← Back
Cape Cod
61 LAKELAND ROAD
STATEN ISLAND · Westerleigh-Castleton Corners · BIN 5008949
💬 Discuss this project
1940Year Built
1.75Stories
A0Building Class
R2Zoning
2,123 sfGross Floor Area
1Units
Cape Cod · 6,900 sf lot · 0.31 FAR built · Flood zone X
Locations of Work
No floor-level scope or drawing coverage on file for this building.
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
RONALD D.VICTORIO R.A.101/23/2023
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
TROOST BROS INCGeneral Contractor107/08/2026
Building Lifecycle
All (10)Filed (1)Permit Issued (1)Signed Off (1)Special Inspection (7)
04/28/2023
Signed off — Alteration
Reconstruction of portion of the greenhouse which was previously filed, approved & signed off under application # 500602378. Scope of work to include removal of greenhouse structure and installation of windows & frame roofing system. No change in Fl area.
S08027435-I1
02/24/2023
Permit issued — General Construction
S08027435-I1-GC
01/23/2023
Filed — Alteration
Reconstruction of portion of the greenhouse which was previously filed, approved & signed off under application # 500602378. Scope of work to include removal of greenhouse structure and installation of windows & frame roofing system. No change in Fl area.
S08027435-I1
11/09/2022
Special inspection requirement — Fenestration areas
anthony santoro
11/09/2022
Special inspection requirement — Energy Code Compliance Inspections
anthony santoro
11/09/2022
Special inspection requirement — Fenestration and door U-factor and product ratings
anthony santoro
11/09/2022
Special inspection requirement — Fenestration air leakage
anthony santoro
11/09/2022
Special inspection requirement — Insulation placement and R values
anthony santoro
11/09/2022
Special inspection requirement — Air barrier - visual inspection
anthony santoro
10/25/2022
Special inspection requirement — Final
anthony santoro
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWGeneral ConstructionSigned-offTROOST BROS INC02/24/2023
BISPLISSUEDCHARLES J. DEHART JR P&H12/10/2004
BISOTISSUEDAVID CONSTRUCTION INC09/13/2004
Nothing on file for this building.
▾Special Inspection Requirements (DOB NOW) — 7
DateRequirementInspectorRole
11/09/2022Fenestration areasanthony santoroenergy_progress
11/09/2022Energy Code Compliance Inspectionsanthony santoroprogress
11/09/2022Fenestration and door U-factor and product ratingsanthony santoroenergy_progress
11/09/2022Fenestration air leakageanthony santoroenergy_progress
11/09/2022Insulation placement and R valuesanthony santoroenergy_progress
11/09/2022Air barrier - visual inspectionanthony santoroenergy_progress
10/25/2022Finalanthony santoroprogress
▾Documents — 4 on file (BIS + DOB NOW)
▸Plans & Drawings1
▸DOB NOWPlans/Sketch1
08/23/2026S08027435-I1Request digital key ↗
▸Seals & Professional Certifications3
▸DOB NOWProgress Inspector Seal & Signature2
08/27/2026S08027435-I1Open ↗
08/27/2026S08027435-I1Open ↗
▸DOB NOWDPL-1: Design Professional Seal & Signature1
08/23/2026S08027435-I1Open ↗