| Owner | Filings | Most Recent |
|---|---|---|
| EMPIRE BUILDERS GROUP NY | 1 | 03/22/2026 |
| Date | Price | Unit | Seller → Buyer | $/sf |
|---|---|---|---|---|
| 05/10/2023 | $1.3M | — | Private party → Private party | $406/sf building |
| Firm | Filings | Most Recent |
|---|---|---|
| EAST + WEST ARCHITECTURE PC | 12 | 08/03/2026 |
| M-CON ENGINEERING, PC | 1 | 12/20/2024 |
| Representative | Filings | Most Recent |
|---|---|---|
| XUX CONSULTING | 20 | 03/21/2026 |
| Firm | Trade | Roles | Most Recent |
|---|---|---|---|
| EMPIRE BUILDERS GROUP NY | General Contractor | 7 | 04/09/2026 |
| SUSTAINABLE STRATEGIES | General Contractor | 2 | 03/21/2026 |
| DPH PLUMBING & HTG CORP | Plumbing | 1 | 07/08/2026 |
| KISHAN PLUMBING INC | Plumbing | 1 | 07/08/2026 |
| Agency | License # | Filings | Most Recent |
|---|---|---|---|
| FLUSHING ENGINEERING SERV | 4373 | 4 | 08/03/2026 |
| SJS INSPECTIONS AND CONSU | 8286 | 5 | 08/03/2026 |
| EAST+WEST ARCHITECTURE, P | 3269 | 6 | 12/18/2025 |
| M-CON ENGINEERING | 7341 | 1 | 12/20/2024 |
| Source | Work Type | Status | Applicant | Issued |
|---|---|---|---|---|
| DOB NOW | Earth Work | Permit Issued | EMPIRE BUILDERS GROUP NY | 01/06/2026 |
| DOB NOW | Plumbing | Signed-off | DPH PLUMBING & HTG CORP | 03/14/2025 |
| DOB NOW | Structural | Permit Issued | EMPIRE BUILDERS GROUP NY | 12/27/2024 |
| DOB NOW | Construction Fence | Signed-off | EMPIRE BUILDERS GROUP NY | 12/27/2024 |
| DOB NOW | Solar | Signed-off | SUSTAINABLE STRATEGIES | 12/26/2024 |
| DOB NOW | Plumbing | Signed-off | N AND S PLUMBING INC | 03/06/2024 |
| DOB NOW | Mechanical Systems | Permit Issued | EMPIRE BUILDERS GROUP NY | 01/03/2024 |
| DOB NOW | Construction Fence | Signed-off | EMPIRE BUILDERS GROUP NY | 12/29/2023 |
| DOB NOW | Curb Cut | Signed-off | EMPIRE BUILDERS GROUP NY | 12/29/2023 |
| Filed | Status | Contractor | Scope | Make / Model / Capacity |
|---|---|---|---|---|
| 08/03/2026 | Permit Issued | EMPIRE BUILDERS GROUP NY | Heating and Air Conditioning Systems, Ventilation Systems | Heat / Cool Mitsubishi Electric MXZ-4C36NA4 42,000 BTU · Vrf Outdoor ×40 MXZ-SM36NAM 42,000 BTU · Vrf Outdoor ×8 MXZ-SM48NAM 54,000 BTU · Vrf Outdoor ×8 Ventilation Trade-Wind VSL4366RC 600 CFM · Exhaust Fan ×6 Broan BHFLED110 110 CFM · Exhaust Fan ×12 |
| Filed | Status | Contractor | Scope |
|---|---|---|---|
| 08/03/2026 | Signed-off | DPH PLUMBING & HTG CORP | Gas, Water/Sanitary |
| Filed | Status | Contractor | Scope |
|---|---|---|---|
| 04/16/2026 | Complete | JOE ELECTRICAL INC | General Wiring |
| 08/01/2025 | Complete | JOE ELECTRICAL INC | General Wiring |
| 03/24/2025 | Complete | SOURCE ELECTRIC INC | 1 meters |
| Filed | Status | Contractor | Scope |
|---|---|---|---|
| 08/03/2026 | Permit Issued | EMPIRE BUILDERS GROUP NY | Concrete, Wood |
| Filed | Status | Contractor | Scope |
|---|---|---|---|
| 08/03/2026 | Permit Issued | EMPIRE BUILDERS GROUP NY | Fence |
| Date | Type | Result | Report |
|---|---|---|---|
| 03/12/2026 | Pass-Final CND-Occupancy Inspection | Pass | View ↗ |
| 03/12/2026 | Pass-Final Curb Cut Non-Directive 14 | Pass | View ↗ |
| 08/07/2025 | Pass-Final CND-Occupancy Inspection | Pass | View ↗ |
| 10/11/2024 | Certified Gas-Gas-Piping-Roughing | Certified | View ↗ |
| 10/11/2024 | Certified Storm Drainage-ST-Piping-Roughing | Certified | View ↗ |
| 09/06/2024 | Certified Storm Drainage-ST-Piping-Underground | Certified | View ↗ |
| 09/06/2024 | Certified Water and Sanitary-WS-Sanitary Piping-Underground | Certified | View ↗ |
| 08/12/2024 | Pass-Final CND-Occupancy Inspection | Pass | View ↗ |
| Date | Requirement | Inspector | Role |
|---|---|---|---|
| 07/29/2026 | Structural Wood Frame | BARBARA HESS | progress |
| 07/29/2026 | Fire-Resistant Penetrations and Joints | KY FU | special |
| 07/29/2026 | Mechanical Systems | KY FU | special |
| 07/29/2026 | Structural Stability – Alterations of existing buildings | SERGEY BOLOTOV | special |
| 07/29/2026 | Energy Code Compliance Inspections | BARBARA HESS | progress |
| 07/29/2026 | Final | BARBARA HESS | progress |
| 07/29/2026 | Fire-Resistance Rated Construction | BARBARA HESS | progress |
| 07/29/2026 | Footing and Foundation | BARBARA HESS | progress |
| 07/29/2026 | Ventilation and air distribution system | BARBARA HESS | energy_progress |
| 07/29/2026 | Permanent certificate | BARBARA HESS | energy_progress |
| 07/29/2026 | Interior lighting power | BARBARA HESS | energy_progress |
| 07/29/2026 | Duct leakage testing, insulation and design | BARBARA HESS | energy_progress |
| 07/29/2026 | Fenestration air leakage | BARBARA HESS | energy_progress |
| 07/29/2026 | Fenestration areas | BARBARA HESS | energy_progress |
| 07/29/2026 | Air barrier - visual inspection | BARBARA HESS | energy_progress |
| 07/29/2026 | Maintenance information | BARBARA HESS | energy_progress |
| 07/29/2026 | HVAC-R and service water heating equipment | BARBARA HESS | energy_progress |
| 07/29/2026 | Air barrier — testing | BARBARA HESS | energy_progress |
| 07/29/2026 | HVAC-R and service water piping design and insulation | BARBARA HESS | energy_progress |
| 07/29/2026 | Insulation placement and R values | BARBARA HESS | energy_progress |
| 07/29/2026 | Fenestration and door U-factor and product ratings | BARBARA HESS | energy_progress |
| 07/29/2026 | HVAC-R and service water heating system controls | BARBARA HESS | energy_progress |
| 05/23/2026 | Interior lighting power | BARBARA HESS | energy_progress |
| 05/23/2026 | HVAC-R and service water heating equipment | BARBARA HESS | energy_progress |
| 05/23/2026 | Fenestration and door U-factor and product ratings | BARBARA HESS | energy_progress |