← Back
BuildNYC
Two family brick
63-87 FITCHETT STREET
QUEENS · Rego Park · BIN 4073456
💬 Discuss this project
1930Year Built
2.5Stories
B1Building Class
R3-1Zoning
2,724 sfGross Floor Area
2Units
0 Active Violations
Two family brick · 8,655 sf lot · 0.31 FAR built · Flood zone X
Locations of Work
ArchitecturePlumbing
Names shown beside floors are taken automatically from the text of filed documents and may be incomplete or wrong.
Floor 210p · 1 filing · 20 docs
Floor 19p · 1 filing · 20 docs
Cellar10p · 1 filing · 20 docs
▾Sales History (ACRIS)
DatePriceUnitSeller → Buyer$/sf
03/21/2025$1.5M—Private party → Private party$551/sf building
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
Agt Architecture608/29/2025
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
Indesign Studio1203/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
Home Style ImprovementsGeneral Contractor303/21/2026
XH&RC Plumbing and HeatingPlumbing107/08/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
Yan Gao6619608/29/2025
Building Lifecycle
10/29/2025
Signed off — Alteration
INTERIOR RENOVATION OF EXISTING 2-FAMILY BUILDING AS PER PLAN FILED HEREWITH. NO CHANGE IN USE, EGRESS OR OCCUPANCY.
Q01207257-S1
09/16/2025
Signed off — Alteration
INTERIOR RENOVATION OF EXISTING 2-FAMILY BUILDING AS PER PLAN FILED HEREWITH. NO CHANGE IN USE, EGRESS OR OCCUPANCY.
Q01207257-I1
09/15/2025
Inspection — Pass-Final General Construction Non-Directive 14
Pass
View inspection ↗
09/02/2025
Special inspection requirement — Fire-Resistant Penetrations and Joints
YAN GAO
09/02/2025
Special inspection requirement — Fire-Resistance Rated Construction
GE TANG
34 history events on file for this building. Sign in free to see the full history. Sign in · Create account
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWPlumbingSigned-offXH&RC Plumbing and Heating05/06/2025
DOB NOWGeneral ConstructionSigned-offHome Style Improvements04/18/2025
1 project · most recent 07/18/2025
General Wiring
FiledStatusContractorScope
07/18/2025CompleteNelson & Tom Maintenance Inc DBGeneral Wiring
▾Field Inspections (DOB CAP) — 5
DateTypeResultReport
09/15/2025Pass-Final General Construction Non-Directive 14PassView ↗
06/05/2025Certified Gas-Gas-Piping-RoughingCertifiedView ↗
06/05/2025Certified Storm Drainage-ST-Piping-UndergroundCertifiedView ↗
06/05/2025Certified Water and Sanitary-WS-Sanitary Piping-RoughingCertifiedView ↗
06/03/2025Certified Remove/Cap - work done in accordance with codeCertifiedView ↗
▾Special Inspection Requirements (DOB NOW) — 20
DateRequirementInspectorRole
09/02/2025Fire-Resistant Penetrations and JointsYAN GAOspecial
09/02/2025Fire-Resistance Rated ConstructionGE TANGprogress
09/02/2025Energy Code Compliance InspectionsGE TANGprogress
09/02/2025Interior lighting powerGE TANGenergy_progress
09/02/2025Fenestration air leakageGE TANGenergy_progress
09/02/2025Fire-Resistant Penetrations and JointsYAN GAOspecial
09/02/2025Energy Code Compliance InspectionsGE TANGprogress
09/02/2025HVAC-R and service water heating equipmentGE TANGenergy_progress
09/02/2025HVAC-R and service water piping design and insulationGE TANGenergy_progress
09/02/2025HVAC-R and service water heating system controlsGE TANGenergy_progress
08/29/2025Fire-Resistant Penetrations and JointsYAN GAOspecial
08/29/2025Energy Code Compliance InspectionsGE TANGprogress
08/29/2025Fire-Resistance Rated ConstructionGE TANGprogress
08/29/2025Interior lighting powerGE TANGenergy_progress
08/29/2025Fenestration air leakageGE TANGenergy_progress
05/08/2025Fire-Resistant Penetrations and JointsYAN GAOspecial
05/08/2025Energy Code Compliance InspectionsGE TANGprogress
05/08/2025Fire-Resistance Rated ConstructionGE TANGprogress
05/08/2025Fenestration air leakageGE TANGenergy_progress
05/08/2025Interior lighting powerGE TANGenergy_progress
23 filed documents on file for this building. Sign in free to see the full history. Sign in · Create account