← Back
Two family brick
624 EMPIRE BOULEVARD
BROOKLYN · BIN 3035210
💬 Discuss this project
1930Year Built
2Stories
B1Building Class
R7-1Zoning
5,184 sfGross Floor Area
2Units
0 Open ViolationsFDNY Report ↗
Two family brick · Owner of record: KEILIM MANAGEMENT LLC · 3,330 sf lot · 1.56 FAR built · Flood zone X
Locations of Work
Plumbing
Floor 21p · 1 filing · 20 docs
Floor 11p · 1 filing · 20 docs
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
KEILIM MANAGEMENT1203/22/2026
▾Sales History (ACRIS)
DatePriceUnitSeller → Buyer$/sf
05/13/2020$1.5M—Private party → KEILIM MANAGEMENT LLC$285/sf building
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
EDWARD C. HICKS RA307/13/2021
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
ADVANCED BUILDERS SERVICES303/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
AL PLUMBING & CONT. INCPlumbing107/08/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
AEG, P.C.1846307/13/2021
Building Lifecycle
All (22)Filed (3)Permit Issued (1)Violation (4)Objection (2)Special Inspection (12)
07/14/2021
Special inspection requirement — Fire-Resistant Penetrations and Joints
Yousuf Tai
07/14/2021
Special inspection requirement — Fire-Resistance Rated Construction
Yousuf Tai
07/14/2021
Special inspection requirement — Energy Code Compliance Inspections
Yousuf Tai
07/14/2021
Special inspection requirement — Maintenance information
Yousuf Tai
07/13/2021
Filed — Alteration
Plumbing specifications and work types filed in conjunction with Alt. II job number 340738884
B00383073-P2
06/08/2021
Special inspection requirement — Fire-Resistant Penetrations and Joints
Yousuf Tai
06/08/2021
Special inspection requirement — Energy Code Compliance Inspections
Yousuf Tai
06/08/2021
Special inspection requirement — Fire-Resistance Rated Construction
Yousuf Tai
06/08/2021
Special inspection requirement — Maintenance information
Yousuf Tai
01/25/2021
Objection resolved — Addressed
12/09/2020
Objection raised — Scope
12/08/2020
Filed — Alteration
Plumbing specifications and work types filed in conjunction with Alt. II job number 340738884
B00383073-P1
11/20/2020
Special inspection requirement — Fire-Resistant Penetrations and Joints
Yousuf Tai
11/20/2020
Special inspection requirement — Energy Code Compliance Inspections
Yousuf Tai
11/20/2020
Special inspection requirement — Fire-Resistance Rated Construction
Yousuf Tai
11/20/2020
Special inspection requirement — Maintenance information
Yousuf Tai
10/28/2020
Permit issued — Plumbing
B00383073-I1-PL
08/19/2020
Filed — Alteration
Plumbing specifications and work types filed in conjunction with Alt. II job number 340738884
B00383073-I1
07/13/2016
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
04/22/2016
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
04/20/2016
Violation issued (ECB, closed)
Construction
08/23/2015
Violation issued (DOB, closed)
V%*-DOB VIOLATION - DISMISSED
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWPlumbingSigned-offAL PLUMBING & CONT. INC10/28/2020
BISOTISSUEDSOL DEVELOPERS LLC01/27/2021
BISOTISSUEDBROOKSTONE DEVELOPERS LLC08/12/2020
1 project · most recent 07/13/2021
Gas Water/Sanitary
FiledStatusContractorScope
07/13/2021Signed-offAL PLUMBING & CONT. INCGas, Water/Sanitary
1 project · most recent 10/21/2020
FiledStatusContractorScope
10/21/2020Permit IssuedGREEN STAR ELECTL CONT IN—
▾Special Inspection Requirements (DOB NOW) — 12
DateRequirementInspectorRole
07/14/2021Fire-Resistant Penetrations and JointsYousuf Taispecial
07/14/2021Fire-Resistance Rated ConstructionYousuf Taiprogress
07/14/2021Energy Code Compliance InspectionsYousuf Taiprogress
07/14/2021Maintenance informationYousuf Taienergy_progress
06/08/2021Fire-Resistant Penetrations and JointsYousuf Taispecial
06/08/2021Energy Code Compliance InspectionsYousuf Taiprogress
06/08/2021Fire-Resistance Rated ConstructionYousuf Taiprogress
06/08/2021Maintenance informationYousuf Taienergy_progress
11/20/2020Fire-Resistant Penetrations and JointsYousuf Taispecial
11/20/2020Energy Code Compliance InspectionsYousuf Taiprogress
11/20/2020Fire-Resistance Rated ConstructionYousuf Taiprogress
11/20/2020Maintenance informationYousuf Taienergy_progress
▾Documents — 50 on file (BIS + DOB NOW)
▸Plans & Drawings3
▸DOB NOWPlans/Sketch - Plumbing3
09/02/2026B00383073-I1Request digital key ↗
08/15/2026B00383073-P2Request digital key ↗
08/15/2026B00383073-P1Request digital key ↗
▸Applications & Permits7
▸BISWORK PERMIT APPLICATION4
02/17/2021340738884Open ↗
01/19/2021340738884Open ↗
01/19/2021340738884Open ↗
Showing 3 of 4 on file for this type
▸BISPLAN / WORK APPROVAL APPLICATION1
07/16/2020340738884Open ↗
▸BISPARTIAL DEMO: 10-DAY NOTICE (FOR AL/EW-OT PERMITS)1
08/07/2020340738884Open ↗
▸BISPARTIAL DEMO PLAN & DS1 (FOR AL/EW-OT PERMITS)1
08/07/2020340738884Open ↗
▸Zoning, Tax Lot & Property Records1
▸BISRESTRICTION: RESTRICTIVE DECLARATION1
01/25/2021340738884Open ↗
▸Seals & Professional Certifications17
▸DOB NOWProgress Inspector Seal & Signature9
08/31/2026B00383073-P1Open ↗
08/31/2026B00383073-P1Open ↗
08/31/2026B00383073-P1Open ↗
Showing 3 of 9 on file for this type
▸DOB NOWDPL-1: Design Professional Seal & Signature3
08/13/2026B00383073-I1Open ↗
08/13/2026B00383073-P1Open ↗
08/13/2026B00383073-P2Open ↗
▸DOB NOWSpecial Inspector Seal & Signature3
08/31/2026B00383073-P1Open ↗
08/25/2026B00383073-P2Open ↗
08/23/2026B00383073-I1Open ↗
▸BISAPPLICANT OWNER SIGNATURE1
07/16/2020340738884Open ↗
▸BISTECHNICAL REPORT STATEMENT OF RESPONSIBILITY1
07/16/2020340738884Open ↗
▸Safety & Tenant Protection1
▸BISTenant Protection Plan and Notes1
07/16/2020340738884Open ↗
▸Environmental & Asbestos4
▸DOB NOWDEP ACP-5: Asbestos Assessment Report3
08/13/2026B00383073-I1Open ↗
08/13/2026B00383073-P1Open ↗
08/13/2026B00383073-P2Open ↗
▸BISASBESTOS: CERTIFICATION (DEP ACP5)1
07/16/2020340738884Open ↗
▸Energy Compliance6
▸BISTECHNICAL REPORT: ENERGY CODE - RESPONSIBILITY4
06/24/2021340738884Open ↗
06/24/2021340738884Open ↗
08/07/2020340738884Open ↗
Showing 3 of 4 on file for this type
▸BISAS-BUILT ENERGY ANALYSIS (EN2)1
06/24/2021340738884Open ↗
▸BISTECHNICAL REPORT STATEMENT OF RESPONSIBILITY FOR ENERGY CODE PROGRESS INSPECTIONS1
07/16/2020340738884Open ↗
▸Inspections & Test Reports4
▸BISTECHNICAL REPORT: RESPONSIBILITY4
06/24/2021340738884Open ↗
06/24/2021340738884Open ↗
08/07/2020340738884Open ↗
Showing 3 of 4 on file for this type
▸Approvals, Objections & Sign-offs4
▸BISLETTERS - SUPPORTING DOCUMENTATION2
01/19/2021340738884Open ↗
01/19/2021340738884Open ↗
▸BISSUPERSEDING LETTER1
02/17/2021340738884Open ↗
▸BISCERTIFICATE OF OCCUPANCY/LOC: REQUEST1
06/24/2021340738884Open ↗
▸Cost, Insurance & Ownership2
▸BISCOST AFFIDAVIT1
08/12/2020340738884Open ↗
▸BISCOST AFFIDAVIT (FINAL): PW31
06/24/2021340738884Open ↗
▸Filing & Intake Forms1
▸BISADDITIONAL INFORMATION1
01/25/2021340738884Open ↗