← Back
BuildNYC
Banking facility, with or without parking
6117 18TH AVENUE
BROOKLYN · Bensonhurst · BIN 3132461
💬 Discuss this project
1931Year Built
1Stories
K7Building Class
R5Zoning
4,684 sfGross Floor Area
1Units
0 Active ViolationsFDNY Report ↗
Banking facility, with or without parking · Owner of record: Valley National Bank · 2,405 sf lot · 1.95 FAR built · Flood zone X
Locations of Work
ArchitectureMechanicalPlumbingGeneral
Names shown beside floors are taken automatically from the text of filed documents and may be incomplete or wrong.
RoofValley National Bank7p · 1 filing · 20 docs
Site & exteriorValley National Bank1p · 2 filings · 4 docs
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
Valley National Bank1304/09/2026
Andrew Roth & Sons303/21/2026
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
Bazini Engineering401/16/2026
Leon Skvirsky PE208/05/2019
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
Building Brothers403/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
Sound Refrigeration & Airspecialty_contractor204/09/2026
Going Sign & Servicing CoSign hanger207/08/2026
DJCPlumbing207/08/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
Bazini Engineering1808201/16/2026
Building Lifecycle
All (33)Filed (6)Permit Issued (6)Signed Off (3)Violation (10)Inspection (3)Special Inspection (5)
07/02/2026
Inspection — Certified StandPipe-SD-Fixtures-Finish-SD
Certified
View inspection ↗
06/26/2026
Inspection — Certified StandPipe-SD-Piping-Hydrostatic Test
Certified
View inspection ↗
06/02/2026
Signed off — Alteration
REPLACE ONE (1) PACKAGED ROOFTOP HVAC UNIT ON EXISTING ROOF-CURBS WITH NEW CURB ADAPTER AS PER PLANS. NO CHANGE IN USE, EGRESS OR OCCUPANCY.
B01269751-S1
05/19/2026
Signed off — Alteration
REPLACE ONE (1) PACKAGED ROOFTOP HVAC UNIT ON EXISTING ROOF-CURBS WITH NEW CURB ADAPTER AS PER PLANS. NO CHANGE IN USE, EGRESS OR OCCUPANCY.
B01269751-I1
05/19/2026
Signed off — Alteration
REPLACE ONE (1) PACKAGED ROOFTOP HVAC UNIT ON EXISTING ROOF-CURBS WITH NEW CURB ADAPTER AS PER PLANS. NO CHANGE IN USE, EGRESS OR OCCUPANCY.
B01269751-S2
05/13/2026
Inspection — Pass-Final PL - Up to 3 Requested Floors
Pass
View inspection ↗
02/02/2026
Permit issued — Plumbing
B01269751-S3-PL
01/22/2026
Permit issued — Mechanical Systems
B01269751-S2-MS
01/16/2026
Filed — Alteration
REPLACE ONE (1) PACKAGED ROOFTOP HVAC UNIT ON EXISTING ROOF-CURBS WITH NEW CURB ADAPTER AS PER PLANS. NO CHANGE IN USE, EGRESS OR OCCUPANCY.
B01269751-S2
01/16/2026
Filed — Alteration
REPLACE ONE (1) PACKAGED ROOFTOP HVAC UNIT ON EXISTING ROOF-CURBS WITH NEW CURB ADAPTER AS PER PLANS. NO CHANGE IN USE, EGRESS OR OCCUPANCY.
B01269751-S3
11/13/2025
Permit issued — Mechanical Systems
B01269751-I1-MS
11/07/2025
Filed — Alteration
REPLACE ONE (1) PACKAGED ROOFTOP HVAC UNIT ON EXISTING ROOF-CURBS WITH NEW CURB ADAPTER AS PER PLANS. NO CHANGE IN USE, EGRESS OR OCCUPANCY.
B01269751-S1
11/07/2025
Filed — Alteration
REPLACE ONE (1) PACKAGED ROOFTOP HVAC UNIT ON EXISTING ROOF-CURBS WITH NEW CURB ADAPTER AS PER PLANS. NO CHANGE IN USE, EGRESS OR OCCUPANCY.
B01269751-I1
11/07/2025
Permit issued — Plumbing
B01269751-S1-PL
11/07/2025
Special inspection requirement — HVAC-R and service water heating equipment
Joseph Bazini
11/06/2025
Special inspection requirement — Mechanical Systems
Joseph Bazini
11/06/2025
Special inspection requirement — Final
Joseph Bazini
08/11/2025
Special inspection requirement — Mechanical Systems
Joseph Bazini
08/11/2025
Special inspection requirement — Final
Joseph Bazini
08/09/2019
Permit issued — Sign
B00197408-I1-SG
08/07/2019
Permit issued — Sign
B00197427-I1-SG
08/05/2019
Filed — Alteration
B00197427-I1
08/05/2019
Filed — Alteration
B00197408-I1
02/27/2001
Violation issued (DOB, closed)
V-DOB VIOLATION - ACTIVE
02/07/2000
Violation issued (DOB, closed)
V-DOB VIOLATION - ACTIVE
03/16/1999
Violation issued (DOB, closed)
V-DOB VIOLATION - ACTIVE
05/04/1998
Violation issued (DOB, closed)
V-DOB VIOLATION - ACTIVE
09/16/1997
Violation issued (DOB, closed)
V-DOB VIOLATION - ACTIVE
02/10/1997
Violation issued (DOB, closed)
V-DOB VIOLATION - ACTIVE
08/29/1995
Violation issued (DOB, closed)
V-DOB VIOLATION - ACTIVE
06/01/1994
Violation issued (DOB, closed)
V-DOB VIOLATION - ACTIVE
08/16/1993
Violation issued (DOB, closed)
V-DOB VIOLATION - ACTIVE
06/01/1993
Violation issued (DOB, closed)
V-DOB VIOLATION - ACTIVE
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWPlumbingPermit IssuedDJC02/02/2026
DOB NOWMechanical SystemsSigned-offSound Refrigeration & Air01/22/2026
DOB NOWMechanical SystemsSigned-offSound Refrigeration & Air11/13/2025
DOB NOWPlumbingSigned-offDJC11/07/2025
DOB NOWSignPermit IssuedPolsinelli, Henry08/09/2019
DOB NOWSignPermit IssuedPolsinelli, Henry08/07/2019
BISOTISSUEDSalvatore Calcagno Construction03/21/2000
BISOTISSUEDSalvatore Calcagno Construction10/04/1999
1 project · most recent 01/16/2026
Heating and Air Conditioning Systems Ventilation Systems
FiledStatusContractorScopeMake / Model / Capacity
01/16/2026Signed-offSound Refrigeration & AirHeating and Air Conditioning Systems, Ventilation Systems
Heat / Cool
Trane YHK036A3S0H 3 tons · Rooftop Unit ×1
YHK090A3S0H 90,840 BTU · Rooftop Unit ×2
Ventilation
Trane YHK036A3S0H 1,200 CFM · Rooftop Unit ×1
YHK090A3S0H 2,475 CFM · Rooftop Unit ×2
1 project · most recent 01/16/2026
Gas
FiledStatusContractorScope
01/16/2026Permit IssuedDJCGas
▾Field Inspections (DOB CAP) — 3
DateTypeResultReport
07/02/2026Certified StandPipe-SD-Fixtures-Finish-SDCertifiedView ↗
06/26/2026Certified StandPipe-SD-Piping-Hydrostatic TestCertifiedView ↗
05/13/2026Pass-Final PL - Up to 3 Requested FloorsPassView ↗
▾Special Inspection Requirements (DOB NOW) — 5
DateRequirementInspectorRole
11/07/2025HVAC-R and service water heating equipmentJoseph Bazinienergy_progress
11/06/2025Mechanical SystemsJoseph Bazinispecial
11/06/2025FinalJoseph Baziniprogress
08/11/2025Mechanical SystemsJoseph Bazinispecial
08/11/2025FinalJoseph Baziniprogress
▾Tenants in the building
TenantSpaceFloorsRenovation projects
Valley National BankBank / Financial branchRoof
Project B01269751 Alteration · Permit Entire · 11/07/2025
Project B00197408 Alteration · Permit Entire · 08/05/2019
Project B00197427 Alteration · Permit Entire · 08/05/2019
Names are taken automatically from the text of each project’s filed documents (title blocks and cover sheets) and screened to exclude owners, landlords and designers. They may be incomplete or wrong; check the filing.
▾Documents — 24 on file (BIS + DOB NOW)
▸Plans & Drawings7
▸DOB NOWPlans/Sketch5
08/20/2026B01269751-P1Request digital key ↗
08/20/2026B01269751-S3Request digital key ↗
08/20/2026B01269751-S2Request digital key ↗
Showing 3 of 5 on file for this type
▸DOB NOWPlans/Sketch - Sign2
09/02/2026B00197427-I1Request digital key ↗
09/02/2026B00197408-I1Request digital key ↗
▸Seals & Professional Certifications12
▸DOB NOWDPL-1: Design Professional Seal & Signature7
08/20/2026B01269751-P1Open ↗
08/13/2026B01269751-S1Open ↗
08/13/2026B01269751-S3Open ↗
Showing 3 of 7 on file for this type
▸DOB NOWProgress Inspector Seal & Signature3
09/23/2026B01269751-I1Open ↗
09/23/2026B01269751-S2Open ↗
09/23/2026B01269751-I1Open ↗
▸DOB NOWSpecial Inspector Seal & Signature2
09/23/2026B01269751-I1Open ↗
09/23/2026B01269751-S2Open ↗
▸Environmental & Asbestos5
▸DOB NOWDEP ACP-5: Asbestos Assessment Report5
08/20/2026B01269751-P1Open ↗
08/13/2026B01269751-S2Open ↗
08/13/2026B01269751-I1Open ↗
Showing 3 of 5 on file for this type