← Back
Two family converted from one family
613 QUINCY STREET
BROOKLYN · BIN 3044282
💬 Discuss this project
1899Year Built
2Stories
B3Building Class
R6BZoning
2,541 sfGross Floor Area
2Units
0 Open ViolationsFDNY Report ↗
Two family converted from one family · 1,883 sf lot · 1.35 FAR built · Flood zone X
Locations of Work
ArchitectureStructuralMechanical
Floor 228p · 1 filing · 20 docs
Floor 124p · 1 filing · 20 docs
Cellar24p · 1 filing · 20 docs
Basement26p · 1 filing · 20 docs
1 job · most recent 07/06/2022
Ventilation Systems
FiledStatusContractorScopeMake / Model / Capacity
07/06/2022Signed-offPROGETTO GROUP INCVentilation Systems
Ventilation
N/A n/a 50 CFM · Exhaust Fan ×9
1 job · most recent 07/06/2022
Water/Sanitary
FiledStatusContractorScope
07/06/2022Signed-offVILLAGE P & H NY INCWater/Sanitary
3 jobs · most recent 10/19/2021
General Wiring
FiledStatusContractorScope
10/19/2021CompleteBROOKYLN SOLARWORKS, LLC2 meters
10/03/2021CompleteGRAND ELECTRIC , INC.General Wiring
08/20/2021CompleteBROOKYLN SOLARWORKS, LLC—
1 job · most recent 07/06/2022
Steel Concrete
FiledStatusContractorScope
07/06/2022Signed-offVILLAGE P & H NY INCSteel, Concrete
Building Lifecycle
All (49)Filed (6)Permit Issued (6)Violation (1)Inspection (6)Special Inspection (30)
03/28/2023
Inspection — Pass-Final CND-Occupancy Inspection
Pass
View inspection ↗
10/20/2022
Inspection — Pass-Final CND-Occupancy Inspection
Pass
View inspection ↗
10/11/2022
Inspection — No Access-Final CND-Occupancy Inspection
No Access
View inspection ↗
07/29/2022
Inspection — Certified Remove/Cap - work done in accordance with code
Certified
View inspection ↗
07/29/2022
Inspection — Certified Water and Sanitary-WS-Fixtures-Finish
Certified
View inspection ↗
07/28/2022
Permit issued — Plumbing
B00534683-S1-PL
07/11/2022
Special inspection requirement — Fire-Resistant Penetrations and Joints
David Miller
07/11/2022
Special inspection requirement — Energy Code Compliance Inspections
David Miller
07/11/2022
Special inspection requirement — HVAC-R and service water piping design and insulation
David Miller
07/06/2022
Filed — Alteration CO
SELECTIVE MODERATE INTERIOR RENOVATION CONSISTING OF NON LOAD, GWB, TILE WORK, KITCHEN CABINET REPLACEMENT, TRIM, MOLDINGS,COSMETIC FINISHES AS INDICATED. RECONFIGURE EXISTING 2 FAMILY HOME. EXTERIOR WORK TO INCLUDE NON COMBUSTIBLE REAR YARD DECK,DOORS.
B00534683-P2
07/06/2022
Filed — Alteration CO
SELECTIVE MODERATE INTERIOR RENOVATION CONSISTING OF NON LOAD, GWB, TILE WORK, KITCHEN CABINET REPLACEMENT, TRIM, MOLDINGS,COSMETIC FINISHES AS INDICATED. RECONFIGURE EXISTING 2 FAMILY HOME. EXTERIOR WORK TO INCLUDE NON COMBUSTIBLE REAR YARD DECK,DOORS.
B00534683-P3
07/06/2022
Special inspection requirement — HVAC-R and service water piping design and insulation
David Miller
07/06/2022
Special inspection requirement — Energy Code Compliance Inspections
David Miller
07/06/2022
Special inspection requirement — Fire-Resistant Penetrations and Joints
David Miller
07/05/2022
Special inspection requirement — Interior lighting power
David Miller
07/05/2022
Special inspection requirement — Air barrier - visual inspection
David Miller
07/05/2022
Special inspection requirement — Metering
David Miller
07/05/2022
Special inspection requirement — Fire-Resistant Penetrations and Joints
David Miller
07/05/2022
Special inspection requirement — Mechanical Systems
David Miller
07/05/2022
Special inspection requirement — Energy Code Compliance Inspections
David Miller
07/05/2022
Special inspection requirement — Final
David Miller
07/05/2022
Special inspection requirement — Fenestration and door U-factor and product ratings
David Miller
07/05/2022
Special inspection requirement — Permanent certificate
David Miller
02/15/2022
Permit issued — Structural
B00534683-S2-ST
02/15/2022
Permit issued — General Construction
B00534683-I1-GC-CX
12/30/2021
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Roughing
Certified
View inspection ↗
10/15/2021
Permit issued — Plumbing
B00534683-S1-PL
09/22/2021
Permit issued — Structural
B00534683-S2-ST
09/13/2021
Filed — Alteration CO
SELECTIVE MODERATE INTERIOR RENOVATION CONSISTING OF NON LOAD, GWB, TILE WORK, KITCHEN CABINET REPLACEMENT, TRIM, MOLDINGS,COSMETIC FINISHES AS INDICATED. RECONFIGURE EXISTING 2 FAMILY HOME. EXTERIOR WORK TO INCLUDE NON COMBUSTIBLE REAR YARD DECK,DOORS.
B00534683-S2
09/03/2021
Permit issued — Mechanical Systems
B00534683-I1-GC-CX
07/21/2021
Filed — Alteration CO
SELECTIVE MODERATE INTERIOR RENOVATION CONSISTING OF NON LOAD, GWB, TILE WORK, KITCHEN CABINET REPLACEMENT, TRIM, MOLDINGS,COSMETIC FINISHES AS INDICATED. RECONFIGURE EXISTING 2 FAMILY HOME. EXTERIOR WORK TO INCLUDE NON COMBUSTIBLE REAR YARD DECK,DOORS.
B00534683-P1
07/21/2021
Special inspection requirement — Structural Steel - High Strength Bolting
Celin Munoz
07/21/2021
Special inspection requirement — Structural Steel - Welding
Celin Munoz
07/21/2021
Special inspection requirement — Subgrade Inspections
Celin Munoz
07/21/2021
Special inspection requirement — Subsurface Conditions – Fill Placement & In-Place Density
Celin Munoz
07/21/2021
Special inspection requirement — Post-installed Anchors
Celin Munoz
07/21/2021
Special inspection requirement — Final
Celin Munoz
07/21/2021
Special inspection requirement — Structural Steel - Details
Celin Munoz
07/21/2021
Special inspection requirement — Concrete - Cast-In-Place
Celin Munoz
07/21/2021
Special inspection requirement — Structural Stability – Alterations of existing buildings
Celin Munoz
07/20/2021
Special inspection requirement — Fire-Resistant Penetrations and Joints
David Miller
07/20/2021
Special inspection requirement — Interior lighting power
07/20/2021
Special inspection requirement — Permanent certificate
07/20/2021
Special inspection requirement — Fenestration and door U-factor and product ratings
07/20/2021
Special inspection requirement — Metering
07/20/2021
Special inspection requirement — Air barrier - visual inspection
06/30/2021
Filed — Alteration CO
SELECTIVE MODERATE INTERIOR RENOVATION CONSISTING OF NON LOAD, GWB, TILE WORK, KITCHEN CABINET REPLACEMENT, TRIM, MOLDINGS,COSMETIC FINISHES AS INDICATED. RECONFIGURE EXISTING 2 FAMILY HOME. EXTERIOR WORK TO INCLUDE NON COMBUSTIBLE REAR YARD DECK,DOORS.
B00534683-S1
06/18/2021
Filed — Alteration CO
SELECTIVE MODERATE INTERIOR RENOVATION CONSISTING OF NON LOAD, GWB, TILE WORK, KITCHEN CABINET REPLACEMENT, TRIM, MOLDINGS,COSMETIC FINISHES AS INDICATED. RECONFIGURE EXISTING 2 FAMILY HOME. EXTERIOR WORK TO INCLUDE NON COMBUSTIBLE REAR YARD DECK,DOORS.
B00534683-I1
06/27/2005
Violation issued (HPD, closed)
C
▾Sales History (ACRIS)
DatePriceUnitSeller → Buyer$/sf
03/11/2015$880K—— → —$346/sf building
09/16/2014$725K—Private party → 613 QUINCY LLC$285/sf building
▾Design Consultants (Architect / Engineer of Record)
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
PROGETTO GROUP INCGeneral Contractor1203/21/2026
DAVID MILLERElectrical603/21/2026
VILLAGE P & H NY INCPlumbing307/08/2026
L&J PLG & HTG CO OF NY INPlumbing207/08/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
BERGEN STREET STUDIO FOR6988507/06/2022
CELIN MUNOZ CONSULTING EN1064109/13/2021
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWPlumbingSigned-offVILLAGE P & H NY INC07/28/2022
DOB NOWStructuralSigned-offPROGETTO GROUP INC02/15/2022
DOB NOWGeneral ConstructionPermit IssuedPROGETTO GROUP INC02/15/2022
DOB NOWPlumbingSigned-offL&J PLG & HTG CO OF NY IN10/15/2021
DOB NOWStructuralSigned-offPROGETTO GROUP INC09/22/2021
DOB NOWMechanical SystemsPermit IssuedPROGETTO GROUP INC09/03/2021
BISOTISSUEDBROOKLYN SOLARWORKS LLC07/14/2021
BISPLISSUEDNEW YORK STANDARD MECH CORP10/19/2015
BISOTISSUEDTALL BUILDERS LLC06/04/2015
▾Field Inspections (DOB CAP) — 6
DateTypeResultReport
03/28/2023Pass-Final CND-Occupancy InspectionPassView ↗
10/20/2022Pass-Final CND-Occupancy InspectionPassView ↗
10/11/2022No Access-Final CND-Occupancy InspectionNo AccessView ↗
07/29/2022Certified Remove/Cap - work done in accordance with codeCertifiedView ↗
07/29/2022Certified Water and Sanitary-WS-Fixtures-FinishCertifiedView ↗
12/30/2021Certified Water and Sanitary-WS-Sanitary Piping-RoughingCertifiedView ↗
▾Special Inspection Requirements (DOB NOW) — 33
DateRequirementInspectorRole
07/11/2022Fire-Resistant Penetrations and JointsDavid Millerspecial
07/11/2022Energy Code Compliance InspectionsDavid Millerprogress
07/11/2022HVAC-R and service water piping design and insulationDavid Millerenergy_progress
07/06/2022HVAC-R and service water piping design and insulationDavid Millerenergy_progress
07/06/2022Energy Code Compliance InspectionsDavid Millerprogress
07/06/2022Fire-Resistant Penetrations and JointsDavid Millerspecial
07/05/2022Interior lighting powerDavid Millerenergy_progress
07/05/2022Air barrier - visual inspectionDavid Millerenergy_progress
07/05/2022MeteringDavid Millerenergy_progress
07/05/2022Fire-Resistant Penetrations and JointsDavid Millerspecial
07/05/2022Mechanical SystemsDavid Millerspecial
07/05/2022Energy Code Compliance InspectionsDavid Millerprogress
07/05/2022FinalDavid Millerprogress
07/05/2022Fenestration and door U-factor and product ratingsDavid Millerenergy_progress
07/05/2022Permanent certificateDavid Millerenergy_progress
07/21/2021Structural Steel - High Strength BoltingCelin Munozspecial
07/21/2021Structural Steel - WeldingCelin Munozspecial
07/21/2021Subgrade InspectionsCelin Munozspecial
07/21/2021Subsurface Conditions – Fill Placement & In-Place DensityCelin Munozspecial
07/21/2021Post-installed AnchorsCelin Munozspecial
07/21/2021FinalCelin Munozprogress
07/21/2021Structural Steel - DetailsCelin Munozspecial
07/21/2021Concrete - Cast-In-PlaceCelin Munozspecial
07/21/2021Structural Stability – Alterations of existing buildingsCelin Munozspecial
07/20/2021Fire-Resistant Penetrations and JointsDavid Millerspecial
Latest 25 of 33.
▾Documents — 88 on file (BIS + DOB NOW)
▸Plans & Drawings6
▸DOB NOWPlans/Sketch6
09/01/2026B00534683-P3Request digital key ↗
09/01/2026B00534683-S1Request digital key ↗
09/01/2026B00534683-I1Request digital key ↗
Showing 3 of 6 on file for this type
▸Applications & Permits6
▸BISPLAN / WORK APPROVAL APPLICATION3
07/09/2021340816727Open ↗
12/14/2015321101678Open ↗
04/14/2015321101678Open ↗
▸BISWORK PERMIT APPLICATION3
07/14/2021340816727Open ↗
10/19/2015321101678Open ↗
06/05/2015321101678Open ↗
▸Seals & Professional Certifications34
▸DOB NOWSpecial Inspector Seal & Signature14
08/30/2026B00534683-P3Open ↗
08/27/2026B00534683-S1Open ↗
08/27/2026B00534683-P1Open ↗
Showing 3 of 14 on file for this type
▸DOB NOWProgress Inspector Seal & Signature9
08/30/2026B00534683-P3Open ↗
08/30/2026B00534683-P3Open ↗
08/27/2026B00534683-S1Open ↗
Showing 3 of 9 on file for this type
▸DOB NOWDPL-1: Design Professional Seal & Signature6
08/13/2026B00534683-S1Open ↗
08/13/2026B00534683-I1Open ↗
08/13/2026B00534683-P1Open ↗
Showing 3 of 6 on file for this type
▸BISTECHNICAL REPORT: RESPONSIBILITY/CERTIFICATION4
06/12/2017321101678Open ↗
06/08/2017321101678Open ↗
06/05/2015321101678Open ↗
Showing 3 of 4 on file for this type
▸BISAPPLICANT OWNER SIGNATURE1
07/09/2021340816727Open ↗
▸Trade Schedules & Equipment2
▸BISSCHEDULE B - PLUMBING/SPRINKLER/STANDPIPE2
12/14/2015321101678Open ↗
04/14/2015321101678Open ↗
▸Safety & Tenant Protection5
▸DOB NOWStreet Tree Checklist3
08/13/2026B00534683-I1Open ↗
08/13/2026B00534683-P1Open ↗
08/13/2026B00534683-P2Open ↗
▸BISTPP1: TENANT PROTECTION PLAN1
07/14/2021340816727Open ↗
▸DOB NOWParks Department Acknowledgment Letter for Street Trees Plan1
08/13/2026B00534683-I1Open ↗
▸Environmental & Asbestos8
▸DOB NOWDEP ACP-5: Asbestos Assessment Report6
08/13/2026B00534683-P1Open ↗
08/13/2026B00534683-P2Open ↗
08/13/2026B00534683-P3Open ↗
Showing 3 of 6 on file for this type
▸BISASBESTOS: CERTIFICATION (DEP ACP5)2
07/09/2021340816727Open ↗
04/09/2015321101678Open ↗
▸Energy Compliance11
▸BISTECHNICAL REPORT: ENERGY CODE PROGRESS INSPS4
06/08/2017321101678Open ↗
06/06/2017321101678Open ↗
06/05/2015321101678Open ↗
Showing 3 of 4 on file for this type
▸BISAS-BUILT ENERGY ANALYSIS2
10/25/2021340816727Open ↗
06/12/2017321101678Open ↗
▸BISTECHNICAL REPORT: ENERGY CODE - RESPONSIBILITY2
10/25/2021340816727Open ↗
07/09/2021340816727Open ↗
▸BISSOLAR TAX ABATEMENT APPLICATION1
10/25/2021340816727Open ↗
▸BISPTA4: SOLAR TAX ABATEMENT APPLICATION (PRELIMINARY)1
07/09/2021340816727Open ↗
▸DOB NOWEN2: As Built Energy Analysis.1
08/13/2026B00534683-I1Open ↗
▸Inspections & Test Reports2
▸BISTECHNICAL REPORT: RESPONSIBILITY2
10/25/2021340816727Open ↗
07/09/2021340816727Open ↗
▸Approvals, Objections & Sign-offs7
▸BISCERTIFICATE OF OCCUPANCY/LOC: REQUEST5
10/25/2021340816727Open ↗
06/16/2017321101678Open ↗
06/14/2017321101678Open ↗
Showing 3 of 5 on file for this type
▸BISLETTERS - SUPPORTING DOCUMENTATION1
10/25/2021340816727Open ↗
▸BISADMINISTRATIVE OBJECTIONS1
04/14/2015321101678Open ↗
▸Cost, Insurance & Ownership4
▸BISCOST AFFIDAVIT4
10/25/2021340816727Open ↗
07/09/2021340816727Open ↗
06/12/2017321101678Open ↗
Showing 3 of 4 on file for this type
▸Filing & Intake Forms2
▸BISEFILING COVER SHEET1
04/09/2015321101678Open ↗
▸BISEFILING JOB APPLICATION COVER SHEET1
07/09/2021340816727Open ↗
▸Other Documents1
▸BISCONSTRUCTION - SUPPORTING DOCUMENTATION1
07/15/2016321101678Open ↗