← Back
One story retail building
63-79 SAUNDERS STREET
QUEENS · Rego Park · BIN 4072131
💬 Discuss this project
1962Year Built
1Stories
K1Building Class
C4-2Zoning
4,000 sfGross Floor Area
4Units
0 Open Violations
One story retail building · Owner of record: REGO IMPERIAL LLC · 5,000 sf lot · 0.8 FAR built · Flood zone X
Locations of Work
ArchitectureStructuralMechanicalPlumbing
Floor 14p · 1 filing · 20 docs
Cellar2p · 1 filing · 20 docs
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
C O RESOLUTION REAL ESTATE2007/08/2026
KNICKERBOCKER LAUNDRY SERVICES103/22/2026
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
MADRIAGA ENGINEERING P.C.607/02/2025
ALLEN SHINFELD, P.E. PLLC108/18/2023
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
YOUN DESIGN CORP203/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
ART OF CONSTRUCTIONGeneral Contractor607/08/2026
KONARZEWSKI, TADEUSZElectrical203/21/2026
SAUBERMAN, ALVINElectrical203/21/2026
OPTIMUM ELECTL CONTNG LLCElectrical103/22/2026
HOUSE OF SIGNSGeneral Contractor107/08/2026
NEW ERA MECHANICAL SER INPlumbing107/08/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
J&R DESIGN AND INSPECTION6637507/02/2025
Building Lifecycle
All (56)Filed (7)Permit Issued (6)Signed Off (4)Violation (10)Inspection (6)Special Inspection (23)
08/19/2025
Signed off — Alteration
INTERIOR RENOVATION OF EXISTING COMMERCIAL LAUNDROMAT. WORK INCLUDES ERECT NEW INTERIOR PARTITIONS, DRYER VENT, HOT WATER HEATER VENT, AND A/C INSTALLATION AS PER PLANS FILED HEREWITH. NO CHANGE IN USE, EGRESS, OR OCCUPANCY.
Q08010371-I1
08/15/2025
Permit issued — General Construction
Q08010371-I1-MS
07/07/2025
Signed off — Alteration
INTERIOR RENOVATION OF EXISTING COMMERCIAL LAUNDROMAT. WORK INCLUDES ERECT NEW INTERIOR PARTITIONS, DRYER VENT, HOT WATER HEATER VENT, AND A/C INSTALLATION AS PER PLANS FILED HEREWITH. NO CHANGE IN USE, EGRESS, OR OCCUPANCY.
Q08010371-S2
07/02/2025
Filed — Alteration
INTERIOR RENOVATION OF EXISTING COMMERCIAL LAUNDROMAT. WORK INCLUDES ERECT NEW INTERIOR PARTITIONS, DRYER VENT, HOT WATER HEATER VENT, AND A/C INSTALLATION AS PER PLANS FILED HEREWITH. NO CHANGE IN USE, EGRESS, OR OCCUPANCY.
Q08010371-P4
06/23/2025
Filed — Alteration
INTERIOR RENOVATION OF EXISTING COMMERCIAL LAUNDROMAT. WORK INCLUDES ERECT NEW INTERIOR PARTITIONS, DRYER VENT, HOT WATER HEATER VENT, AND A/C INSTALLATION AS PER PLANS FILED HEREWITH. NO CHANGE IN USE, EGRESS, OR OCCUPANCY.
Q08010371-P3
06/18/2025
Special inspection requirement — Maintenance information
Robert Truskosky
06/18/2025
Special inspection requirement — Final
Jonar Madriaga
06/18/2025
Special inspection requirement — Fire-Resistance Rated Construction
Robert Truskosky
06/18/2025
Special inspection requirement — Fenestration and door U-factor and product ratings
Robert Truskosky
06/18/2025
Special inspection requirement — HVAC-R and service water heating equipment
Robert Truskosky
06/18/2025
Special inspection requirement — Fenestration areas
Robert Truskosky
06/18/2025
Special inspection requirement — Air barrier - visual inspection
Robert Truskosky
06/18/2025
Special inspection requirement — HVAC-R and service water heating system controls
Robert Truskosky
06/18/2025
Special inspection requirement — Interior lighting power
Robert Truskosky
06/18/2025
Special inspection requirement — Fenestration air leakage
Robert Truskosky
06/18/2025
Special inspection requirement — Lighting controls
Robert Truskosky
06/18/2025
Special inspection requirement — Mechanical Systems
Robert Truskosky
06/18/2025
Special inspection requirement — Energy Code Compliance Inspections
Robert Truskosky
06/03/2025
Signed off — Alteration
INTERIOR RENOVATION OF EXISTING COMMERCIAL LAUNDROMAT. WORK INCLUDES ERECT NEW INTERIOR PARTITIONS, DRYER VENT, HOT WATER HEATER VENT, AND A/C INSTALLATION AS PER PLANS FILED HEREWITH. NO CHANGE IN USE, EGRESS, OR OCCUPANCY.
Q08010371-S1
10/10/2023
Signed off — Alteration
INSTALLATION OF NEW BUSINESS ACCESSORY AWNING AT OSP AS PER PLAN. NO CHANGE IN USE, OCCUPANCY OR EGRESS.
Q00921678-I1
09/13/2023
Inspection — Pass-Final General Construction Non-Directive 14
Pass
View inspection ↗
08/28/2023
Permit issued — General Construction
Q00921678-I1-GC
08/18/2023
Filed — Alteration
INSTALLATION OF NEW BUSINESS ACCESSORY AWNING AT OSP AS PER PLAN. NO CHANGE IN USE, OCCUPANCY OR EGRESS.
Q00921678-I1
05/15/2023
Inspection — Certified Gas-Gas-Piping-Roughing
Certified
View inspection ↗
04/28/2023
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Roughing
Certified
View inspection ↗
04/28/2023
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Underground
Certified
View inspection ↗
04/24/2023
Inspection — Certified Sprinkler (PL)-Sprinkler-Hydro
Certified
View inspection ↗
04/24/2023
Inspection — Certified Sprinkler (PL) - SP - Roughing
Certified
View inspection ↗
11/29/2022
Permit issued — General Construction
Q08010371-I1-GC
11/03/2022
Permit issued — Construction Fence
Q08010371-S2-FN
10/28/2022
Permit issued — Plumbing
Q08010371-S1-PL
10/25/2022
Special inspection requirement — Energy Code Compliance Inspections
Robert Truskosky
10/25/2022
Special inspection requirement — HVAC-R and service water heating system controls
Robert Truskosky
10/25/2022
Special inspection requirement — HVAC-R and service water piping design and insulation
Robert Truskosky
10/25/2022
Special inspection requirement — HVAC-R and service water heating equipment
Robert Truskosky
10/25/2022
Special inspection requirement — Fire-Resistant Penetrations and Joints
Robert Truskosky
10/24/2022
Filed — Alteration
INTERIOR RENOVATION OF EXISTING COMMERCIAL LAUNDROMAT. WORK INCLUDES ERECT NEW INTERIOR PARTITIONS, DRYER VENT, HOT WATER HEATER VENT, AND A/C INSTALLATION AS PER PLANS FILED HEREWITH. NO CHANGE IN USE, EGRESS, OR OCCUPANCY.
Q08010371-P1
10/24/2022
Special inspection requirement — Energy Code Compliance Inspections
Robert Truskosky
10/24/2022
Special inspection requirement — HVAC-R and service water heating equipment
Robert Truskosky
10/24/2022
Special inspection requirement — HVAC-R and service water heating system controls
Robert Truskosky
10/24/2022
Special inspection requirement — HVAC-R and service water piping design and insulation
Robert Truskosky
10/24/2022
Special inspection requirement — Fire-Resistant Penetrations and Joints
Robert Truskosky
10/20/2022
Filed — Alteration
INTERIOR RENOVATION OF EXISTING COMMERCIAL LAUNDROMAT. WORK INCLUDES ERECT NEW INTERIOR PARTITIONS, DRYER VENT, HOT WATER HEATER VENT, AND A/C INSTALLATION AS PER PLANS FILED HEREWITH. NO CHANGE IN USE, EGRESS, OR OCCUPANCY.
Q08010371-S2
10/20/2022
Filed — Alteration
INTERIOR RENOVATION OF EXISTING COMMERCIAL LAUNDROMAT. WORK INCLUDES ERECT NEW INTERIOR PARTITIONS, DRYER VENT, HOT WATER HEATER VENT, AND A/C INSTALLATION AS PER PLANS FILED HEREWITH. NO CHANGE IN USE, EGRESS, OR OCCUPANCY.
Q08010371-S1
10/11/2022
Permit issued — Mechanical Systems
Q08010371-I1-GC
10/04/2022
Filed — Alteration
INTERIOR RENOVATION OF EXISTING COMMERCIAL LAUNDROMAT. WORK INCLUDES ERECT NEW INTERIOR PARTITIONS, DRYER VENT, HOT WATER HEATER VENT, AND A/C INSTALLATION AS PER PLANS FILED HEREWITH. NO CHANGE IN USE, EGRESS, OR OCCUPANCY.
Q08010371-I1
03/03/2015
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
04/23/2010
Violation issued (ECB, closed)
Boilers
03/25/2010
Violation issued (ECB, closed)
Unknown
09/02/2009
Violation issued (ECB, closed)
Construction
02/01/2008
Violation issued (ECB, closed)
Construction
02/01/2008
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
05/27/2005
Violation issued (ECB, closed)
Boilers
09/23/1997
Violation issued (ECB, closed)
Boilers
07/08/1992
Violation issued (ECB, closed)
Boilers
06/09/1992
Violation issued (DOB, closed)
VP*-VIOLATION UNSERVED ECB- DISMISSED
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWGeneral ConstructionSigned-offART OF CONSTRUCTION08/15/2025
DOB NOWGeneral ConstructionSigned-offHOUSE OF SIGNS08/28/2023
DOB NOWGeneral ConstructionSigned-offART OF CONSTRUCTION11/29/2022
DOB NOWConstruction FenceSigned-offART OF CONSTRUCTION11/03/2022
DOB NOWPlumbingSigned-offNEW ERA MECHANICAL SER IN10/28/2022
DOB NOWMechanical SystemsSigned-offART OF CONSTRUCTION10/11/2022
BISOTISSUEDS & M PLUMBING AND HEATING04/28/2006
BISPLISSUEDAMERICAN NATIONAL PLUMBING AND H04/28/2006
BISBLISSUEDDUAL FUEL PLUMBING & HEATING11/06/1998
1 project · most recent 02/28/2023
General Wiring
FiledStatusContractorScope
02/28/2023Permit IssuedOPTIMUM ELECTL CONTNG LLCGeneral Wiring
▾Field Inspections (DOB CAP) — 6
DateTypeResultReport
09/13/2023Pass-Final General Construction Non-Directive 14PassView ↗
05/15/2023Certified Gas-Gas-Piping-RoughingCertifiedView ↗
04/28/2023Certified Water and Sanitary-WS-Sanitary Piping-RoughingCertifiedView ↗
04/28/2023Certified Water and Sanitary-WS-Sanitary Piping-UndergroundCertifiedView ↗
04/24/2023Certified Sprinkler (PL)-Sprinkler-HydroCertifiedView ↗
04/24/2023Certified Sprinkler (PL) - SP - RoughingCertifiedView ↗
▾Special Inspection Requirements (DOB NOW) — 23
DateRequirementInspectorRole
06/18/2025Maintenance informationRobert Truskoskyenergy_progress
06/18/2025FinalJonar Madriagaprogress
06/18/2025Fire-Resistance Rated ConstructionRobert Truskoskyprogress
06/18/2025Fenestration and door U-factor and product ratingsRobert Truskoskyenergy_progress
06/18/2025HVAC-R and service water heating equipmentRobert Truskoskyenergy_progress
06/18/2025Fenestration areasRobert Truskoskyenergy_progress
06/18/2025Air barrier - visual inspectionRobert Truskoskyenergy_progress
06/18/2025HVAC-R and service water heating system controlsRobert Truskoskyenergy_progress
06/18/2025Interior lighting powerRobert Truskoskyenergy_progress
06/18/2025Fenestration air leakageRobert Truskoskyenergy_progress
06/18/2025Lighting controlsRobert Truskoskyenergy_progress
06/18/2025Mechanical SystemsRobert Truskoskyspecial
06/18/2025Energy Code Compliance InspectionsRobert Truskoskyprogress
10/25/2022Energy Code Compliance InspectionsRobert Truskoskyprogress
10/25/2022HVAC-R and service water heating system controlsRobert Truskoskyenergy_progress
10/25/2022HVAC-R and service water piping design and insulationRobert Truskoskyenergy_progress
10/25/2022HVAC-R and service water heating equipmentRobert Truskoskyenergy_progress
10/25/2022Fire-Resistant Penetrations and JointsRobert Truskoskyspecial
10/24/2022Energy Code Compliance InspectionsRobert Truskoskyprogress
10/24/2022HVAC-R and service water heating equipmentRobert Truskoskyenergy_progress
10/24/2022HVAC-R and service water heating system controlsRobert Truskoskyenergy_progress
10/24/2022HVAC-R and service water piping design and insulationRobert Truskoskyenergy_progress
10/24/2022Fire-Resistant Penetrations and JointsRobert Truskoskyspecial
▾Documents — 42 on file (BIS + DOB NOW)
▸Plans & Drawings7
▸DOB NOWPlans/Sketch7
08/25/2026Q08010371-P4Request digital key ↗
08/25/2026Q08010371-P3Request digital key ↗
08/25/2026Q08010371-P1Request digital key ↗
Showing 3 of 7 on file for this type
▸Seals & Professional Certifications30
▸DOB NOWProgress Inspector Seal & Signature20
09/23/2026Q08010371-P3Open ↗
09/23/2026Q08010371-P3Open ↗
09/23/2026Q08010371-P3Open ↗
Showing 3 of 20 on file for this type
▸DOB NOWDPL-1: Design Professional Seal & Signature7
08/25/2026Q08010371-P4Open ↗
08/25/2026Q08010371-P3Open ↗
08/25/2026Q08010371-P1Open ↗
Showing 3 of 7 on file for this type
▸DOB NOWSpecial Inspector Seal & Signature3
09/23/2026Q08010371-P3Open ↗
08/28/2026Q08010371-P1Open ↗
08/23/2026Q08010371-S1Open ↗
▸Environmental & Asbestos5
▸DOB NOWDEP ACP-5: Asbestos Assessment Report5
08/25/2026Q08010371-I1Open ↗
08/25/2026Q08010371-P4Open ↗
08/25/2026Q08010371-P3Open ↗
Showing 3 of 5 on file for this type