← Back
BuildNYC
Nursing home
630 EAST 104TH STREET
BROOKLYN · Canarsie · BIN 3229467
💬 Discuss this project
1975Year Built
7Stories
I6Building Class
R5Zoning
123,140 sfGross Floor Area
1Units
LL97 Covered0 Active ViolationsFISP: SAFEFDNY Report ↗
Nursing home · Owner of record: River Manor Acquisition I, LLC, A New YO RK · 47,500 sf lot · 2.59 FAR built · Flood zone X500
Locations of Work
ArchitectureStructuralMechanicalPlumbingFire Protection
Names shown beside floors are taken automatically from the text of filed documents and may be incomplete or wrong.
RoofAtrium Center for Rehabilitation & Nursing3p · 3 filings · 20 docs
BulkheadElevator extension and roof machine room2p · 1 filing · 12 docs
Floor 8Atrium Center for Rehabilitation & Nursing48p · 5 filings · 20 docs
Floor 7
Floor 6
Floor 5
Floor 4
Floor 3
Floor 2
Floor 1
Site & exteriorFacade repairs6p · 2 filings · 8 docs
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
River Manor Corp Dba River Mano903/21/2026
River Manor Acquisition I, LLC, A New YO RK103/22/2026
▾Sales History (ACRIS)
DatePriceUnitSeller → Buyer$/sf
04/09/2014$3.4M—— → —$27/sf building
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
Elevated Engineering NYC208/08/2025
SGM Engineering906/10/2024
Ashraf101/19/2024
Scope Engineering Consultants112/29/2023
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
Danico Services203/21/2026
Advanced Builders Services203/21/2026
Municipal Building Consultants103/21/2026
Eretz Builders Assistance1603/21/2026
AE Design Solution203/21/2026
BAC Developers Group103/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
Metropolitan ConstructionGeneral Contractor507/08/2026
Triple C InteriorsGeneral Contractor407/08/2026
WNW & Sons Plumbing & HeatingPlumbing307/08/2026
Berkowits RealtyGeneral Contractor207/08/2026
Safe-Sheild EnterpriseScaffold107/08/2026
Prime Piping & HeatingFire Protection107/08/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
HRF Services5616308/08/2025
Leo Y Lee Associates2481102/14/2024
SGM Engineering2366502/08/2024
Scope Engineering Consulting7894112/29/2023
Shahrish Shuvo Engineering8524209/08/2022
Building Lifecycle
All (162)Filed (14)Permit Issued (16)Signed Off (8)Facade (FISP) (9)Violation (60)Inspection (7)Objection (18)Special Inspection (30)
08/27/2026
Signed off — Alteration
B00783334-I1
06/17/2026
Signed off — Alteration
PLUMBING WORK ASSOCIATED WITH INTERIOR RENOVATION OF OT/PT SPACE ON 8TH FLOOR IN CONJUNCTION WITH ALT-1 APPLICATION #320891095
B00783338-I1
05/07/2026
Signed off — Alteration
Installation of suspended scaffold for facade work or inspection
B01004491-I1
05/06/2026
Permit issued — Suspended Scaffold
B01004491-I1-SC
05/05/2026
Signed off — Alteration
EXTENSION OF ELEVATOR TO 8TH FLOOR, AND ADDING ELEVATOR MACHINE ROOM ON ROOF IN CONJUNCTION WITH ALT-1 APPLICATION #320891095
B00883752-I1
04/30/2026
Signed off — Alteration
B01064076-I1
03/13/2026
Permit issued — Structural
B00883752-I1-ST
11/14/2025
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
09/03/2025
Permit issued — Structural
B00883752-I1-ST
08/25/2025
Special inspection requirement — Structural Stability – Alterations of existing buildings
FAHAD FATEH
08/25/2025
Special inspection requirement — Final
FAHAD FATEH
08/25/2025
Special inspection requirement — Structural Steel - High Strength Bolting
FAHAD FATEH
08/25/2025
Special inspection requirement — Post-installed Anchors
FAHAD FATEH
08/25/2025
Special inspection requirement — Structural Steel - Welding
FAHAD FATEH
08/25/2025
Special inspection requirement — Structural Steel - Details
FAHAD FATEH
08/08/2025
Filed — Alteration
EXTENSION OF ELEVATOR TO 8TH FLOOR, AND ADDING ELEVATOR MACHINE ROOM ON ROOF IN CONJUNCTION WITH ALT-1 APPLICATION #320891095
B00883752-P1
08/06/2025
Special inspection requirement — Post-installed Anchors
FAHAD FATEH
08/06/2025
Special inspection requirement — Final
FAHAD FATEH
08/06/2025
Special inspection requirement — Structural Steel - Welding
FAHAD FATEH
08/06/2025
Special inspection requirement — Structural Steel - High Strength Bolting
FAHAD FATEH
08/06/2025
Special inspection requirement — Structural Steel - Details
FAHAD FATEH
08/06/2025
Special inspection requirement — Structural Stability – Alterations of existing buildings
FAHAD FATEH
04/02/2025
Violation issued (FDNY_ORDER, closed)
11/25/2024
Inspection — Certified Water and Sanitary-WS-Fixtures-Finish
Certified
View inspection ↗
11/21/2024
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Roughing
Certified
View inspection ↗
11/15/2024
Inspection — Certified Sprinkler-SP-Fixtures-Finish
Certified
View inspection ↗
11/13/2024
Permit issued — Plumbing
B00783338-I1-PL
11/13/2024
Inspection — Certified Remove/Cap - work done in accordance with code
Certified
View inspection ↗
11/13/2024
Inspection — Certified Sprinkler-SP-Piping Dry/Wet-Hydrostatic Test
Certified
View inspection ↗
09/12/2024
Signed off — Alteration
HEAVY DUTY SWS FOR EXTERIOR FACADE REPAIR UNDER JOB # B00983055-I1. NO CHANGE IN USE, EGRESS OR OCCUPANCY UNDER THIS APPLICATION. SWS SHALL COMPLY WITH CH 33 OF THE 2022 BUIILDING CODE.
B00991648-I1
09/12/2024
Cycle 9 facade report signed — SAFE
09/10/2024
Cycle 9 facade report submitted
08/30/2024
Signed off — Alteration
FACADE REPAIRS AS PER PLANS FILED HEREWITH. NO CHANGE TO USE, EGRESS, OR OCCUPANCY,
B00983055-I1
08/29/2024
Cycle 9 facade inspection completed
06/24/2024
Permit issued — Mechanical Systems
B00783334-I1-MS
06/18/2024
Permit issued — Sprinklers
B01064076-I1-EW-SP
06/10/2024
Filed — Alteration
B01064076-I1
06/10/2024
Permit issued — General Construction
B00983055-I1-GC
06/10/2024
Permit issued — Suspended Scaffold
B01004491-I1-SC
03/15/2024
Permit issued — General Construction
B00983055-I1-GC
03/08/2024
Permit issued — Suspended Scaffold
B01004491-I1-SC
03/01/2024
Signed off — Alteration
MECHANICAL WORK ASSOCIATED WITH REMOVAL OF EXISTING BOILERS AND INSTALLATION OF NEW BOILER SYSTEM FOR DOMESTIC WATER HEATING IN CONJUNCTION WITH ALT-1 #320891095
B00754058-I1
02/22/2024
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
02/21/2024
Permit issued — Suspended Scaffold
B01004491-I1-SC
02/20/2024
Inspection — Pass-Final Boiler Equipment Inspection
Pass
View inspection ↗
02/14/2024
Filed — Alteration
Installation of suspended scaffold for facade work or inspection
B01004491-I1
02/14/2024
Special inspection requirement — HVAC-R and service water heating equipment
steven Giammona
02/14/2024
Special inspection requirement — Fire-Resistant Penetrations and Joints
steven Giammona
02/14/2024
Special inspection requirement — HVAC-R and service water heating system controls
steven Giammona
02/13/2024
Permit issued — General Construction
B00983055-I1-GC
02/12/2024
Special inspection requirement — Post-installed Anchors
Leo Lee
02/12/2024
Special inspection requirement — Alternative Materials - OTCR Buildings Bulletin Number
Leo Lee
02/08/2024
Filed — Alteration
MECHANICAL WORK ASSOCIATED WITH REMOVAL OF EXISTING BOILERS AND INSTALLATION OF NEW BOILER SYSTEM FOR DOMESTIC WATER HEATING IN CONJUNCTION WITH ALT-1 #320891095
B00754058-P4
02/02/2024
Permit issued — Structural
B00883752-I1-ST
02/02/2024
Special inspection requirement — HVAC-R and service water heating equipment
steven Giammona
02/02/2024
Special inspection requirement — HVAC-R and service water heating system controls
steven Giammona
02/02/2024
Special inspection requirement — Fire-Resistant Penetrations and Joints
steven Giammona
01/31/2024
Objection resolved — Addressed
01/31/2024
Objection resolved — Addressed
01/22/2024
Permit issued — Sidewalk Shed
B00991648-I1-SH
Latest 60 of 162 events.
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWSuspended ScaffoldSigned-offMetropolitan Construction05/06/2026
DOB NOWStructuralSigned-offBerkowits Realty03/13/2026
DOB NOWStructuralSigned-offBerkowits Realty09/03/2025
DOB NOWPlumbingSigned-offWNW & Sons Plumbing & Heating11/13/2024
DOB NOWMechanical SystemsSigned-offTriple C Interiors06/24/2024
DOB NOWSprinklersSigned-offAmb Mechanical06/18/2024
DOB NOWGeneral ConstructionSigned-offMetropolitan Construction06/10/2024
DOB NOWSuspended ScaffoldSigned-offMetropolitan Construction06/10/2024
DOB NOWGeneral ConstructionSigned-offMetropolitan Construction03/15/2024
DOB NOWSuspended ScaffoldSigned-offMetropolitan Construction03/08/2024
DOB NOWSuspended ScaffoldSigned-offMetropolitan Construction02/21/2024
DOB NOWGeneral ConstructionSigned-offMetropolitan Construction02/13/2024
DOB NOWStructuralSigned-offTriple C Interiors02/02/2024
DOB NOWSidewalk ShedSigned-offSafe-Sheild Enterprise01/22/2024
DOB NOWBoiler EquipmentSigned-offWNW & Sons Plumbing & Heating01/10/2024
DOB NOWBoiler EquipmentSigned-offWNW & Sons Plumbing & Heating11/10/2022
BIS—ISSUEDBerkowits Realty09/30/2024
BISPLISSUEDWNW & Sons Plumbing & Heating07/15/2024
BIS—ISSUEDTriple C Interiors01/19/2024
BIS—ISSUEDTriple C Interiors06/01/2022
BISFPISSUEDWilliam Hird & Co03/02/2017
BISPLISSUEDHeadquarters Mechanical07/09/2015
BISMHISSUEDPower Air Cond06/04/2015
BISSPISSUEDAJC Sprinkler02/10/2015
BIS—ISSUEDIcon Interior Design08/05/2014
BISOTISSUEDAvh Construction Builders05/07/2013
BISSPISSUEDAJC Sprinkler05/06/2013
BISEQISSUEDSkyline Scaffolding Group10/23/2012
BISPLISSUEDCity Testing & Plumbing I12/07/2011
BISOTISSUEDTownhouse Builders11/14/2011
BISOTISSUEDMcAlpine Construction Co07/01/2009
BISMHISSUEDG. Fazio Construction Co02/08/2006
BISOTISSUEDG. Fazio Construction Co02/07/2006
BISPLISSUEDCN Plumbing02/02/2006
BISMHISSUEDAbar Central Service05/16/2005
BISOTISSUEDG. Fazio Construction Co12/21/2004
BISOTISSUEDG. Fazio Construction Co07/28/2004
BISFPISSUEDWilliam Hird & Co11/07/2003
BISPLISSUEDVip Sewer Cleaning Seervice01/10/2003
BISMHISSUEDRiver Manor Care Center07/11/2001
+ 2 more permits on file
1 project · most recent 05/30/2023
Gas Water/Sanitary
FiledStatusContractorScope
05/30/2023Signed-offWNW & Sons Plumbing & HeatingGas, Water/Sanitary
9 projects · most recent 06/17/2026
General Wiring
FiledStatusContractorScope
06/17/2026Permit IssuedDenali Electric—
06/16/2026CompleteFried Electric CoGeneral Wiring
05/11/2026CompleteDenali Electric—
04/27/2026CompleteFried Electric CoGeneral Wiring
02/15/2024Permit IssuedHivolts ElectricalGeneral Wiring
01/26/2024CompleteK.N.C. Electric—
10/28/2022Permit IssuedDenali Electric—
10/21/2022Permit IssuedDenali Electric—
05/04/2018CompleteMartin DorkinGeneral Wiring
1 project · most recent 08/08/2025
Steel
FiledStatusContractorScope
08/08/2025Signed-offBerkowits RealtySteel
▾Field Inspections (DOB CAP) — 7
DateTypeResultReport
11/25/2024Certified Water and Sanitary-WS-Fixtures-FinishCertifiedView ↗
11/21/2024Certified Water and Sanitary-WS-Sanitary Piping-RoughingCertifiedView ↗
11/15/2024Certified Sprinkler-SP-Fixtures-FinishCertifiedView ↗
11/13/2024Certified Remove/Cap - work done in accordance with codeCertifiedView ↗
11/13/2024Certified Sprinkler-SP-Piping Dry/Wet-Hydrostatic TestCertifiedView ↗
02/20/2024Pass-Final Boiler Equipment InspectionPassView ↗
11/14/2023Fail-Final Boiler Equipment InspectionFailView ↗
▾Special Inspection Requirements (DOB NOW) — 33
DateRequirementInspectorRole
08/25/2025Structural Stability – Alterations of existing buildingsFAHAD FATEHspecial
08/25/2025FinalFAHAD FATEHprogress
08/25/2025Structural Steel - High Strength BoltingFAHAD FATEHspecial
08/25/2025Post-installed AnchorsFAHAD FATEHspecial
08/25/2025Structural Steel - WeldingFAHAD FATEHspecial
08/25/2025Structural Steel - DetailsFAHAD FATEHspecial
08/06/2025Post-installed AnchorsFAHAD FATEHspecial
08/06/2025FinalFAHAD FATEHprogress
08/06/2025Structural Steel - WeldingFAHAD FATEHspecial
08/06/2025Structural Steel - High Strength BoltingFAHAD FATEHspecial
08/06/2025Structural Steel - DetailsFAHAD FATEHspecial
08/06/2025Structural Stability – Alterations of existing buildingsFAHAD FATEHspecial
02/14/2024HVAC-R and service water heating equipmentsteven Giammonaenergy_progress
02/14/2024Fire-Resistant Penetrations and Jointssteven Giammonaspecial
02/14/2024HVAC-R and service water heating system controlssteven Giammonaenergy_progress
02/12/2024Post-installed AnchorsLeo Leespecial
02/12/2024Alternative Materials - OTCR Buildings Bulletin NumberLeo Leespecial
02/02/2024HVAC-R and service water heating equipmentsteven Giammonaenergy_progress
02/02/2024HVAC-R and service water heating system controlssteven Giammonaenergy_progress
02/02/2024Fire-Resistant Penetrations and Jointssteven Giammonaspecial
01/11/2024Structural Stability – Alterations of existing buildingsPaul Henryspecial
12/28/2023FinalPaul Henryprogress
12/28/2023MasonryPaul Henryspecial
12/13/2023HVAC-R and service water heating equipmentsteven Giammonaenergy_progress
12/13/2023Fire-Resistant Penetrations and Jointssteven Giammonaspecial
Latest 25 of 33.
▾Tenants in the building
TenantSpaceFloorsRenovation projects
Atrium Center for Rehabilitation & NursingMedical / HealthcareFloor 8
Project B00783334 Alteration · LOC Issued · 09/08/2022
Project B00783338 Alteration · LOC Issued · 09/08/2022
Project B00754058 Alteration · LOC Issued · 06/15/2022
Project B01064076 Alteration · LOC Issued · 06/10/2024
Names are taken automatically from the text of each project’s filed documents (title blocks and cover sheets) and screened to exclude owners, landlords and designers. They may be incomplete or wrong; check the filing.
▾Documents — 296 on file (BIS + DOB NOW)
▸Plans & Drawings14
▸DOB NOWPlans/Sketch14
08/28/2026B00783338-P1Request digital key ↗
08/28/2026B00783334-I1Request digital key ↗
08/26/2026B00983055-I1Request digital key ↗
Showing 3 of 14 on file for this type
▸Applications & Permits52
▸BISPLAN / WORK APPROVAL APPLICATION33
12/26/2024320891095Open ↗
12/02/2024320891095Open ↗
09/14/2022320891095Open ↗
Showing 3 of 33 on file for this type
▸BISWORK PERMIT APPLICATION17
10/01/2024320891095Open ↗
07/15/2024321172173Open ↗
01/25/2024320891095Open ↗
Showing 3 of 17 on file for this type
▸BISCERTIFICATE OF OCCUPANCY: APPLICATION1
11/14/2024320891095Open ↗
▸BISPLACE OF ASSEMBLY1
On file, but not among the 200 most recently loaded documents for this source.
Showing 0 of 1 on file for this type
▸Seals & Professional Certifications74
▸BISTECHNICAL REPORT: RESPONSIBILITY/CERTIFICATION29
10/13/2017321661689Open ↗
10/19/2016321455607Open ↗
01/27/2016321140494Open ↗
Showing 3 of 29 on file for this type
▸DOB NOWProgress Inspector Seal & Signature14
09/23/2026B00754058-I1Open ↗
09/23/2026B00754058-I1Open ↗
09/02/2026B00754058-P2Open ↗
Showing 3 of 14 on file for this type
▸DOB NOWDPL-1: Design Professional Seal & Signature13
08/28/2026B00783338-P1Open ↗
08/28/2026B00783338-I1Open ↗
08/26/2026B00983055-I1Open ↗
Showing 3 of 13 on file for this type
▸DOB NOWSpecial Inspector Seal & Signature12
09/23/2026B00754058-I1Open ↗
09/02/2026B00754058-P2Open ↗
09/01/2026B01004491-I1Open ↗
Showing 3 of 12 on file for this type
▸BISPROFESSIONAL CERTIFIED CHECKLIST3
06/05/2015321140494Open ↗
10/24/2012320541954Open ↗
Showing 2 of 3 on file for this type
▸BISPROFESSIONAL CERTIFICATION STATEMENT FORM2
10/24/2012320541954Open ↗
Showing 1 of 2 on file for this type
▸BISPROFESSIONAL CERTIFICATION STATEMENT1
06/05/2015321140494Open ↗
▸Trade Schedules & Equipment27
▸BISSELF-CERT PLUMBING NOTICE6
05/15/2015320531876Open ↗
06/09/2014320531876Open ↗
11/02/2013320531876Open ↗
Showing 3 of 6 on file for this type
▸BISSCHEDULE B - PLUMBING6
10/03/2014320964649Open ↗
07/12/2014320531876Open ↗
09/19/2013320531876Open ↗
Showing 3 of 6 on file for this type
▸BISSCHEDULE B - PLUMBING/SPRINKLER/STANDPIPE5
09/01/2015321172173Open ↗
09/01/2015321172164Open ↗
06/05/2015321140494Open ↗
Showing 3 of 5 on file for this type
▸BISEQUIPMENT USE APPLICATION/PERMIT4
01/27/2016321140494Open ↗
01/27/2016321140494Open ↗
06/05/2015321140494Open ↗
Showing 3 of 4 on file for this type
▸BISFA - FDNY APPROVAL : FD-FAA2
03/18/2019321388789Open ↗
03/03/2017321455607Open ↗
▸BISSCHEDULE C - HEATING & COMBUSTION EQUIPMENT2
On file, but not among the 200 most recently loaded documents for this source.
Showing 0 of 2 on file for this type
▸BISSPRINKLER INSP REPORT : FP-851
10/15/2013320531876Open ↗
▸BISEQUIPMENT USE PERMITS1
01/27/2016321140494Open ↗
▸Safety & Tenant Protection3
▸BISSTREET TREE CHECKLIST3
06/24/2014320891095Open ↗
08/01/2011320310686Open ↗
Showing 2 of 3 on file for this type
▸Environmental & Asbestos19
▸DOB NOWDEP ACP-5: Asbestos Assessment Report12
08/28/2026B00783338-P1Open ↗
08/26/2026B00983055-I1Open ↗
08/26/2026B00754058-P4Open ↗
Showing 3 of 12 on file for this type
▸BISASBESTOS: CERTIFICATION (DEP ACP5)4
10/19/2016321455607Open ↗
11/16/2013320893128Open ↗
08/07/2012320531894Open ↗
Showing 3 of 4 on file for this type
▸BISTHIS IS 'NOT AN ASBESTOS PROJECT'2
08/01/2011320310686Open ↗
Showing 1 of 2 on file for this type
▸BISASBESTOS EXEMPTION CERTIFICATION LETTER1
On file, but not among the 200 most recently loaded documents for this source.
Showing 0 of 1 on file for this type
▸Energy Compliance26
▸BISTECHNICAL REPORT: ENERGY CODE - RESPONSIBILITY6
12/10/2024320891095Open ↗
12/09/2024320891095Open ↗
11/25/2024320891095Open ↗
Showing 3 of 6 on file for this type
▸BISTECHNICAL REPORT: ENERGY CODE PROGRESS INSPS6
01/27/2016321140494Open ↗
09/01/2015321172155Open ↗
06/05/2015321140494Open ↗
Showing 3 of 6 on file for this type
▸DOB NOWPreliminary Commissioning Report Certification2
08/28/2026B00783334-I1Open ↗
08/13/2026B00754058-I1Open ↗
▸DOB NOWEN2: As Built Energy Analysis2
08/28/2026B00783334-I1Open ↗
08/13/2026B00754058-I1Open ↗
▸BISFENESTRATION AREAS1
12/05/2024320891095Open ↗
▸BISAS-BUILT ENERGY ANALYSIS1
01/27/2016321140494Open ↗
▸BISINTERIOR LIGHTING POWER1
12/05/2024320891095Open ↗
▸BISTECHNICAL REPORT: ENERGY1
08/01/2011320310686Open ↗
▸BISAIR SEALING AND INSULATION - VISUAL1
12/05/2024320891095Open ↗
▸BISINSULATION PLACEMENT & R VALUES1
12/05/2024320891095Open ↗
▸BISTR8: Energy Code Progress Inspections1
10/03/2014320964649Open ↗
▸BISENERGY CODE COMPLIANCE INSPECTIONS1
12/05/2024320891095Open ↗
▸BISFENESTRATION AIR LEAKAGE1
12/05/2024320891095Open ↗
▸BISFENESTRATION U-FACTOR & PRODUCT RATING1
12/05/2024320891095Open ↗
▸Inspections & Test Reports8
▸BISTECHNICAL REPORT: RESPONSIBILITY6
12/10/2024320891095Open ↗
12/09/2024320891095Open ↗
11/25/2024320891095Open ↗
Showing 3 of 6 on file for this type
▸BISFIRE-RESISTANT PENETRATIONS AND JOINTS (FIRESTOP)1
12/05/2024320891095Open ↗
▸BISFIRE-RESISTIVE RATED CONSTRUCTION1
12/05/2024320891095Open ↗
▸Approvals, Objections & Sign-offs24
▸BISADMINISTRATIVE OBJECTIONS11
09/18/2015321172155Open ↗
06/05/2015321140494Open ↗
10/03/2014320964649Open ↗
Showing 3 of 11 on file for this type
▸BISLETTERS - SUPPORTING DOCUMENTATION7
10/01/2024320891095Open ↗
05/01/2013320531876Open ↗
05/01/2013320531876Open ↗
Showing 3 of 7 on file for this type
▸BISCERTIFICATE OF OCCUPANCY/LOC: REQUEST3
01/27/2016321140494Open ↗
01/22/2016320531876Open ↗
07/03/2012320035216Open ↗
▸BISSCHEDULE A - OCCUPANCY / USE3
12/02/2024320891095Open ↗
06/24/2014320891095Open ↗
04/16/2014320891095Open ↗
▸Cost, Insurance & Ownership18
▸BISCOST AFFIDAVIT18
10/13/2017321661689Open ↗
10/19/2016321455607Open ↗
05/25/2016321388789Open ↗
Showing 3 of 18 on file for this type
▸Filing & Intake Forms28
▸BISEFILING COVER SHEET15
10/13/2017321661689Open ↗
10/19/2016321455607Open ↗
05/25/2016321388789Open ↗
Showing 3 of 15 on file for this type
▸BISADDITIONAL INFORMATION13
01/30/2025320891095Open ↗
01/30/2025320891095Open ↗
01/30/2025320891095Open ↗
Showing 3 of 13 on file for this type
▸Other Documents3
▸BISPLOT DIAGRAM1
06/24/2014320891095Open ↗
▸DOB NOWCalculations1
08/13/2026B01004491-I1Open ↗
▸DOB NOWManufacturer's Specifications1
08/13/2026B01004491-I1Open ↗