| Owner | Filings | Most Recent |
|---|---|---|
| UGB CONSTRUCTION | 2 | 06/27/2026 |
| Firm | Filings | Most Recent |
|---|---|---|
| PALETTE ARCHITECTURE | 8 | 04/28/2026 |
| ROSENTHAL ENGINEERING PLLC | 8 | 12/05/2025 |
| BUILDING CONSULTING ENGINEERING | 1 | 05/24/2024 |
| HANSEN ENGINEERING, PC | 3 | 12/01/2023 |
| SILMAN | 3 | 11/30/2023 |
| ELR MORGAN LLC | 2 | 09/11/2023 |
| SOUTH BAY ENGINEERING PLLC | 1 | 05/05/2023 |
| Firm | Trade | Roles | Most Recent |
|---|---|---|---|
| UGB CONSTRUCTION INC | General Contractor | 14 | 06/27/2026 |
| PRIME PIPING & HEATING IN | Fire Protection | 2 | 06/27/2026 |
| PRIME PIPING & HEATING IN | Plumbing | 2 | 06/27/2026 |
| IR CONTRACTING INC | General Contractor | 1 | 06/27/2026 |
| Agency | License # | Filings | Most Recent |
|---|---|---|---|
| HRF SERVICES CORP | 5616 | 15 | 04/28/2026 |
| Source | Work Type | Status | Applicant | Issued |
|---|---|---|---|---|
| DOB NOW | Plumbing | Permit Issued | PRIME PIPING & HEATING IN | 10/21/2025 |
| DOB NOW | General Construction | Permit Issued | IR CONTRACTING INC | 10/16/2025 |
| DOB NOW | Support of Excavation | Signed-off | IR CONTRACTING INC | 09/29/2025 |
| DOB NOW | Mechanical Systems | Signed-off | UGB CONSTRUCTION INC | 09/18/2025 |
| DOB NOW | Curb Cut | Permit Issued | UGB CONSTRUCTION INC | 08/05/2025 |
| DOB NOW | Curb Cut | Permit Issued | UGB CONSTRUCTION INC | 08/05/2025 |
| DOB NOW | Foundation | Signed-off | UGB CONSTRUCTION INC | 07/15/2025 |
| DOB NOW | Standpipe | Permit Issued | A M B MECHANICAL INC | 03/31/2025 |
| DOB NOW | Sprinklers | Permit Issued | A M B MECHANICAL INC | 03/31/2025 |
| DOB NOW | Support of Excavation | Signed-off | UGB CONSTRUCTION INC | 02/03/2025 |
| DOB NOW | Foundation | Signed-off | UGB CONSTRUCTION INC | 01/30/2025 |
| DOB NOW | Structural | Signed-off | UGB CONSTRUCTION INC | 01/07/2025 |
| DOB NOW | General Construction | Permit Issued | UGB CONSTRUCTION INC | 12/02/2024 |
| DOB NOW | General Construction | Permit Issued | UGB CONSTRUCTION INC | 10/03/2024 |
| DOB NOW | Plumbing | Permit Issued | PRIME PIPING & HEATING IN | 09/27/2024 |
| DOB NOW | Mechanical Systems | Signed-off | UGB CONSTRUCTION INC | 09/24/2024 |
| DOB NOW | Structural | Signed-off | UGB CONSTRUCTION INC | 09/24/2024 |
| DOB NOW | Construction Fence | Permit Issued | UGB CONSTRUCTION INC | 09/23/2024 |
| DOB NOW | General Construction | Permit Issued | UGB CONSTRUCTION INC | 05/15/2024 |
| DOB NOW | Structural | Signed-off | UGB CONSTRUCTION INC | 04/22/2024 |
| DOB NOW | Support of Excavation | Signed-off | UGB CONSTRUCTION INC | 01/24/2024 |
| DOB NOW | Foundation | Signed-off | UGB CONSTRUCTION INC | 01/23/2024 |
| DOB NOW | Foundation | Signed-off | UGB CONSTRUCTION INC | 08/28/2023 |
| DOB NOW | Support of Excavation | Signed-off | UGB CONSTRUCTION INC | 08/17/2023 |
| DOB NOW | Construction Fence | Permit Issued | UGB CONSTRUCTION INC | 07/24/2023 |
| DOB NOW | Construction Fence | Permit Issued | UGB CONSTRUCTION INC | 07/12/2023 |
| Filed | Status | Contractor | Scope | Make / Model / Capacity |
|---|---|---|---|---|
| 04/28/2026 | Permit Issued | IR CONTRACTING INC | Associated Ducts and Piping, Heating and Air Conditioning Systems, Ventilation Systems | Heat / Cool Mitsubishi Electric MXZ-SM36NAM2 36,000 BTU · Condensing Unit ×52 MMXZ-SM36NAM2 36,000 BTU · Vrf Outdoor ×28 MXZ-SM36NAM2, MMXZ-SM36NAM2 36,000 BTU · Condensing Unit ×22 PUHY-EP72TNU-A1 72,000 BTU · Vrf Outdoor ×4 MUZ-FS12NA 12,000 BTU · Condensing Unit ×3 MXZ-SM48NAM2 48,000 BTU · Condensing Unit ×2 PUY-A18NKA7 18,000 BTU · Condensing Unit ×3 MXZ-SM36NAM 36,000 BTU · Condensing Unit ×42 PUHY-P72TNU-A 72,000 BTU · Vrf Outdoor ×2 MXZ-SM48NAM 48,000 BTU · Condensing Unit ×1 Ventilation Greenheck G-103-VG 995 CFM · Exhaust Fan ×9 G-098-VG 625 CFM · Exhaust Fan ×6 G-103HP-VG 390 CFM · Exhaust Fan ×6 BSQ-160-10 3,600 CFM · Exhaust Fan ×3 BSQ-180-30 5,600 CFM · Exhaust Fan ×3 G-097-VG 225 CFM · Exhaust Fan ×3 G-100HP-VG 690 CFM · Exhaust Fan ×3 Aldes A-8 300 CFM · Exhaust Fan ×3 Ducts & Piping __Junk__ Associate Ducts and Piping 1 BTU · Ductwork ×3 |
| Filed | Status | Contractor | Scope |
|---|---|---|---|
| 04/28/2026 | Permit Issued | PRIME PIPING & HEATING IN | Sprinkler System |
| Filed | Status | Contractor | Scope |
|---|---|---|---|
| 04/28/2026 | Permit Issued | A M B MECHANICAL INC | Storm, Water/Sanitary |
| Filed | Status | Contractor | Scope |
|---|---|---|---|
| 02/06/2025 | Complete | FIBERTEK DATA & ELEC CORP | — |
| 02/03/2025 | Complete | FIBERTEK DATA & ELEC CORP | — |
| 11/06/2024 | Permit Issued | POWER DIRECT ELECTRIC INC | — |
| Filed | Status | Contractor | Scope |
|---|---|---|---|
| 04/28/2026 | Permit Issued | A M B MECHANICAL INC | Concrete |
| Filed | Status | Contractor | Scope |
|---|---|---|---|
| 09/11/2023 | — | — | Sidewalk Shed |
| Date | Type | Result | Report |
|---|---|---|---|
| 02/20/2026 | Pass-Final CND-Occupancy Inspection | Pass | View ↗ |
| 02/06/2026 | Pass-Final PL - Up to 9 Requested Floors | Pass | View ↗ |
| 01/16/2026 | Fail-Final Curb Cut Non-Directive 14 | Fail | View ↗ |
| 01/16/2026 | Pass-Final CND-Occupancy Inspection | Pass | View ↗ |
| 11/12/2025 | Certified Storm Drainage-ST-Piping-Roughing | Certified | View ↗ |
| 11/12/2025 | Certified Water and Sanitary-WS-Sanitary Piping-Roughing | Certified | View ↗ |
| 11/05/2025 | Pass-Final PL - Up to 3 Requested Floors | Pass | View ↗ |
| 10/24/2025 | Certified Storm Drainage-ST-Piping-Roughing | Certified | View ↗ |
| 10/24/2025 | Certified Storm Drainage-ST-Piping-Underground | Certified | View ↗ |
| 10/24/2025 | Certified Water and Sanitary-WS-Sanitary Piping-Roughing | Certified | View ↗ |
| 10/24/2025 | Certified Water and Sanitary-WS-Sanitary Piping-Underground | Certified | View ↗ |
| 10/23/2025 | Certified Sprinkler-Dry Pipe Valve (SP)-Dry Pipe Valve Test | Certified | View ↗ |
| 10/23/2025 | Certified Sprinkler-SP-Fixtures-Finish | Certified | View ↗ |
| 10/23/2025 | Certified StandPipe-Fire Pump (SD)-Fire Pump Test | Certified | View ↗ |
| 10/23/2025 | Certified StandPipe-SD-Fixtures-Finish-SD | Certified | View ↗ |
| 10/20/2025 | Certified Sprinkler-SP-Piping Dry/Wet-Hydrostatic Test | Certified | View ↗ |
| 10/20/2025 | Certified StandPipe-SD-Piping-Hydrostatic Test | Certified | View ↗ |
| 08/04/2025 | Certified Storm Drainage-ST-Piping-Roughing | Certified | View ↗ |
| 08/04/2025 | Certified Water and Sanitary-WS-Sanitary Piping-Roughing | Certified | View ↗ |
| 05/22/2025 | Certified Water and Sanitary-WS-Sanitary Piping-Roughing | Certified | View ↗ |
| 03/10/2025 | Certified Storm Drainage-ST-Piping-Roughing | Certified | View ↗ |
| 10/16/2024 | Certified Storm Drainage-ST-Piping-Underground | Certified | View ↗ |
| 10/02/2024 | Certified Storm Drainage-ST-Piping-Underground | Certified | View ↗ |
| 10/02/2024 | Certified Water and Sanitary-WS-Sanitary Piping-Underground | Certified | View ↗ |
| Date | Requirement | Inspector | Role |
|---|---|---|---|
| 05/12/2026 | Tenant Protection Plan Compliance | FAHAD FATEH | special |
| 05/12/2026 | Fire-Resistant Penetrations and Joints | FAHAD FATEH | special |
| 05/12/2026 | Energy Code Compliance Inspections | FAHAD FATEH | progress |
| 05/12/2026 | Fire-Resistance Rated Construction | FAHAD FATEH | progress |
| 05/12/2026 | Lighting in dwelling units | FAHAD FATEH | energy_progress |
| 05/12/2026 | Protection of exposed foundation insulation | FAHAD FATEH | energy_progress |
| 05/12/2026 | Exterior lighting power | FAHAD FATEH | energy_progress |
| 05/12/2026 | Fenestration air leakage | FAHAD FATEH | energy_progress |
| 05/12/2026 | Lighting controls | FAHAD FATEH | energy_progress |
| 05/12/2026 | Maintenance information | FAHAD FATEH | energy_progress |
| 05/12/2026 | Air barrier - visual inspection | FAHAD FATEH | energy_progress |
| 05/12/2026 | Metering | FAHAD FATEH | energy_progress |
| 05/12/2026 | Electrical motors and elevators | FAHAD FATEH | energy_progress |
| 05/12/2026 | Interior lighting power | FAHAD FATEH | energy_progress |
| 05/12/2026 | Air barrier — testing | FAHAD FATEH | energy_progress |
| 05/12/2026 | Fenestration areas | FAHAD FATEH | energy_progress |
| 05/12/2026 | Fenestration and door U-factor and product ratings | FAHAD FATEH | energy_progress |
| 05/12/2026 | Insulation placement and R values | FAHAD FATEH | energy_progress |
| 12/23/2025 | Fire-Resistant Penetrations and Joints | FAHAD FATEH | special |
| 12/23/2025 | HVAC-R and service water heating system controls | FAHAD FATEH | energy_progress |
| 12/23/2025 | Maintenance information | FAHAD FATEH | energy_progress |
| 12/23/2025 | HVAC-R and service water heating equipment | FAHAD FATEH | energy_progress |
| 12/23/2025 | HVAC-R and service water piping design and insulation | FAHAD FATEH | energy_progress |
| 12/23/2025 | Shutoff dampers | FAHAD FATEH | energy_progress |
| 12/23/2025 | Final | FAHAD FATEH | progress |