← Back
Two family converted from one family
62-30 60 DRIVE
QUEENS · BIN 4061736
💬 Discuss this project
1925Year Built
2Stories
B3Building Class
R4-1Zoning
1,344 sfGross Floor Area
2Units
Two family converted from one family · 2,000 sf lot · 0.67 FAR built · Flood zone X
Locations of Work
Architecture
Floor 21p · 1 filing · 3 docs
Floor 1
▾Sales History (ACRIS)
DatePriceUnitSeller → Buyer$/sf
02/19/2025$738K—Private party → Private party$549/sf building
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
NMI ARCHITECTURE, PLLC204/14/2025
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
SKY LINE BUILDERS USA INCGeneral Contractor103/21/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
JUN YAN, PE7170103/24/2025
NMI ARCHITECTURE, PLLC6825103/24/2025
Building Lifecycle
All (12)Filed (2)Permit Issued (1)Signed Off (1)Inspection (1)Objection (6)Special Inspection (1)
10/24/2025
Signed off — Alteration
THIS APPLICATION IS FILED FOR NEW LAYOUT TO 1ST FLOOR, MINOR CHANGES TO THE CELLAR ,& 2ND FLOOR, ALL PLUMBING TO BE FILED UNDER SEPARATE APPLICATION, NO CHANGE OF USE, EGRESS OR OCCUPANCY.
Q01187178-I1
09/19/2025
Inspection — Pass-Final General Construction Non-Directive 14
Pass
View inspection ↗
06/02/2025
Permit issued — General Construction
Q01187178-I1-GC
04/14/2025
Filed — Alteration
THIS APPLICATION IS FILED FOR ALL THE PLUMBING WORK IN CONJ WITH ALT-2 APPLICATION # Q01187178, NEW KITCHEN& FULL BATHROOM AT 1ST FL. , & NEW LAUNDRY ROOM AT 2ND FLOOR, NO CHANGE OF USE, EGRESS OR OCCUPANCY
Q01187190-I1
04/03/2025
Objection resolved — Addressed
04/03/2025
Objection resolved — Addressed
04/03/2025
Objection resolved — Addressed
03/28/2025
Objection raised — Mechanical
03/28/2025
Objection raised — Cost
03/28/2025
Objection raised — Scope
03/24/2025
Filed — Alteration
THIS APPLICATION IS FILED FOR NEW LAYOUT TO 1ST FLOOR, MINOR CHANGES TO THE CELLAR ,& 2ND FLOOR, ALL PLUMBING TO BE FILED UNDER SEPARATE APPLICATION, NO CHANGE OF USE, EGRESS OR OCCUPANCY.
Q01187178-I1
02/26/2025
Special inspection requirement — Fire-Resistant Penetrations and Joints
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWGeneral ConstructionSigned-offSKY LINE BUILDERS USA INC06/02/2025
1 project · most recent 04/14/2025
Water/Sanitary
FiledStatusContractorScope
04/14/2025——Water/Sanitary
▾Field Inspections (DOB CAP) — 1
DateTypeResultReport
09/19/2025Pass-Final General Construction Non-Directive 14PassView ↗
▾Special Inspection Requirements (DOB NOW) — 1
DateRequirementInspectorRole
02/26/2025Fire-Resistant Penetrations and Joints—special
▾Documents — 6 on file (BIS + DOB NOW)
▸Plans & Drawings2
▸DOB NOWPlans/Sketch2
08/20/2026Q01187178-I1Request digital key ↗
08/20/2026Q01187190-I1Request digital key ↗
▸Seals & Professional Certifications2
▸DOB NOWDPL-1: Design Professional Seal & Signature2
08/20/2026Q01187178-I1Open ↗
08/13/2026Q01187190-I1Open ↗
▸Environmental & Asbestos2
▸DOB NOWDEP ACP-5: Asbestos Assessment Report2
08/20/2026Q01187178-I1Open ↗
08/13/2026Q01187190-I1Open ↗