One family attached or semi-detached
63-63 76 STREET
QUEENS · BIN 4069093
💬 Discuss this project
1950Year Built
2Stories
A5Building Class
R4BZoning
1,188 sfGross Floor Area
1Units
One family attached or semi-detached · 1,800 sf lot · 0.66 FAR built · Flood zone X
Locations of Work
Architecture
Cellar1p · 1 filing · 7 docs
▾Sales History (ACRIS)
DatePriceUnitSeller → Buyer$/sf
08/25/2021$752K—— → —$633/sf building
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
CD ARCHITECT STUDIO, LLP309/30/2022
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
CD ARCHITECT STUDIO603/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
R & M CONTRACTORS CORPGeneral Contractor303/21/2026
DH EAGLE PLBG & HTG INCPlumbing207/08/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
CD ARCHITECT STUDIO, LLP2573206/08/2022
Building Lifecycle
All (16)Filed (3)Permit Issued (3)Signed Off (3)Inspection (5)Special Inspection (2)
02/15/2023
Signed off — Alteration
SUBSEQUENT TO CORRECT FILING, THE CELLAR PROPOSED WASHER AND GAS DRYER ARE TO BE REMOVED FROM THIS APPLICATION AND WILL NOT BE INSTALLED, THIS APPLICATION IS TO LEGALIZE THE CEL. 2-FIXTURE BATH AND TO REPLACE THE 1ST FL. KITCHEN FIXTURES IN PLACE.
Q00743501-I1
02/13/2023
Inspection — Certified Remove/Cap - work done in accordance with code
Certified
View inspection ↗
02/09/2023
Inspection — Certified Water and Sanitary-WS-Fixtures-Finish
Certified
View inspection ↗
02/07/2023
Signed off — Alteration
SUBSEQUENT TO CORRECT FILING, THE CELLAR PROPOSED WASHER AND GAS DRYER ARE TO BE REMOVED FROM THIS APPLICATION AND WILL NOT BE INSTALLED, THIS APPLICATION IS TO LEGALIZE THE CEL. 2-FIXTURE BATH AND TO REPLACE THE 1ST FL. KITCHEN FIXTURES IN PLACE.
Q00743501-S1
02/02/2023
Inspection — Certified Water and Sanitary-WS-Fixtures-Finish
Certified
View inspection ↗
01/23/2023
Signed off — Alteration
Q00742813-I1
01/23/2023
Inspection — Pass-Final PL - Up to 3 Requested Floors
Pass
View inspection ↗
01/20/2023
Inspection — Pass-Final General Construction Non-Directive 14
Pass
View inspection ↗
10/07/2022
Permit issued — Plumbing
Q00743501-S1-PL
10/07/2022
Permit issued — Plumbing
Q00743501-I1-PL
09/30/2022
Filed — Alteration
SUBSEQUENT TO CORRECT FILING, THE CELLAR PROPOSED WASHER AND GAS DRYER ARE TO BE REMOVED FROM THIS APPLICATION AND WILL NOT BE INSTALLED, THIS APPLICATION IS TO LEGALIZE THE CEL. 2-FIXTURE BATH AND TO REPLACE THE 1ST FL. KITCHEN FIXTURES IN PLACE.
Q00743501-S1
06/23/2022
Permit issued — General Construction
Q00742813-I1-GC
06/08/2022
Filed — Alteration
SUBSEQUENT TO CORRECT FILING, THE CELLAR PROPOSED WASHER AND GAS DRYER ARE TO BE REMOVED FROM THIS APPLICATION AND WILL NOT BE INSTALLED, THIS APPLICATION IS TO LEGALIZE THE CEL. 2-FIXTURE BATH AND TO REPLACE THE 1ST FL. KITCHEN FIXTURES IN PLACE.
Q00743501-I1
06/08/2022
Filed — Alteration
Q00742813-I1
05/23/2022
Special inspection requirement — Fire-Resistant Penetrations and Joints
Peter D'Angelo
05/20/2022
Special inspection requirement — Fire-Resistant Penetrations and Joints
Peter D'Angelo
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWPlumbingSigned-offL.SPINA PLUMB & HTG INC10/07/2022
DOB NOWPlumbingSigned-offL.SPINA PLUMB & HTG INC10/07/2022
DOB NOWGeneral ConstructionSigned-offDISCIPLES CONSTRUCTION06/23/2022
BISOTISSUEDHOME OWNER04/23/2001
1 project · most recent 02/14/2023
General Wiring
FiledStatusContractorScope
02/14/2023CompleteKEVIN KEAVENY ELEC CO INCGeneral Wiring
▾Field Inspections (DOB CAP) — 5
DateTypeResultReport
02/13/2023Certified Remove/Cap - work done in accordance with codeCertifiedView ↗
02/09/2023Certified Water and Sanitary-WS-Fixtures-FinishCertifiedView ↗
02/02/2023Certified Water and Sanitary-WS-Fixtures-FinishCertifiedView ↗
01/23/2023Pass-Final PL - Up to 3 Requested FloorsPassView ↗
01/20/2023Pass-Final General Construction Non-Directive 14PassView ↗
▾Special Inspection Requirements (DOB NOW) — 2
DateRequirementInspectorRole
05/23/2022Fire-Resistant Penetrations and JointsPeter D'Angelospecial
05/20/2022Fire-Resistant Penetrations and JointsPeter D'Angelospecial
▾Documents — 11 on file (BIS + DOB NOW)
▸Plans & Drawings3
▸DOB NOWPlans/Sketch3
08/26/2026Q00742813-I1Request digital key ↗
08/25/2026Q00743501-I1Request digital key ↗
08/25/2026Q00743501-S1Request digital key ↗
▸Seals & Professional Certifications5
▸DOB NOWDPL-1: Design Professional Seal & Signature3
08/25/2026Q00743501-I1Open ↗
08/25/2026Q00743501-S1Open ↗
08/13/2026Q00742813-I1Open ↗
▸DOB NOWSpecial Inspector Seal & Signature2
08/25/2026Q00743501-I1Open ↗
08/23/2026Q00742813-I1Open ↗
▸Environmental & Asbestos3
▸DOB NOWDEP ACP-5: Asbestos Assessment Report3
08/25/2026Q00743501-S1Open ↗
08/25/2026Q00743501-I1Open ↗
08/13/2026Q00742813-I1Open ↗