← Back
Two stories - detached, small or mid-size
6135 TYNDALL AVENUE
BRONX · Riverdale-Spuyten Duyvil · BIN 2085594
💬 Discuss this project
1920Year Built
2Stories
A1Building Class
R3AZoning
2,232 sfGross Floor Area
1Units
Two stories - detached, small or mid-size · 4,750 sf lot · 0.47 FAR built · Flood zone X
Locations of Work
ArchitectureElectrical
Roof1p · 1 filing · 9 docs
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
TOM PETERSEN ARCHITECT, LLC109/11/2025
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
VOLTAIC SOLAIRE LLCGeneral Contractor104/08/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
THOMAS PETERSEN ARCHITECT7854109/11/2025
Building Lifecycle
All (8)Filed (1)Permit Issued (1)Signed Off (1)Special Inspection (5)
01/14/2026
Signed off — Alteration
Installation of PV system on existing roof no change to egress or use of occupancy
X01285048-I1
09/18/2025
Permit issued — Solar
X01285048-I1-SL
09/11/2025
Filed — Alteration
Installation of PV system on existing roof no change to egress or use of occupancy
X01285048-I1
09/10/2025
Special inspection requirement — Fire-Resistant Penetrations and Joints
TOM PETERSEN
09/10/2025
Special inspection requirement — Structural Stability – Alterations of existing buildings
TOM PETERSEN
09/10/2025
Special inspection requirement — Energy Code Compliance Inspections
TOM PETERSEN
09/10/2025
Special inspection requirement — Final
TOM PETERSEN
09/10/2025
Special inspection requirement — Air barrier - visual inspection
TOM PETERSEN
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWSolarSigned-offVOLTAIC SOLAIRE LLC09/18/2025
1 project · most recent 09/08/2025
FiledStatusContractorScope
09/08/2025CompleteBERGER QUALITY ELEC'L CON—
▾Special Inspection Requirements (DOB NOW) — 5
DateRequirementInspectorRole
09/10/2025Fire-Resistant Penetrations and JointsTOM PETERSENspecial
09/10/2025Structural Stability – Alterations of existing buildingsTOM PETERSENspecial
09/10/2025Energy Code Compliance InspectionsTOM PETERSENprogress
09/10/2025FinalTOM PETERSENprogress
09/10/2025Air barrier - visual inspectionTOM PETERSENenergy_progress
▾Documents — 9 on file (BIS + DOB NOW)
▸Plans & Drawings1
▸DOB NOWPlans/Sketch1
08/18/2026X01285048-I1Request digital key ↗
▸Seals & Professional Certifications6
▸DOB NOWProgress Inspector Seal & Signature3
08/23/2026X01285048-I1Open ↗
08/23/2026X01285048-I1Open ↗
08/23/2026X01285048-I1Open ↗
▸DOB NOWSpecial Inspector Seal & Signature2
08/23/2026X01285048-I1Open ↗
08/23/2026X01285048-I1Open ↗
▸DOB NOWDPL-1: Design Professional Seal & Signature1
08/18/2026X01285048-I1Open ↗
▸Environmental & Asbestos1
▸DOB NOWDEP ACP-5: Asbestos Assessment Report1
08/18/2026X01285048-I1Open ↗
▸Approvals, Objections & Sign-offs1
▸DOB NOWUtility Company Final Acceptance Letter1
08/13/2026X01285048-I1Open ↗