← Back
Three families
62 RUSSELL STREET
BROOKLYN · BIN 3067669
💬 Discuss this project
1910Year Built
2Stories
C0Building Class
R6BZoning
2,700 sfGross Floor Area
3Units
Rent Stabilized6 Open Violations ▸FDNY Report ↗
Three families · 2,000 sf lot · 1.35 FAR built · Flood zone X
Locations of Work
ArchitectureElectricalMechanicalPlumbingFire Protection
Permit Issued — active, not yet Signed-off
RoofUnder Construction7p · 2 filings · 20 docs
Floor 3Under Construction20p · 1 filing · 20 docs
Floor 2Under Construction20p · 1 filing · 20 docs
Floor 1Under Construction21p · 1 filing · 20 docs
CellarUnder Construction21p · 1 filing · 20 docs
▾Sales History (ACRIS)
DatePriceUnitSeller → Buyer$/sf
05/04/2023$1.9M—Private party → Private party$685/sf building
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
SYNERGIC DESIGN ARCHITECTS112/04/2024
SPARK ENGINEERING103/28/2024
CX CONSULTING CORP201/16/2024
PHILIP TOSCANO ARCHITECTS301/11/2024
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
DANA TREZZA603/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
J3R BUILDERS CONTRACTINGGeneral Contractor1207/08/2026
FULTON PLBG & HTG CORPFire Protection409/12/2026
HERTLER NADILE P & H, INCPlumbing207/08/2026
ACCORD POWER INCGeneral Contractor107/08/2026
HERTLER NADILE PLMBG & HTGeneral Contractor104/09/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
SYNERGIC DESIGN LLC8561112/04/2024
SCA CODE AND PLANNING, LL6599603/28/2024
SD TESTING & INSPECTION S7010101/11/2024
Building Lifecycle
All (123)Filed (7)Permit Issued (16)Signed Off (1)Violation (10)Inspection (5)Objection (54)Special Inspection (30)
09/10/2026
Permit issued — Sprinklers
B00930112-S4-EW-SP
05/05/2026
Violation issued (HPD, open)
A
04/14/2026
Signed off — Alteration
B01129238-I1
04/03/2026
Inspection — Pass-Final CND-Occupancy Inspection
Pass
View inspection ↗
03/31/2026
Permit issued — General Construction
B00930112-I1-GC
02/06/2026
Permit issued — Mechanical Systems
B00930112-S5-MS
11/20/2025
Violation issued (HPD, open)
I
08/25/2025
Permit issued — Sprinklers
B00930112-S4-EW-SP
08/19/2025
Inspection — Certified Gas-Gas-Piping-Roughing
Certified
View inspection ↗
08/13/2025
Inspection — Certified Storm Drainage-ST-Piping-Roughing
Certified
View inspection ↗
08/13/2025
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Roughing
Certified
View inspection ↗
08/11/2025
Inspection — Certified Remove/Cap - work done in accordance with code
Certified
View inspection ↗
06/10/2025
Violation issued (HPD, open)
A
05/02/2025
Permit issued — General Construction
B00930112-I1-GC
05/02/2025
Permit issued — Foundation
B00930112-S2-FO
04/21/2025
Permit issued — Sprinklers
B00930112-S4-EW-SP
04/15/2025
Permit issued — Plumbing
B00930112-S3-PL
12/06/2024
Permit issued — Solar
B01129238-I1-SL
12/04/2024
Filed — Alteration
B01129238-I1
11/27/2024
Violation issued (HPD, open)
I
10/18/2024
Special inspection requirement — Structural Stability – Alterations of existing buildings
Malathi Ananthakrishnan
10/18/2024
Special inspection requirement — Air barrier - visual inspection
Malathi Ananthakrishnan
10/18/2024
Special inspection requirement — Energy Code Compliance Inspections
Malathi Ananthakrishnan
10/18/2024
Special inspection requirement — Fire-Resistant Penetrations and Joints
Malathi Ananthakrishnan
10/18/2024
Special inspection requirement — Final
Malathi Ananthakrishnan
09/30/2024
Permit issued — General Construction
B00930112-I1-GC
07/02/2024
Objection resolved — Addressed
05/22/2024
Permit issued — General Construction
B00930112-I1-GC
05/21/2024
Permit issued — General Construction
B00930112-I1-GC
05/17/2024
Permit issued — Sprinklers
B00930112-S4-EW-SP
05/15/2024
Permit issued — Plumbing
B00930112-S3-PL
05/14/2024
Permit issued — Structural
B00930112-S1-ST
05/14/2024
Permit issued — Foundation
B00930112-S2-FO
04/11/2024
Violation issued (HPD, open)
A
04/03/2024
Objection raised — Scope
03/28/2024
Filed — Alteration CO
APPLICATION FILED FOR THE INSTALLATION OF A NEW SPRINKLER SYSTEM TO AN EXISTING (3) FAMILY BUILDING IN CONJUNCTION WITH HORIZONTAL ENLARGEMENT & GUT/REHAB FILED UNDER ALT-1 JOB# B00930112-I1.
B00930112-S5
02/22/2024
Objection resolved — Addressed
02/22/2024
Objection resolved — Addressed
02/14/2024
Objection resolved — Addressed
02/08/2024
Objection raised — Scope
02/08/2024
Objection raised — Fire_Protection
01/31/2024
Objection resolved — Addressed
01/31/2024
Objection resolved — Addressed
01/31/2024
Objection resolved — Addressed
01/31/2024
Objection resolved — Addressed
01/31/2024
Objection resolved — Addressed
01/31/2024
Objection resolved — Addressed
01/31/2024
Objection resolved — Addressed
01/31/2024
Objection resolved — Addressed
01/31/2024
Objection resolved — Addressed
01/29/2024
Objection raised — Scope
01/29/2024
Objection resolved — Addressed
01/29/2024
Special inspection requirement — Seismic Isolation Systems
XIUCHENG LI
01/29/2024
Special inspection requirement — Fire-Resistant Penetrations and Joints
JOMO CHARLES
01/26/2024
Objection raised — Zoning
01/25/2024
Objection raised — Other
01/25/2024
Objection resolved — Addressed
01/23/2024
Objection resolved — Addressed
01/22/2024
Objection raised — Scope
01/22/2024
Objection resolved — Addressed
Latest 60 of 123 events.
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWSprinklersPermit IssuedFULTON PLBG & HTG CORP09/10/2026
DOB NOWGeneral ConstructionPermit IssuedJ3R BUILDERS CONTRACTING03/31/2026
DOB NOWMechanical SystemsPermit IssuedHERTLER NADILE PLMBG & HT02/06/2026
DOB NOWSprinklersPermit IssuedFULTON PLBG & HTG CORP08/25/2025
DOB NOWGeneral ConstructionPermit IssuedJ3R BUILDERS CONTRACTING05/02/2025
DOB NOWFoundationSigned-offJ3R BUILDERS CONTRACTING05/02/2025
DOB NOWSprinklersPermit IssuedFULTON PLBG & HTG CORP04/21/2025
DOB NOWPlumbingPermit IssuedHERTLER NADILE P & H, INC04/15/2025
DOB NOWSolarSigned-offACCORD POWER INC12/06/2024
DOB NOWGeneral ConstructionPermit IssuedJ3R BUILDERS CONTRACTING09/30/2024
DOB NOWGeneral ConstructionPermit IssuedJ3R BUILDERS CONTRACTING05/22/2024
DOB NOWGeneral ConstructionPermit IssuedJ3R BUILDERS CONTRACTING05/21/2024
DOB NOWSprinklersPermit IssuedFULTON PLBG & HTG CORP05/17/2024
DOB NOWPlumbingPermit IssuedHERTLER NADILE P & H, INC05/15/2024
DOB NOWStructuralSigned-offJ3R BUILDERS CONTRACTING05/14/2024
DOB NOWFoundationSigned-offJ3R BUILDERS CONTRACTING05/14/2024
1 project · most recent 03/28/2024
Heating and Air Conditioning Systems Ventilation Systems
FiledStatusContractorScopeMake / Model / Capacity
03/28/2024Permit IssuedJ3R BUILDERS CONTRACTINGHeating and Air Conditioning Systems, Ventilation Systems
Heat / Cool
Fujitsu AC-2-1, AC-2-2, AC-2-3, AC-3-3, AC-4 = ADUH09LUAS1 9,000 BTU · Vrf Indoor ×5
AC-1-1, AC-1-2, AC-1-3 = ADUH12LUAS1 12,000 BTU ×3
AC-3-1, AC-3-2 = ADUH18LUAS1 18,000 BTU · Fan Coil Indoor ×2
ACC-1-1 = A0U45RLXFZ 45,000 BTU · Condensing Unit ×1
ACC-2-1 = AOU36RLXFZH 36,000 BTU · Condensing Unit ×1
ACC-3-1 = AOU36RLXFZH 35,200 BTU · Condensing Unit ×1
ACC-3-2 = AOU18RLXFZH 35,200 BTU · Condensing Unit ×1
Ventilation
Fantech TEF-1, TEF-2, TEF-3, TEF-4 = PRO-100 50 CFM · Exhaust Fan ×4
KEF-1 = PRO-150 100 CFM · Kitchen Exhaust ×1
KEF-2 = FG-8 300 CFM · Kitchen Exhaust ×1
Fujitsu AC-1-4 = ADUHD07LUAS1 7,000 BTU ×1
1 project · most recent 03/28/2024
Sprinkler System
FiledStatusContractorScope
03/28/2024Permit IssuedFULTON PLBG & HTG CORPSprinkler System
1 project · most recent 03/28/2024
Gas Storm Water/Sanitary
FiledStatusContractorScope
03/28/2024Permit IssuedHERTLER NADILE P & H, INCGas, Storm, Water/Sanitary
2 projects · most recent 03/25/2026
General Wiring
FiledStatusContractorScope
03/25/2026CompleteACCORD POWER ELECTRIC LLC—
06/08/2023Permit IssuedNAPSTAR ELECTRIC INCGeneral Wiring
1 project · most recent 03/28/2024
Steel
FiledStatusContractorScope
03/28/2024Permit IssuedFULTON PLBG & HTG CORPSteel
▾Field Inspections (DOB CAP) — 5
DateTypeResultReport
04/03/2026Pass-Final CND-Occupancy InspectionPassView ↗
08/19/2025Certified Gas-Gas-Piping-RoughingCertifiedView ↗
08/13/2025Certified Storm Drainage-ST-Piping-RoughingCertifiedView ↗
08/13/2025Certified Water and Sanitary-WS-Sanitary Piping-RoughingCertifiedView ↗
08/11/2025Certified Remove/Cap - work done in accordance with codeCertifiedView ↗
▾Special Inspection Requirements (DOB NOW) — 34
DateRequirementInspectorRole
10/18/2024Structural Stability – Alterations of existing buildingsMalathi Ananthakrishnanspecial
10/18/2024Air barrier - visual inspectionMalathi Ananthakrishnanenergy_progress
10/18/2024Energy Code Compliance InspectionsMalathi Ananthakrishnanprogress
10/18/2024Fire-Resistant Penetrations and JointsMalathi Ananthakrishnanspecial
10/18/2024FinalMalathi Ananthakrishnanprogress
01/29/2024Seismic Isolation SystemsXIUCHENG LIspecial
01/29/2024Fire-Resistant Penetrations and JointsJOMO CHARLESspecial
01/18/2024Construction Operations Influencing Adjacent StructuresJOMO CHARLESspecial
01/10/2024MeteringJOMO CHARLESenergy_progress
01/02/2024Sprinkler SystemsJOMO CHARLESspecial
12/13/2023Construction Operations Influencing Adjacent StructuresJOMO CHARLESspecial
12/13/2023Excavations - Sheeting, Shoring, and BracingJOMO CHARLESspecial
12/13/2023Structural Stability – Alterations of existing buildingsJOMO CHARLESspecial
12/13/2023Concrete - Cast-In-PlaceJOMO CHARLESspecial
12/06/2023FinalJOMO CHARLESprogress
12/06/2023Footing and FoundationJOMO CHARLESprogress
12/05/2023FinalJOMO CHARLESprogress
12/05/2023Structural Cold-Formed SteelJOMO CHARLESspecial
12/05/2023Structural Steel - DetailsJOMO CHARLESspecial
12/05/2023Structural Stability – Alterations of existing buildingsJOMO CHARLESspecial
10/12/2023Exterior Insulation and Finish Systems (EIFS)JOMO CHARLESspecial
10/12/2023Fire-Resistant Penetrations and JointsJOMO CHARLESspecial
10/12/2023Fenestration and door U-factor and product ratingsPHILIP TOSCANOenergy_progress
10/12/2023Air barrier - visual inspectionJOMO CHARLESenergy_progress
10/12/2023Permanent certificateJOMO CHARLESenergy_progress
Latest 25 of 34.
▾Documents — 45 on file (BIS + DOB NOW)
▸Plans & Drawings7
▸DOB NOWPlans/Sketch7
08/26/2026B00930112-S2Request digital key ↗
08/26/2026B00930112-S1Request digital key ↗
08/26/2026B00930112-S5Request digital key ↗
Showing 3 of 7 on file for this type
▸Zoning, Tax Lot & Property Records2
▸DOB NOWZD1: DOB Zoning Diagram1
08/13/2026B00930112-I1Open ↗
▸DOB NOWZoning Exhibit form (1-5)1
08/13/2026B00930112-I1Open ↗
▸Seals & Professional Certifications23
▸DOB NOWSpecial Inspector Seal & Signature8
09/01/2026B00930112-I1Open ↗
09/01/2026B00930112-I1Open ↗
08/29/2026B00930112-S2Open ↗
Showing 3 of 8 on file for this type
▸DOB NOWProgress Inspector Seal & Signature8
09/01/2026B00930112-I1Open ↗
09/01/2026B00930112-I1Open ↗
09/01/2026B00930112-I1Open ↗
Showing 3 of 8 on file for this type
▸DOB NOWDPL-1: Design Professional Seal & Signature7
08/26/2026B00930112-S5Open ↗
08/26/2026B00930112-S4Open ↗
08/26/2026B00930112-S3Open ↗
Showing 3 of 7 on file for this type
▸Safety & Tenant Protection1
▸DOB NOWStreet Tree Checklist1
08/13/2026B00930112-I1Open ↗
▸Environmental & Asbestos6
▸DOB NOWDEP ACP-5: Asbestos Assessment Report6
08/26/2026B00930112-S2Open ↗
08/26/2026B00930112-S4Open ↗
08/26/2026B00930112-S3Open ↗
Showing 3 of 6 on file for this type
▸Approvals, Objections & Sign-offs1
▸DOB NOWUtility Company Final Acceptance Letter1
08/23/2026B01129238-I1Open ↗
▸Other Documents5
▸DOB NOWPlot Diagram2
08/13/2026B00930112-S2Open ↗
08/13/2026B00930112-I1Open ↗
▸DOB NOWLocal Law 92/94 of 2019 Sustainable Roof Zone1
08/13/2026B00930112-I1Open ↗
▸DOB NOWProperty Ownership Certification1
08/26/2026B00930112-I1Open ↗
▸DOB NOWSite Survey: Initial1
08/13/2026B00930112-I1Open ↗