← Back
City residence, one family
629 AVENUE T
BROOKLYN · BIN 3190491
💬 Discuss this project
1930Year Built
2.5Stories
A4Building Class
R5Zoning
3,463 sfGross Floor Area
1Units
Rent Stabilized11 Open Violations 10 unresolved · 1 paperwork only ▸FDNY Report ↗
City residence, one family · 2,310 sf lot · 1.5 FAR built · Flood zone X500
Locations of Work
Architecture
Roof4p · 2 filings · 20 docs
Floor 215p · 1 filing · 20 docs
Floor 115p · 1 filing · 20 docs
Cellar15p · 1 filing · 20 docs
Basement2p · 1 filing · 13 docs
▾Sales History (ACRIS)
DatePriceUnitSeller → Buyer$/sf
10/28/2021$2.4M—Private party → Private party$693/sf building
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
NY BUILDING ASSOCIATES INC406/03/2026
MGM CREATIONS ARCHITECTURE710/01/2025
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
A2ZCM803/21/2026
S R SOLAR DESIGN203/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
BUILDERS JOSEPH AND SONSGeneral Contractor607/08/2026
MOD CONSULTANTS LLCGeneral Contractor303/21/2026
KATAN P & H INCPlumbing207/08/2026
EMES SOLAR INCGeneral Contractor104/09/2026
NESPO LLCGeneral Contractor104/09/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
NKM ENGINEERING PLLC6244406/03/2026
MGM CREATIONS ARCHITECTUR7979310/01/2025
STEEL CORE ENGINEERING PL1098310/01/2025
Building Lifecycle
All (142)Filed (11)Permit Issued (10)Signed Off (3)Violation (17)Inspection (5)Objection (66)Special Inspection (30)
06/03/2026
Filed — Alteration
PROPOSED NEW EXTERIOR STAIR WITH FOUNDATION FROM 1ST FLOOR TO CELLAR. CONSTRUCTION OF TWO NEW EXTERIOR WALLS WITH FOUNDATIONS AT EXISTING 2.5-STORY BUILDING. PARTITION WORK AS PER PLANS. NO CHANGE IN USE OR OCCUPANCY.
B01324758-P1
06/03/2026
Special inspection requirement — Footing and Foundation
NARESH MAHANGU
06/03/2026
Special inspection requirement — Concrete - Cast-In-Place
NARESH MAHANGU
06/03/2026
Special inspection requirement — Final
Lester Katz
05/01/2026
Violation issued (HPD, open)
A
03/26/2026
Signed off — Alteration
INSTALLATION OF SOLAR PANELS ON EXISTING ROOF. NO CHANGE IN USE, OCCUPANCY, OR EGRESS. NO CHANGE IN BULK
B01301159-I1
03/20/2026
Special inspection requirement — Energy Code Compliance Inspections
NARESH MAHANGU
03/20/2026
Special inspection requirement — Air barrier - visual inspection
NARESH MAHANGU
03/20/2026
Special inspection requirement — Final
NARESH MAHANGU
03/20/2026
Special inspection requirement — Fire-Resistant Penetrations and Joints
NARESH MAHANGU
03/17/2026
Filed — Alteration
INSTALLATION OF SOLAR PANELS ON EXISTING ROOF. NO CHANGE IN USE, OCCUPANCY, OR EGRESS. NO CHANGE IN BULK
B01301159-P1
03/16/2026
Special inspection requirement — Fire-Resistant Penetrations and Joints
NARESH MAHANGU
03/16/2026
Special inspection requirement — Final
NARESH MAHANGU
03/16/2026
Special inspection requirement — Energy Code Compliance Inspections
NARESH MAHANGU
03/16/2026
Special inspection requirement — Air barrier - visual inspection
NARESH MAHANGU
01/05/2026
Permit issued — Foundation
B01324758-I1-GC-CX
12/17/2025
Objection resolved — Addressed
12/12/2025
Objection raised — Other
12/11/2025
Objection resolved — Addressed
12/11/2025
Objection resolved — Addressed
12/11/2025
Objection resolved — Addressed
12/11/2025
Objection resolved — Addressed
12/10/2025
Objection raised — Structural
12/10/2025
Objection raised — Structural
12/10/2025
Objection raised — Structural
12/10/2025
Objection raised — Admin
12/08/2025
Objection raised — Zoning
12/08/2025
Objection resolved — Addressed
12/08/2025
Objection raised — Structural
12/08/2025
Objection resolved — Addressed
12/04/2025
Objection resolved — Addressed
12/04/2025
Objection resolved — Addressed
12/04/2025
Objection resolved — Addressed
12/04/2025
Objection resolved — Addressed
12/04/2025
Objection resolved — Addressed
12/04/2025
Objection resolved — Addressed
12/02/2025
Objection raised — Zoning
12/02/2025
Objection raised — Structural
12/02/2025
Objection raised — Structural
12/02/2025
Objection raised — Structural
12/02/2025
Objection raised — Zoning
12/02/2025
Objection resolved — Addressed
12/02/2025
Objection raised — Structural
12/02/2025
Objection raised — Structural
12/01/2025
Filed — Alteration
PROPOSED NEW EXTERIOR STAIR WITH FOUNDATION FROM 1ST FLOOR TO CELLAR. CONSTRUCTION OF TWO NEW EXTERIOR WALLS WITH FOUNDATIONS AT EXISTING 2.5-STORY BUILDING. PARTITION WORK AS PER PLANS. NO CHANGE IN USE OR OCCUPANCY.
B01324758-I1
11/28/2025
Special inspection requirement — Concrete - Cast-In-Place
NARESH MAHANGU
11/25/2025
Special inspection requirement — Final
Lester Katz
11/25/2025
Special inspection requirement — Footing and Foundation
NARESH MAHANGU
11/20/2025
Violation issued (HPD, open)
I
10/30/2025
Permit issued — Solar
B01301159-I1-SL
10/23/2025
Filed — Alteration
INSTALLATION OF SOLAR PANELS ON EXISTING ROOF. NO CHANGE IN USE, OCCUPANCY, OR EGRESS. NO CHANGE IN BULK
B01301159-I1
10/09/2025
Special inspection requirement — Fenestration and door U-factor and product ratings
GABRIEL GINGISHVILI
10/09/2025
Special inspection requirement — Fire-Resistant Penetrations and Joints
GABRIEL GINGISHVILI
10/09/2025
Special inspection requirement — Structural Stability – Alterations of existing buildings
Alexander Sheyman
10/09/2025
Special inspection requirement — Energy Code Compliance Inspections
GABRIEL GINGISHVILI
10/09/2025
Special inspection requirement — Fire-Resistance Rated Construction
GABRIEL GINGISHVILI
10/09/2025
Special inspection requirement — Insulation placement and R values
GABRIEL GINGISHVILI
10/09/2025
Special inspection requirement — Air barrier - visual inspection
GABRIEL GINGISHVILI
10/09/2025
Special inspection requirement — Fenestration areas
GABRIEL GINGISHVILI
10/09/2025
Special inspection requirement — Interior lighting power
GABRIEL GINGISHVILI
Latest 60 of 142 events.
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWFoundationPermit IssuedNESPO LLC01/05/2026
DOB NOWSolarSigned-offEMES SOLAR INC10/30/2025
DOB NOWGeneral ConstructionPermit IssuedMOD CONSULTANTS LLC03/10/2025
DOB NOWPlumbingSigned-offKATAN P & H INC01/23/2024
DOB NOWGeneral ConstructionPermit IssuedBUILDERS JOSEPH AND SONS12/06/2022
DOB NOWPlumbingSigned-offKATAN P & H INC11/03/2022
DOB NOWGeneral ConstructionPermit IssuedBUILDERS JOSEPH AND SONS10/05/2022
DOB NOWGeneral ConstructionPermit IssuedBUILDERS JOSEPH AND SONS06/23/2022
DOB NOWGeneral ConstructionPermit IssuedBUILDERS JOSEPH AND SONS06/14/2022
DOB NOWConstruction FenceSigned-offBUILDERS JOSEPH AND SONS06/09/2022
1 job · most recent 10/01/2025
Gas Water/Sanitary
FiledStatusContractorScope
10/01/2025Signed-offKATAN P & H INCGas, Water/Sanitary
2 jobs · most recent 10/22/2025
General Wiring
FiledStatusContractorScope
10/22/2025CompleteB.P. ELECTRIC CORP—
01/20/2025CompleteIRWIN ELECTR'L CONTR'S, IGeneral Wiring
1 job · most recent 06/03/2026
FiledStatusContractorScope
06/03/2026Permit IssuedNESPO LLC3 scope_items
1 job · most recent 06/03/2026
Earthwork Tenant Protection Plan 72 Hour
FiledStatusContractorScope
06/03/2026Permit IssuedNESPO LLCEarthwork, Tenant Protection Plan 72 Hour
▾Field Inspections (DOB CAP) — 5
DateTypeResultReport
06/06/2025Pass-Final CND-Occupancy InspectionPassView ↗
01/08/2025Fail-Final CND-Occupancy InspectionFailView ↗
04/20/2023Certified Gas-Gas-Piping-RoughingCertifiedView ↗
04/18/2023Certified Remove/Cap - work done in accordance with codeCertifiedView ↗
11/16/2022Pass-Final PL - UndergroundPassView ↗
▾Special Inspection Requirements (DOB NOW) — 43
DateRequirementInspectorRole
06/03/2026Footing and FoundationNARESH MAHANGUprogress
06/03/2026Concrete - Cast-In-PlaceNARESH MAHANGUspecial
06/03/2026FinalLester Katzprogress
03/20/2026Energy Code Compliance InspectionsNARESH MAHANGUprogress
03/20/2026Air barrier - visual inspectionNARESH MAHANGUenergy_progress
03/20/2026FinalNARESH MAHANGUprogress
03/20/2026Fire-Resistant Penetrations and JointsNARESH MAHANGUspecial
03/16/2026Fire-Resistant Penetrations and JointsNARESH MAHANGUspecial
03/16/2026FinalNARESH MAHANGUprogress
03/16/2026Energy Code Compliance InspectionsNARESH MAHANGUprogress
03/16/2026Air barrier - visual inspectionNARESH MAHANGUenergy_progress
11/28/2025Concrete - Cast-In-PlaceNARESH MAHANGUspecial
11/25/2025FinalLester Katzprogress
11/25/2025Footing and FoundationNARESH MAHANGUprogress
10/09/2025Fenestration and door U-factor and product ratingsGABRIEL GINGISHVILIenergy_progress
10/09/2025Fire-Resistant Penetrations and JointsGABRIEL GINGISHVILIspecial
10/09/2025Structural Stability – Alterations of existing buildingsAlexander Sheymanspecial
10/09/2025Energy Code Compliance InspectionsGABRIEL GINGISHVILIprogress
10/09/2025Fire-Resistance Rated ConstructionGABRIEL GINGISHVILIprogress
10/09/2025Insulation placement and R valuesGABRIEL GINGISHVILIenergy_progress
10/09/2025Air barrier - visual inspectionGABRIEL GINGISHVILIenergy_progress
10/09/2025Fenestration areasGABRIEL GINGISHVILIenergy_progress
10/09/2025Interior lighting powerGABRIEL GINGISHVILIenergy_progress
10/09/2025Fenestration air leakageGABRIEL GINGISHVILIenergy_progress
05/14/2025Energy Code Compliance InspectionsGABRIEL GINGISHVILIprogress
Latest 25 of 43.
▾Documents — 100 on file (BIS + DOB NOW)
▸Plans & Drawings11
▸DOB NOWPlans/Sketch11
08/28/2026B00687191-P4Request digital key ↗
08/28/2026B00687191-S1Request digital key ↗
08/28/2026B00687191-P1Request digital key ↗
Showing 3 of 11 on file for this type
▸Zoning, Tax Lot & Property Records4
▸DOB NOWZD1: DOB Zoning Diagram3
08/13/2026B00687191-I1Open ↗
08/13/2026B00687191-P1Open ↗
08/13/2026B00687191-P4Open ↗
▸DOB NOWHouse Number Verification: TOPO Stamp1
08/13/2026B00687191-I1Open ↗
▸Seals & Professional Certifications52
▸DOB NOWProgress Inspector Seal & Signature33
09/30/2026B00687191-S2Open ↗
09/30/2026B00687191-S2Open ↗
09/30/2026B00687191-S2Open ↗
Showing 3 of 33 on file for this type
▸DOB NOWDPL-1: Design Professional Seal & Signature11
08/20/2026B01301159-P1Open ↗
08/20/2026B01301159-I1Open ↗
08/16/2026B01324758-P1Open ↗
Showing 3 of 11 on file for this type
▸DOB NOWSpecial Inspector Seal & Signature8
09/02/2026B01301159-P1Open ↗
09/02/2026B01324758-P1Open ↗
09/02/2026B01301159-I1Open ↗
Showing 3 of 8 on file for this type
▸Trade Schedules & Equipment3
▸DOB NOWDEP: Sewer Certification (Sanitary/Storm)3
08/13/2026B00687191-P1Open ↗
08/13/2026B00687191-P4Open ↗
08/13/2026B00687191-I1Open ↗
▸Safety & Tenant Protection4
▸DOB NOWStreet Tree Checklist3
08/13/2026B00687191-P1Open ↗
08/13/2026B00687191-I1Open ↗
08/13/2026B00687191-P4Open ↗
▸DOB NOWStreet Trees Site Plan1
08/13/2026B00687191-I1Open ↗
▸Environmental & Asbestos9
▸DOB NOWDEP ACP-5: Asbestos Assessment Report9
08/20/2026B01301159-P1Open ↗
08/20/2026B01301159-I1Open ↗
08/13/2026B00687191-S2Open ↗
Showing 3 of 9 on file for this type
▸Energy Compliance1
▸DOB NOWEN2: As Built Energy Analysis1
08/13/2026B00687191-I1Open ↗
▸Inspections & Test Reports1
▸DOB NOWGeotechnical Report (BC 1803.6)1
08/13/2026B01324758-I1Open ↗
▸Approvals, Objections & Sign-offs1
▸DOB NOWUtility Company Final Acceptance Letter1
08/13/2026B01301159-I1Open ↗
▸Other Documents14
▸DOB NOWSite Survey: Initial3
08/13/2026B00687191-P1Open ↗
08/13/2026B00687191-P4Open ↗
08/13/2026B00687191-I1Open ↗
▸DOB NOWLocal Law 92/94 of 2019 Sustainable Roof Zone3
08/13/2026B00687191-P4Open ↗
08/13/2026B00687191-P1Open ↗
08/13/2026B00687191-I1Open ↗
▸DOB NOWPlot Diagram3
08/13/2026B00687191-P4Open ↗
08/13/2026B00687191-I1Open ↗
08/13/2026B00687191-P1Open ↗
▸DOB NOWProperty Ownership Certification3
08/13/2026B00687191-P4Open ↗
08/13/2026B00687191-P1Open ↗
08/13/2026B00687191-I1Open ↗
▸DOB NOWFinal Survey1
08/13/2026B00687191-I1Open ↗
▸DOB NOWProject Specific General Liability (PGL1)1
08/13/2026B00687191-I1Open ↗