← Back
Two family frame
61-71 56 STREET
QUEENS · BIN 4059503
💬 Discuss this project
1930Year Built
2Stories
B2Building Class
R4Zoning
1,800 sfGross Floor Area
2Units
0 Open Violations
Two family frame · 2,200 sf lot · 0.82 FAR built · Flood zone X
Locations of Work
ArchitectureElectricalPlumbing
Roof4p · 2 filings · 16 docs
Cellar4p · 1 filing · 4 docs
▾Sales History (ACRIS)
DatePriceUnitSeller → Buyer$/sf
04/11/2016$800K—— → —$444/sf building
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
TOM PETERSEN ARCHITECT, LLC209/24/2024
GRUPO DESIGN106/19/2020
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
SURF CLEAN ENERGY403/21/2026
CARLOS RAMIREZ103/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
SURF CLEAN ENERGY INCGeneral Contractor407/08/2026
AMPACITY ELECTRICAL INCElectrical103/22/2026
L&J PLG & HTG CO OF NY INPlumbing107/08/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
THOMAS PETERSEN ARCHITECT7854209/24/2024
GIOVANNI ZAPATA R.A.3882106/19/2020
Building Lifecycle
All (27)Filed (3)Permit Issued (3)Violation (3)Objection (8)Special Inspection (10)
10/10/2024
Permit issued — Solar
Q01116547-I1-SL
10/08/2024
Permit issued — Solar
Q01116613-I1-SL
09/24/2024
Filed — Alteration
Q01116613-I1
09/24/2024
Filed — Alteration
Q01116547-I1
09/24/2024
Special inspection requirement — Fire-Resistant Penetrations and Joints
TOM PETERSEN
09/24/2024
Special inspection requirement — Structural Stability – Alterations of existing buildings
TOM PETERSEN
09/24/2024
Special inspection requirement — Energy Code Compliance Inspections
TOM PETERSEN
09/24/2024
Special inspection requirement — Final
TOM PETERSEN
09/24/2024
Special inspection requirement — Air barrier - visual inspection
TOM PETERSEN
09/24/2024
Special inspection requirement — Fire-Resistant Penetrations and Joints
TOM PETERSEN
09/24/2024
Special inspection requirement — Structural Stability – Alterations of existing buildings
TOM PETERSEN
09/24/2024
Special inspection requirement — Energy Code Compliance Inspections
TOM PETERSEN
09/24/2024
Special inspection requirement — Final
TOM PETERSEN
09/24/2024
Special inspection requirement — Air barrier - visual inspection
TOM PETERSEN
10/27/2020
Violation issued (ECB, closed)
Construction
09/02/2020
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
08/26/2020
Permit issued — Plumbing
Q00353219-I1-PL
06/19/2020
Filed — Alteration
PROPOSED TO ADD AND MODIFY THE PLANS ON APPL. Q00353219 ADD EXIST. RANGE ON PLANS AND MODIFY GAS DRY FOR ELECTRIC DRY ON PLANS AND GAS RISER AS PER DOB PLUMBING INSPECTION, PAA NOT ALLOWED AS PER EMAIL OF DOB NOW REQUIRED SUBSEQUENT FILING.
Q00353219-I1
06/19/2020
Objection raised — Inspections
06/19/2020
Objection resolved — Addressed
06/19/2020
Objection raised — Scope
06/19/2020
Objection resolved — Addressed
06/19/2020
Objection raised — Scope
06/19/2020
Objection resolved — Addressed
06/19/2020
Objection raised — Energy
06/19/2020
Objection resolved — Addressed
03/19/2020
Violation issued (ECB, closed)
Construction
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWSolarPermit IssuedSURF CLEAN ENERGY INC10/10/2024
DOB NOWSolarPermit IssuedSURF CLEAN ENERGY INC10/08/2024
DOB NOWPlumbingPermit IssuedL&J PLG & HTG CO OF NY IN08/26/2020
BISOTISSUEDFRANCISCO SOSA, INC07/31/2020
1 project · most recent 06/19/2020
Gas Water/Sanitary
FiledStatusContractorScope
06/19/2020Permit IssuedL&J PLG & HTG CO OF NY INGas, Water/Sanitary
4 projects · most recent 03/11/2025
General Wiring
FiledStatusContractorScope
03/11/2025CompleteAMPACITY ELECTRICAL INC—
01/29/2025Permit IssuedAMPACITY ELECTRICAL INC2 meters
06/15/2024Permit IssuedBERGER QUALITY ELEC'L CON—
06/05/2020CompleteCRESCO ELECTRICAL CORPGeneral Wiring
▾Special Inspection Requirements (DOB NOW) — 10
DateRequirementInspectorRole
09/24/2024Fire-Resistant Penetrations and JointsTOM PETERSENspecial
09/24/2024Structural Stability – Alterations of existing buildingsTOM PETERSENspecial
09/24/2024Energy Code Compliance InspectionsTOM PETERSENprogress
09/24/2024FinalTOM PETERSENprogress
09/24/2024Air barrier - visual inspectionTOM PETERSENenergy_progress
09/24/2024Fire-Resistant Penetrations and JointsTOM PETERSENspecial
09/24/2024Structural Stability – Alterations of existing buildingsTOM PETERSENspecial
09/24/2024Energy Code Compliance InspectionsTOM PETERSENprogress
09/24/2024FinalTOM PETERSENprogress
09/24/2024Air barrier - visual inspectionTOM PETERSENenergy_progress
▾Documents — 43 on file (BIS + DOB NOW)
▸Plans & Drawings4
▸DOB NOWPlans/Sketch3
08/28/2026Q00353219-S1Request digital key ↗
08/21/2026Q01116547-I1Request digital key ↗
08/21/2026Q01116613-I1Request digital key ↗
▸DOB NOWPlans/Sketch - Plumbing Legalization1
08/14/2026Q00353219-I1Request digital key ↗
▸Applications & Permits3
▸BISPLAN / WORK APPROVAL APPLICATION2
12/23/2020440600477Open ↗
06/29/2020440600477Open ↗
▸BISWORK PERMIT APPLICATION1
08/03/2020440600477Open ↗
▸Seals & Professional Certifications16
▸DOB NOWProgress Inspector Seal & Signature6
09/02/2026Q01116547-I1Open ↗
09/02/2026Q01116547-I1Open ↗
09/02/2026Q01116547-I1Open ↗
Showing 3 of 6 on file for this type
▸DOB NOWSpecial Inspector Seal & Signature4
09/02/2026Q01116547-I1Open ↗
09/02/2026Q01116547-I1Open ↗
08/25/2026Q01116613-I1Open ↗
Showing 3 of 4 on file for this type
▸DOB NOWDPL-1: Design Professional Seal & Signature4
08/28/2026Q00353219-I1Open ↗
08/28/2026Q00353219-S1Open ↗
08/21/2026Q01116613-I1Open ↗
Showing 3 of 4 on file for this type
▸BISAPPLICANT OWNER SIGNATURE1
06/29/2020440600477Open ↗
▸BISTECHNICAL REPORT STATEMENT OF RESPONSIBILITY1
06/29/2020440600477Open ↗
▸Safety & Tenant Protection2
▸BISTenant Protection Plan and Notes1
07/07/2020440600477Open ↗
▸DOB NOWTenant Protection Plan1
08/13/2026Q00353219-I1Open ↗
▸Environmental & Asbestos4
▸DOB NOWDEP ACP-5: Asbestos Assessment Report3
08/21/2026Q01116613-I1Open ↗
08/14/2026Q00353219-I1Open ↗
08/13/2026Q01116547-I1Open ↗
▸BISASBESTOS: CERTIFICATION (DEP ACP5)1
06/29/2020440600477Open ↗
▸Energy Compliance4
▸BISTECHNICAL REPORT: ENERGY CODE - RESPONSIBILITY2
03/10/2021440600477Open ↗
06/29/2020440600477Open ↗
▸BISAS-BUILT ENERGY ANALYSIS1
03/10/2021440600477Open ↗
▸BISTECHNICAL REPORT STATEMENT OF RESPONSIBILITY FOR ENERGY CODE PROGRESS INSPECTIONS1
06/29/2020440600477Open ↗
▸Inspections & Test Reports2
▸BISTECHNICAL REPORT: RESPONSIBILITY2
03/10/2021440600477Open ↗
06/29/2020440600477Open ↗
▸Approvals, Objections & Sign-offs1
▸BISCERTIFICATE OF OCCUPANCY/LOC: REQUEST1
03/10/2021440600477Open ↗
▸Cost, Insurance & Ownership2
▸BISCOST AFFIDAVIT2
03/10/2021440600477Open ↗
06/29/2020440600477Open ↗
▸Filing & Intake Forms4
▸BISADDITIONAL INFORMATION2
01/29/2021440600477Open ↗
07/07/2020440600477Open ↗
▸BISEFILING JOB APPLICATION COVER SHEET1
06/29/2020440600477Open ↗
▸BISBOROUGH INTAKE FORM1
08/03/2020440600477Open ↗
▸Other Documents1
▸BISCONSTRUCTION - SUPPORTING DOCUMENTATION1
03/10/2021440600477Open ↗