| Owner | Filings | Most Recent |
|---|---|---|
| KBRR | 8 | 07/08/2026 |
| MES CONSTRUCTION CORP | 5 | 03/22/2026 |
| 4 RISING STAR REALTY LLC | 1 | 03/22/2026 |
| 4 RISING STAR | 1 | 03/21/2026 |
| Date | Price | Unit | Seller → Buyer | $/sf |
|---|---|---|---|---|
| 05/19/2016 | $900K | — | Private party → 4 RISING STAR REALTY LLC | $500/sf building |
| Firm | Filings | Most Recent |
|---|---|---|
| BUILDING ENGINEERING SYSTEMS PLLC | 4 | 09/19/2024 |
| NY BUILDING ASSOCIATES INC | 1 | 05/07/2018 |
| Representative | Filings | Most Recent |
|---|---|---|
| HIGHQUALITY CONSTRUCTION VNW | 2 | 03/21/2026 |
| Firm | Trade | Roles | Most Recent |
|---|---|---|---|
| PETERKIN CONSTRUCTION LLC | General Contractor | 6 | 03/21/2026 |
| KWONG MING ELECTRIC INC | Electrical | 1 | 03/22/2026 |
| MES CONSTRUCTION CORP | Plumbing | 1 | 07/08/2026 |
| UNITECH DESIGN | Scaffold | 1 | 07/08/2026 |
| Agency | License # | Filings | Most Recent |
|---|---|---|---|
| ALL STATE PROPERTY INSPEC | 4288 | 4 | 09/19/2024 |
| NKM ENGINEERING PLLC | 6244 | 1 | 05/07/2018 |
| Source | Work Type | Status | Applicant | Issued |
|---|---|---|---|---|
| DOB NOW | Mechanical Systems | Signed-off | PETERKIN CONSTRUCTION LLC | 06/26/2024 |
| DOB NOW | General Construction | Signed-off | PETERKIN CONSTRUCTION LLC | 03/12/2024 |
| DOB NOW | Plumbing | Signed-off | MES CONSTRUCTION CORP | 04/06/2022 |
| DOB NOW | Sign | Signed-off | UNITECH DESIGN INC | 05/10/2018 |
| BIS | OT | ISSUED | HIGH QUALITY CONSTRUCTION | 12/12/2017 |
| BIS | PL | ISSUED | TOP PLUMBING GROUP,INC | 12/12/2017 |
| BIS | FP | ISSUED | MASTER FIRE SYSTEMS, INC | 09/29/2017 |
| BIS | BL | ISSUED | TOP PLUMBING GROUP,INC | 06/02/2017 |
| BIS | PL | ISSUED | SO PLUMBING & HEATING INC | 08/22/2016 |
| BIS | OT | ISSUED | HIGH QUALITY CONSTRUCTION | 08/22/2016 |
| Filed | Status | Contractor | Scope | Make / Model / Capacity |
|---|---|---|---|---|
| 09/19/2024 | Signed-off | PETERKIN CONSTRUCTION LLC | Heating and Air Conditioning Systems | Heat / Cool Mitsubishi Electric MUZ-FH12NA 12,000 BTU · Condensing Unit ×12 MUZ-FH18NAH 18,000 BTU · Condensing Unit ×6 |
| Filed | Status | Contractor | Scope |
|---|---|---|---|
| 02/08/2022 | Signed-off | MES CONSTRUCTION CORP | Gas |
| Filed | Status | Contractor | Scope |
|---|---|---|---|
| 05/25/2018 | Complete | KWONG MING ELECTRIC INC | General Wiring |
| 05/01/2018 | Permit Issued | KWONG MING ELECTRIC INC | — |
| 02/13/2018 | Complete | KWONG MING ELECTRIC INC | General Wiring |
| Date | Type | Result | Report |
|---|---|---|---|
| 03/06/2025 | Pass-Final General Construction Non-Directive 14 | Pass | View ↗ |
| 03/04/2025 | Fail-Final General Construction Non-Directive 14 | Fail | View ↗ |
| 01/25/2023 | Pass-Final PL - Up to 3 Requested Floors | Pass | View ↗ |
| 01/24/2023 | Pass-Final PL - Up to 3 Requested Floors | Pass | View ↗ |
| 05/07/2022 | Pass-Final PL - Up to 3 Requested Floors | Pass | View ↗ |
| 04/22/2022 | Fail-Final PL - Up to 3 Requested Floors | Fail | View ↗ |
| 04/13/2022 | Certified Gas-Gas-Piping-Roughing | Certified | View ↗ |
| Date | Requirement | Inspector | Role |
|---|---|---|---|
| 09/19/2024 | Fire-Resistance Rated Construction | SEBERT DYER | progress |
| 09/19/2024 | Lighting controls | SEBERT DYER | energy_progress |
| 09/19/2024 | Metering | SEBERT DYER | energy_progress |
| 09/19/2024 | Fire-Resistant Penetrations and Joints | SEBERT DYER | special |
| 09/19/2024 | Mechanical Systems | SEBERT DYER | special |
| 09/19/2024 | Energy Code Compliance Inspections | SEBERT DYER | progress |
| 09/19/2024 | Final | SEBERT DYER | progress |
| 09/19/2024 | Interior lighting power | SEBERT DYER | energy_progress |
| 09/19/2024 | Maintenance information | SEBERT DYER | energy_progress |
| 02/06/2022 | Energy Code Compliance Inspections | SEBERT DYER | progress |
| 02/06/2022 | Fire-Resistant Penetrations and Joints | SEBERT DYER | special |