← Back
Three families
617 CARLTON AVENUE
BROOKLYN · Prospect Heights · BIN 3028386
💬 Discuss this project
1868Year Built
3Stories
C0Building Class
R6BZoning
3,948 sfGross Floor Area
3Units
Rent Stabilized3 Open Violations ▸FDNY Report ↗
Three families · 2,100 sf lot · 1.88 FAR built · Flood zone X
Locations of Work
Plumbing
Floor 42p · 1 filing · 20 docs
Floor 32p · 1 filing · 20 docs
Floor 24p · 1 filing · 20 docs
Floor 12p · 1 filing · 20 docs
Cellar2p · 1 filing · 20 docs
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
MABBOTT SEIDEL ARCHITECTURE, PLLC402/05/2020
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
MABBOTT SEIDEL ARCHITECTURE803/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
ORBIT PLBG & HTG INCPlumbing807/08/2026
ORBIT PLUMBING HEATINGGeneral Contractor103/22/2026
Building Lifecycle
All (15)Filed (4)Permit Issued (1)Signed Off (1)Violation (9)
05/04/2026
Violation issued (HPD, closed)
A
06/09/2025
Violation issued (HPD, closed)
A
04/27/2023
Violation issued (DOB, open)
V-DOB VIOLATION - ACTIVE
03/21/2023
Violation issued (HPD, closed)
A
08/05/2021
Signed off — Alteration
REPLACE (1) KITCHEN SINK, (1) DW, (2) LAVATORY, (2) WC, (1) BATHTUB. INSTALL (1) NEW SHOWER. REPLACE GAS PIPING.
B00227485-I1
02/05/2020
Filed — Alteration
REPLACE (1) KITCHEN SINK, (1) DW, (2) LAVATORY, (2) WC, (1) BATHTUB. INSTALL (1) NEW SHOWER. REPLACE GAS PIPING.
B00227485-P3
10/31/2019
Filed — Alteration
REPLACE (1) KITCHEN SINK, (1) DW, (2) LAVATORY, (2) WC, (1) BATHTUB. INSTALL (1) NEW SHOWER. REPLACE GAS PIPING.
B00227485-P2
10/23/2019
Filed — Alteration
REPLACE (1) KITCHEN SINK, (1) DW, (2) LAVATORY, (2) WC, (1) BATHTUB. INSTALL (1) NEW SHOWER. REPLACE GAS PIPING.
B00227485-P1
09/23/2019
Permit issued — Plumbing
B00227485-I1-PL
09/20/2019
Filed — Alteration
REPLACE (1) KITCHEN SINK, (1) DW, (2) LAVATORY, (2) WC, (1) BATHTUB. INSTALL (1) NEW SHOWER. REPLACE GAS PIPING.
B00227485-I1
11/20/2017
Violation issued (HPD, closed)
I
10/07/2015
Violation issued (HPD, closed)
I
02/18/2015
Violation issued (HPD, closed)
I
06/04/1998
Violation issued (HPD, open)
B
10/23/1985
Violation issued (HPD, open)
B
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWPlumbingSigned-offORBIT PLBG & HTG INC09/23/2019
BISOTISSUEDMABBBOTT SEIDEL BUILD LLC08/05/2019
Nothing on file for this building.
Nothing on file for this building.
▾Documents — 47 on file (BIS + DOB NOW)
▸Plans & Drawings4
▸DOB NOWPlans/Sketch - Plumbing4
09/02/2026B00227485-I1Request digital key ↗
08/15/2026B00227485-P3Request digital key ↗
08/15/2026B00227485-P1Request digital key ↗
Showing 3 of 4 on file for this type
▸Applications & Permits6
▸DOB NOWLPC Approval/Permit4
08/13/2026B00227485-I1Open ↗
08/13/2026B00227485-P3Open ↗
08/13/2026B00227485-P1Open ↗
Showing 3 of 4 on file for this type
▸BISPLAN / WORK APPROVAL APPLICATION1
08/02/2019340688660Open ↗
▸BISWORK PERMIT APPLICATION1
08/02/2019340688660Open ↗
▸Seals & Professional Certifications7
▸DOB NOWDPL-1: Design Professional Seal & Signature4
08/13/2026B00227485-I1Open ↗
08/13/2026B00227485-P1Open ↗
08/13/2026B00227485-P2Open ↗
Showing 3 of 4 on file for this type
▸BISREQUIRED ITEMS CHECKLIST FOR PROFESSIONAL CERTIFICATION1
08/02/2019340688660Open ↗
▸BISPROFESSIONAL CERTIFICATION STATEMENT1
08/02/2019340688660Open ↗
▸BISTECHNICAL REPORT STATEMENT OF RESPONSIBILITY1
08/02/2019340688660Open ↗
▸Safety & Tenant Protection5
▸DOB NOWTenant Protection Plan4
08/13/2026B00227485-I1Open ↗
08/13/2026B00227485-P3Open ↗
08/13/2026B00227485-P1Open ↗
Showing 3 of 4 on file for this type
▸BISTENANT PROTECTION PLAN AND NOTES1
08/02/2019340688660Open ↗
▸Environmental & Asbestos5
▸DOB NOWDEP ACP-5: Asbestos Assessment Report4
08/13/2026B00227485-P1Open ↗
08/13/2026B00227485-P2Open ↗
08/13/2026B00227485-I1Open ↗
Showing 3 of 4 on file for this type
▸BISASBESTOS: CERTIFICATION (DEP ACP5)1
08/02/2019340688660Open ↗
▸Energy Compliance9
▸BISTECHNICAL REPORT: ENERGY CODE - RESPONSIBILITY3
05/12/2020340688660Open ↗
05/12/2020340688660Open ↗
08/02/2019340688660Open ↗
▸BISTECHNICAL REPORT STATEMENT OF RESPONSIBILITY FOR ENERGY CODE PROGRESS INSPECTIONS1
08/02/2019340688660Open ↗
▸BISINTERIOR LIGHTING POWER1
08/02/2019340688660Open ↗
▸BISAS-BUILT ENERGY ANALYSIS1
05/12/2020340688660Open ↗
▸BISNYCECC ANALYSIS1
08/02/2019340688660Open ↗
▸BISENERGY CODE COMPLIANCE INSPECTIONS1
08/02/2019340688660Open ↗
▸BISLIGHTING CONTROLS1
08/02/2019340688660Open ↗
▸Inspections & Test Reports5
▸BISTECHNICAL REPORT: RESPONSIBILITY3
05/12/2020340688660Open ↗
05/12/2020340688660Open ↗
08/02/2019340688660Open ↗
▸BISFIRE-RESISTANT PENETRATIONS AND JOINTS (FIRESTOP)1
08/02/2019340688660Open ↗
▸BISDIR-14 ID OF RESPONSIBILITY (TR1)1
08/02/2019340688660Open ↗
▸Approvals, Objections & Sign-offs3
▸BISCERTIFICATE OF OCCUPANCY/LOC: REQUEST1
05/12/2020340688660Open ↗
▸BISFINAL1
08/02/2019340688660Open ↗
▸BISLANDMARKS APPROVAL1
08/02/2019340688660Open ↗
▸Cost, Insurance & Ownership2
▸BISCOST AFFIDAVIT2
05/12/2020340688660Open ↗
08/02/2019340688660Open ↗
▸Filing & Intake Forms1
▸BISEFILING JOB APPLICATION COVER SHEET1
08/02/2019340688660Open ↗