18-H-3 19,920 BTU · Fan Coil Indoor ×1
1 project · most recent 10/01/2026
FiledStatusContractorScope
10/01/2026Permit IssuedFull Capacity Fire—
1 project · most recent 10/01/2026
Water/Sanitary
FiledStatusContractorScope
10/01/2026Permit IssuedDW PlumbingWater/Sanitary
▾Field Inspections (DOB CAP) — 1
DateTypeResultReport
09/23/2026Certified Water and Sanitary-WS-Sanitary Piping-RoughingCertifiedView ↗
▾Special Inspection Requirements (DOB NOW) — 16
DateRequirementInspectorRole
09/30/2026Sprinkler SystemsDARIUSZ LUCZAKspecial
08/10/2026Insulation placement and R valuesERIK LIEPINSenergy_progress
08/05/2026FinalERIK LIEPINSprogress
08/05/2026Energy Code Compliance InspectionsERIK LIEPINSprogress
08/05/2026Duct leakage testing, insulation and designERIK LIEPINSenergy_progress
08/05/2026Interior lighting powerERIK LIEPINSenergy_progress
08/05/2026Exterior lighting powerERIK LIEPINSenergy_progress
08/05/2026HVAC-R and service water heating equipmentERIK LIEPINSenergy_progress
08/05/2026Fire-Resistant Penetrations and JointsERIK LIEPINSspecial
08/05/2026HVAC-R and service water heating system controlsERIK LIEPINSenergy_progress
08/05/2026HVAC-R and service water piping design and insulationERIK LIEPINSenergy_progress
08/05/2026Lighting controlsERIK LIEPINSenergy_progress
08/05/2026Maintenance informationERIK LIEPINSenergy_progress
08/05/2026Sprinkler Systems—special
08/05/2026Fenestration areasERIK LIEPINSenergy_progress
08/05/2026Mechanical SystemsERIK LIEPINSspecial
▾Documents — 74 on file (BIS + DOB NOW)
▸Plans & Drawings2
▸DOB NOWPlans/Sketch2
08/16/2026Q01441758-S1Request digital key ↗
08/16/2026Q01441758-I1Request digital key ↗
▸Applications & Permits12
▸BISPLAN / WORK APPROVAL APPLICATION4
12/30/2013420849666Open ↗
03/07/2011420329193Open ↗
04/30/2010420075064Open ↗
Showing 3 of 4 on file for this type
▸BISWORK PERMIT APPLICATION4
03/30/2011420329193Open ↗
11/05/2009420075064Open ↗
09/15/2009420075064Open ↗
Showing 3 of 4 on file for this type
▸BISNon-Directive 14 Construction Sign Off Including Sign Applications2
01/31/2015420849666Open ↗
06/25/2010420075064Open ↗
▸BISPLACE OF ASSEMBLY1
09/05/2013420849666Open ↗
▸BISCERTIFICATE OF OCCUPANCY: APPLICATION1
04/02/2011420329193Open ↗
▸Zoning, Tax Lot & Property Records1
▸BISTAX LOT- TENTATIVE LOT NUMBER ISSUED1
04/15/2011420329193Open ↗
▸Seals & Professional Certifications25
▸BISTECHNICAL REPORT: RESPONSIBILITY/CERTIFICATION8
01/31/2015420849666Open ↗
11/10/2014420849666Open ↗
09/05/2013420849666Open ↗
Showing 3 of 8 on file for this type
▸DOB NOWDPL-1: Design Professional Seal & Signature4
10/04/2026Q01441758-P1Open ↗
10/04/2026Q01441758-P2Open ↗
08/16/2026Q01441758-S1Open ↗
Showing 3 of 4 on file for this type
▸DOB NOWProgress Inspector Seal & Signature4
10/04/2026Q01441758-P2Open ↗
10/04/2026Q01441758-P2Open ↗
08/23/2026Q01441758-I1Open ↗
Showing 3 of 4 on file for this type
▸BISProfessional and Owner Certification (POC3)3
03/07/2011420329193Open ↗
03/07/2011420329193Open ↗
03/07/2011420329193Open ↗
▸DOB NOWSpecial Inspector Seal & Signature3
10/04/2026Q01441758-P1Open ↗
10/04/2026Q01441758-P2Open ↗
08/23/2026Q01441758-I1Open ↗
▸BISPROFESSIONAL CERTIFIED CHECKLIST2
03/07/2011420329193Open ↗
09/03/2009420075064Open ↗
▸BISPROFESSIONAL CERTIFICATION STATEMENT FORM1
09/03/2009420075064Open ↗
▸Trade Schedules & Equipment6
▸BISEQUIPMENT USE APPLICATION/PERMIT4
06/26/2010420075064Open ↗
06/26/2010420075064Open ↗
06/25/2010420075064Open ↗
Showing 3 of 4 on file for this type
▸BISSCHEDULE B - PLUMBING1
09/03/2009420075064Open ↗
▸BISSELF-CERT PLUMBING NOTICE1
11/16/2009420075064Open ↗
▸Safety & Tenant Protection3
▸BISSTREET TREE CHECKLIST2
03/07/2011420329193Open ↗
09/03/2009420075064Open ↗
▸BISST-1 Street Tree Checklist1
03/31/2011420329193Open ↗
▸Environmental & Asbestos7
▸DOB NOWDEP ACP-5: Asbestos Assessment Report4
10/04/2026Q01441758-P1Open ↗
10/04/2026Q01441758-P2Open ↗
08/16/2026Q01441758-I1Open ↗
Showing 3 of 4 on file for this type
▸BISASBESTOS EXEMPTION CERTIFICATION LETTER2
09/05/2013420849666Open ↗
03/07/2011420329193Open ↗
▸BISTHIS IS 'NOT AN ASBESTOS PROJECT'1
09/03/2009420075064Open ↗
▸Energy Compliance1
▸BISTECHNICAL REPORT: ENERGY CODE PROGRESS INSPS1
09/05/2013420849666Open ↗
▸Approvals, Objections & Sign-offs8
▸BISLETTERS - SUPPORTING DOCUMENTATION3
01/31/2015420849666Open ↗
01/31/2015420849666Open ↗
06/25/2010420075064Open ↗
▸BISCERTIFICATE OF OCCUPANCY/LOC: REQUEST2
05/26/2011420329193Open ↗
06/25/2010420075064Open ↗
▸BISADMINISTRATIVE OBJECTIONS2
03/07/2011420329193Open ↗
09/03/2009420075064Open ↗
▸BISSCHEDULE A - OCCUPANCY / USE1
05/19/2011420329193Open ↗
▸Cost, Insurance & Ownership4
▸BISCOST AFFIDAVIT4
05/11/2011420329193Open ↗
03/31/2011420329193Open ↗
06/25/2010420075064Open ↗
Showing 3 of 4 on file for this type
▸Filing & Intake Forms4
▸BISEFILING COVER SHEET2
03/07/2011420329193Open ↗
09/03/2009420075064Open ↗
▸BISADDITIONAL INFORMATION2
09/24/2014420849666Open ↗
04/22/2011420329193Open ↗
▸Other Documents1
▸BISPLOT DIAGRAM1
03/07/2011420329193Open ↗