← Back
Two family frame
62-04 HILLMEYER ROAD
QUEENS · BIN 4617835
💬 Discuss this project
2024Year Built
2Stories
B2Building Class
R4-1Zoning
2,281 sfGross Floor Area
2Units
Two family frame · 8,414 sf lot · 0.27 FAR built · Flood zone AE
Locations of Work
StructuralFire ProtectionGeneral
Roof1p · 1 filing · 20 docs
Floor 23p · 2 filings · 20 docs
Floor 12p · 2 filings · 20 docs
1 job · most recent 06/23/2022
Air Conditioning Systems Heating Systems Ventilation Systems
FiledStatusContractorScopeMake / Model / Capacity
06/23/2022Permit IssuedCHAIT BUILDERS INCAir Conditioning Systems, Heating Systems, Ventilation Systems
Cooling
Emerson Quiet Kool 12,000 BTU ×8
Heating
Navien NAVIEN NCB-E 240e 94,000 BTU · Boiler ×1
Ventilation
Whisperline FV-0510VS1 50 CFM · Exhaust Fan ×2
FV-10NLF1 100 CFM · Kitchen Exhaust ×2
2 jobs · most recent 09/02/2025
General Wiring
FiledStatusContractorScope
09/02/2025CancelledPURCELL ELEC'L CONTRS LTDGeneral Wiring
07/01/2024CompletePURCELL ELEC'L CONTRS LTDGeneral Wiring
1 job · most recent 06/23/2022
Concrete Wood
FiledStatusContractorScope
06/23/2022Permit IssuedCHAIT BUILDERS INCConcrete, Wood
Building Lifecycle
All (67)Filed (6)Permit Issued (5)Signed Off (3)Inspection (11)Objection (12)Special Inspection (30)
07/23/2025
Inspection — Pass-Final CND-Occupancy Inspection
Pass
View inspection ↗
07/17/2025
Inspection — Pass-Final CND-Occupancy Inspection
Pass
View inspection ↗
06/13/2025
Signed off — Alteration
Installation of plumbing fixtures and sprinklers for new 2-family dwelling
Q00693120-I1
05/22/2025
Filed — Alteration
Installation of plumbing fixtures and sprinklers for new 2-family dwelling
Q00693120-P3
05/21/2025
Special inspection requirement — Soil Percolation Test - Private On-Site Storm Water Drainage Disposal Systems, and Detention Facilities
PAUL MARINO
05/21/2025
Special inspection requirement — Fire-Resistant Penetrations and Joints
PAUL MARINO
05/21/2025
Special inspection requirement — Subsurface Investigations (Borings/Test Pits)
SAMER ABOU-GHAIDA
05/21/2025
Special inspection requirement — Sprinkler Systems
PAUL MARINO
05/21/2025
Special inspection requirement — Energy Code Compliance Inspections
PAUL MARINO
04/30/2025
Inspection — Fail-Final CND-Occupancy Inspection
Fail
View inspection ↗
04/24/2025
Signed off — Alteration
PROPOSED NEW 10' CURB CUT FOR NEW 2 FAMILY DWELLING.
Q00687722-I1
04/16/2025
Inspection — No Access-Final CND-Occupancy Inspection
No Access
View inspection ↗
02/25/2025
Inspection — Pass-Final CND-Occupancy Inspection
Pass
View inspection ↗
02/13/2025
Inspection — Pass-Final Curb Cut Non-Directive 14
Pass
View inspection ↗
10/29/2024
Inspection — Fail-Final Curb Cut Non-Directive 14
Fail
View inspection ↗
10/23/2024
Inspection — Pass-Final PL - Up to 3 Requested Floors
Pass
View inspection ↗
10/21/2024
Signed off — Alteration
8' PLYWOOD CONSTRUCTION FENCE INSIDE THE PROPERTY LINE.
Q00688483-I1
10/13/2024
Inspection — Certified Sprinkler (PL)-Sprinkler-Hydro
Certified
View inspection ↗
09/18/2024
Permit issued — Foundation
Q00692004-I1-GC-CX
09/03/2024
Inspection — Pass-Final PL - Up to 3 Requested Floors
Pass
View inspection ↗
08/09/2024
Inspection — Pass-Final PL - Up to 3 Requested Floors
Pass
View inspection ↗
07/08/2024
Permit issued — Plumbing
Q00693120-I1-PL
03/19/2024
Permit issued — Foundation
Q00692004-I1-GC-CX
03/05/2024
Permit issued — Construction Fence
Q00688483-I1-FN
03/05/2024
Permit issued — Curb Cut
Q00687722-I1-CC
04/03/2023
Filed — Alteration
Installation of plumbing fixtures and sprinklers for new 2-family dwelling
Q00693120-P1
08/08/2022
Special inspection requirement — Sprinkler Systems
08/08/2022
Special inspection requirement — Subsurface Investigations (Borings/Test Pits)
PAUL MARINO
08/08/2022
Special inspection requirement — Energy Code Compliance Inspections
PAUL MARINO
08/08/2022
Special inspection requirement — Electric vehicle service equipment requirements
PAUL MARINO
08/08/2022
Special inspection requirement — Fire-Resistant Penetrations and Joints
PAUL MARINO
08/08/2022
Special inspection requirement — On-Site Private Sewage Disposal Systems Installation
PAUL MARINO
08/08/2022
Special inspection requirement — Soil Percolation Test - Private On-Site Storm Water Drainage Disposal Systems, and Detention Facilities
PAUL MARINO
06/28/2022
Objection raised — Inspections
06/28/2022
Objection resolved — Addressed
06/28/2022
Objection raised — Zoning
06/28/2022
Objection resolved — Addressed
06/28/2022
Objection raised — Scope
06/28/2022
Objection resolved — Addressed
06/28/2022
Objection raised — Admin
06/28/2022
Objection resolved — Addressed
06/28/2022
Objection raised — Energy
06/28/2022
Objection resolved — Addressed
06/28/2022
Objection raised — Fire_Protection
06/28/2022
Objection resolved — Addressed
06/24/2022
Filed — Alteration
Installation of plumbing fixtures and sprinklers for new 2-family dwelling
Q00693120-I1
06/23/2022
Filed — New Building
PROPOSED NEW 2-FAMILY DWELLING.
Q00692004-I1
06/23/2022
Special inspection requirement — Wood – Prefabricated I-Joists
PAUL MARINO
06/16/2022
Filed — Alteration
PROPOSED NEW 10' CURB CUT FOR NEW 2 FAMILY DWELLING.
Q00687722-I1
06/16/2022
Filed — Alteration
8' PLYWOOD CONSTRUCTION FENCE INSIDE THE PROPERTY LINE.
Q00688483-I1
03/04/2022
Special inspection requirement — Fire-Resistance Rated Construction
PAUL MARINO
03/04/2022
Special inspection requirement — Lowest Floor Elevation
PAUL MARINO
03/04/2022
Special inspection requirement — Structural Wood Frame
PAUL MARINO
03/04/2022
Special inspection requirement — Metering
PAUL MARINO
03/04/2022
Special inspection requirement — Air barrier — testing
PAUL MARINO
03/04/2022
Special inspection requirement — Fenestration and door U-factor and product ratings
PAUL MARINO
03/04/2022
Special inspection requirement — HVAC-R and service water piping design and insulation
PAUL MARINO
03/04/2022
Special inspection requirement — Permanent certificate
PAUL MARINO
03/04/2022
Special inspection requirement — Ventilation and air distribution system
PAUL MARINO
03/04/2022
Special inspection requirement — Insulation placement and R values
PAUL MARINO
Latest 60 of 67 events.
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
CHAIT BUILDERS2007/08/2026
▾Sales History (ACRIS)
DatePriceUnitSeller → Buyer$/sf
08/14/2025$995K—DSC PROPERTIES, INC. → Private party$436/sf building
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
T.F. CUSANELLI & FILLETTI ARCH605/22/2025
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
CHAIT BUILDERS INCGeneral Contractor607/08/2026
D & G PLUMBING CO. INCPlumbing107/08/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
ENGINEERING CONSULTING SE2050405/22/2025
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWFoundationPermit IssuedCHAIT BUILDERS INC09/18/2024
DOB NOWPlumbingSigned-offD & G PLUMBING CO. INC07/08/2024
DOB NOWFoundationPermit IssuedCHAIT BUILDERS INC03/19/2024
DOB NOWConstruction FenceSigned-offCHAIT BUILDERS INC03/05/2024
DOB NOWCurb CutSigned-offCHAIT BUILDERS INC03/05/2024
▾Field Inspections (DOB CAP) — 11
DateTypeResultReport
07/23/2025Pass-Final CND-Occupancy InspectionPassView ↗
07/17/2025Pass-Final CND-Occupancy InspectionPassView ↗
04/30/2025Fail-Final CND-Occupancy InspectionFailView ↗
04/16/2025No Access-Final CND-Occupancy InspectionNo AccessView ↗
02/25/2025Pass-Final CND-Occupancy InspectionPassView ↗
02/13/2025Pass-Final Curb Cut Non-Directive 14PassView ↗
10/29/2024Fail-Final Curb Cut Non-Directive 14FailView ↗
10/23/2024Pass-Final PL - Up to 3 Requested FloorsPassView ↗
10/13/2024Certified Sprinkler (PL)-Sprinkler-HydroCertifiedView ↗
09/03/2024Pass-Final PL - Up to 3 Requested FloorsPassView ↗
08/09/2024Pass-Final PL - Up to 3 Requested FloorsPassView ↗
▾Special Inspection Requirements (DOB NOW) — 43
DateRequirementInspectorRole
05/21/2025Soil Percolation Test - Private On-Site Storm Water Drainage Disposal Systems, and Detention FacilitiesPAUL MARINOspecial
05/21/2025Fire-Resistant Penetrations and JointsPAUL MARINOspecial
05/21/2025Subsurface Investigations (Borings/Test Pits)SAMER ABOU-GHAIDAspecial
05/21/2025Sprinkler SystemsPAUL MARINOspecial
05/21/2025Energy Code Compliance InspectionsPAUL MARINOprogress
08/08/2022Sprinkler Systems—special
08/08/2022Subsurface Investigations (Borings/Test Pits)PAUL MARINOspecial
08/08/2022Energy Code Compliance InspectionsPAUL MARINOprogress
08/08/2022Electric vehicle service equipment requirementsPAUL MARINOenergy_progress
08/08/2022Fire-Resistant Penetrations and JointsPAUL MARINOspecial
08/08/2022On-Site Private Sewage Disposal Systems InstallationPAUL MARINOspecial
08/08/2022Soil Percolation Test - Private On-Site Storm Water Drainage Disposal Systems, and Detention FacilitiesPAUL MARINOspecial
06/23/2022Wood – Prefabricated I-JoistsPAUL MARINOspecial
03/04/2022Fire-Resistance Rated ConstructionPAUL MARINOprogress
03/04/2022Lowest Floor ElevationPAUL MARINOprogress
03/04/2022Structural Wood FramePAUL MARINOprogress
03/04/2022MeteringPAUL MARINOenergy_progress
03/04/2022Air barrier — testing PAUL MARINOenergy_progress
03/04/2022Fenestration and door U-factor and product ratingsPAUL MARINOenergy_progress
03/04/2022HVAC-R and service water piping design and insulationPAUL MARINOenergy_progress
03/04/2022Permanent certificatePAUL MARINOenergy_progress
03/04/2022Ventilation and air distribution systemPAUL MARINOenergy_progress
03/04/2022Insulation placement and R valuesPAUL MARINOenergy_progress
03/04/2022Fenestration areasPAUL MARINOenergy_progress
03/04/2022Duct leakage testing, insulation and designPAUL MARINOenergy_progress
Latest 25 of 43.
▾Documents — 71 on file (BIS + DOB NOW)
▸Plans & Drawings6
▸DOB NOWPlans/Sketch6
08/26/2026Q00688483-I1Request digital key ↗
08/26/2026Q00687722-I1Request digital key ↗
08/26/2026Q00693120-P1Request digital key ↗
Showing 3 of 6 on file for this type
▸Zoning, Tax Lot & Property Records3
▸DOB NOWRestrictive Declaration/Easement 11
08/13/2026Q00692004-I1Open ↗
▸DOB NOWHouse Number Verification: TOPO Stamp1
08/13/2026Q00692004-I1Open ↗
▸DOB NOWZD1: DOB Zoning Diagram1
08/13/2026Q00692004-I1Open ↗
▸Seals & Professional Certifications47
▸DOB NOWProgress Inspector Seal & Signature24
09/01/2026Q00693120-P1Open ↗
08/25/2026Q00693120-P3Open ↗
08/25/2026Q00692004-I1Open ↗
Showing 3 of 24 on file for this type
▸DOB NOWSpecial Inspector Seal & Signature17
09/01/2026Q00693120-P1Open ↗
09/01/2026Q00693120-P1Open ↗
09/01/2026Q00693120-P1Open ↗
Showing 3 of 17 on file for this type
▸DOB NOWDPL-1: Design Professional Seal & Signature6
08/26/2026Q00692004-I1Open ↗
08/26/2026Q00693120-I1Open ↗
08/26/2026Q00693120-P1Open ↗
Showing 3 of 6 on file for this type
▸Trade Schedules & Equipment1
▸DOB NOWDEP: Sewer Certification (Sanitary/Storm)1
08/13/2026Q00692004-I1Open ↗
▸Safety & Tenant Protection3
▸DOB NOWParks Department Acknowledgment Letter for Street Trees Plan1
08/13/2026Q00692004-I1Open ↗
▸DOB NOWStreet Tree Checklist1
08/13/2026Q00692004-I1Open ↗
▸DOB NOWStreet Trees Site Plan1
08/13/2026Q00692004-I1Open ↗
▸Inspections & Test Reports7
▸DOB NOWSOIL REPORT4
08/13/2026Q00692004-I1Open ↗
08/13/2026Q00693120-P3Open ↗
08/13/2026Q00693120-P1Open ↗
Showing 3 of 4 on file for this type
▸DOB NOWTR4 Test Report and Plot Diagram2
08/13/2026Q00692004-I1Open ↗
08/13/2026Q00693120-I1Open ↗
▸DOB NOWTR5 Test Report1
08/13/2026Q00692004-I1Open ↗
▸Other Documents4
▸DOB NOWProperty Ownership Certification1
08/14/2026Q00692004-I1Open ↗
▸DOB NOWFEMA Elevation Certificate (086-0-33)/Flood Proofing Certificate (086-0-34)1
08/13/2026Q00692004-I1Open ↗
▸DOB NOWFinal Survey1
08/13/2026Q00692004-I1Open ↗
▸DOB NOWLocal Law 92/94 of 2019 Sustainable Roof Zone1
08/13/2026Q00692004-I1Open ↗