← Back
Convent
Angel Guardian Home
6301 12TH AVENUE · BIN 3345686
💬 Discuss this project
1902Year Built
3Stories
M4Building Class
R5BZoning
66,491 sfGross Floor Area
1Units
LL97 Covered2 Open Violations ▸FDNY Report ↗
Convent · Owner of record: 6301 12TH AVE LLC · 49,879 sf lot · 1.33 FAR built · Flood zone X
Locations of Work
ArchitectureStructuralMechanicalPlumbingFire ProtectionGeneral
Roof81p · 1 filing · 20 docs
Floor 41p · 1 filing · 14 docs
Floor 381p · 2 filings · 20 docs
Floor 286p · 2 filings · 20 docs
Floor 185p · 2 filings · 20 docs
Mezzanine81p · 1 filing · 20 docs
Cellar86p · 2 filings · 20 docs
Basement81p · 1 filing · 20 docs
1 job · most recent 08/03/2026
Heating and Air Conditioning Systems Refrigeration Systems Ventilation Systems
FiledStatusContractorScopeMake / Model / Capacity
08/03/2026Permit IssuedTOWNHOUSE BUILDERS INCHeating and Air Conditioning Systems, Refrigeration Systems, Ventilation Systems
Heat / Cool
Mitsubishi Electric MXZ-SM48NAMHZ2-U1 66,000 BTU · Heat Pump Outdoor ×44
MXZ-SM36NAMHZ2-U1 36,000 BTU · Heat Pump Outdoor ×24
PUHY-EP96TNU-A 96,000 BTU · Vrf Outdoor ×12
PURY-EP72TNU-A 72,000 BTU · Vrf Outdoor ×12
PUHY-EP144TNU-A1 144,000 BTU · Vrf Outdoor ×8
PURY-EP120TNU-A 120,000 BTU · Vrf Outdoor ×8
MUZ-GS24NA 22,400 BTU · Heat Pump Outdoor ×4
PURY-EP168TNU-A 168,000 BTU · Vrf Outdoor ×4
PURY-EP96TNU-A1 96,000 BTU · Vrf Outdoor ×4
Ventilation
Greenheck SP-B150 150 CFM · Exhaust Fan ×20
G-140HP-VG 1,150 CFM · Exhaust Fan ×12
G-097-A 200 CFM · Exhaust Fan ×8
SP-A110 100 CFM · Exhaust Fan ×8
SP-B80 50 CFM · Exhaust Fan ×8
SQ-97-VG 425 CFM · Exhaust Fan ×8
G-100HP-VG 650 CFM · Exhaust Fan ×4
G-160HP 1,365 CFM · Exhaust Fan ×4
G-200HP-VG 2,725 CFM · Exhaust Fan ×4
GB-160HP 1,600 CFM · Exhaust Fan ×4
SQ-80-VG 300 CFM · Exhaust Fan ×4
SQ-90-VG 375 CFM · Exhaust Fan ×4
Captiveaire A3-D.500-24D-MPU 5 tons · Makeup Air ×8
DU240HFA 5,550 CFM · Kitchen Exhaust ×8
Energywall HE10IN 700 CFM · Erv ×4
HE3XIN 2,250 CFM · Erv ×4
HE3XRT 2,250 CFM · Erv ×4
LE6XRT 2,935 CFM · Erv ×4
Refrigeration
Heatcraft BCH0015MCACZA0000 1 kW · Refrigeration Unit ×4
BCH0035LCACZA0200 1 kW · Refrigeration Unit ×4
1 job · most recent 08/03/2026
Sprinkler System
FiledStatusContractorScope
08/03/2026Signed-offSAFETY FIRE SPRINKLER CORSprinkler System
1 job · most recent 08/03/2026
Gas Storm Water/Sanitary
FiledStatusContractorScope
08/03/2026Signed-offCREATIVE PLUMBING INGas, Storm, Water/Sanitary
7 jobs · most recent 09/18/2025
General Wiring
FiledStatusContractorScope
09/18/2025CancelledPRIME ELECTRICAL CORP—
05/01/2025CompletePRIME ELECTRICAL CORPGeneral Wiring
05/16/2023CompleteVILLAGE ELECTL CONTRS INCGeneral Wiring
04/14/2021CompleteGREEN STAR ELECTL CONT IN1 meters, 1 new_meters
10/21/2020CompleteSTAR ELEC'L CONTRACTORS C—
10/21/2020CompleteSTAR ELEC'L CONTRACTORS C—
12/16/2019CompleteKWONG MING ELECTRIC INC1 meters, 1 new_meters
Building Lifecycle
All (155)Filed (21)Permit Issued (25)Signed Off (9)Violation (35)Inspection (13)Objection (22)Special Inspection (30)
09/01/2026
Signed off — Alteration CO
INSTALL NEW SPRINKLER/STANDPIPE AND PLUMBING SYSTEMS, FILED AS SUBSEQUENT FILING FOR ALTERATION CO, B00487186-I1 AS PER 2007 NFPA13-2007, NFPA14-2007, NFPA20-2007, 2014 BUILDING CODE AND 2014 PLUMBING CODE.
B00487186-I1
08/21/2026
Special inspection requirement — Fire-Resistance Rated Construction
MAURICIO ANDRADE
08/21/2026
Special inspection requirement — Fire-Resistant Penetrations and Joints
MAURICIO ANDRADE
08/21/2026
Special inspection requirement — Structural Stability – Alterations of existing buildings
MAURICIO ANDRADE
08/03/2026
Filed — Alteration CO
INSTALL NEW SPRINKLER/STANDPIPE AND PLUMBING SYSTEMS, FILED AS SUBSEQUENT FILING FOR ALTERATION CO, B00487186-I1 AS PER 2007 NFPA13-2007, NFPA14-2007, NFPA20-2007, 2014 BUILDING CODE AND 2014 PLUMBING CODE.
B00487186-P9
08/03/2026
Special inspection requirement — Structural Stability – Alterations of existing buildings
MAURICIO ANDRADE
08/03/2026
Special inspection requirement — Fire-Resistant Penetrations and Joints
MAURICIO ANDRADE
08/03/2026
Special inspection requirement — Fire-Resistance Rated Construction
MAURICIO ANDRADE
07/08/2026
Filed — Alteration CO
INSTALL NEW SPRINKLER/STANDPIPE AND PLUMBING SYSTEMS, FILED AS SUBSEQUENT FILING FOR ALTERATION CO, B00487186-I1 AS PER 2007 NFPA13-2007, NFPA14-2007, NFPA20-2007, 2014 BUILDING CODE AND 2014 PLUMBING CODE.
B00487186-P8
07/07/2026
Special inspection requirement — Fire-Resistance Rated Construction
MAURICIO ANDRADE
07/07/2026
Special inspection requirement — Fire-Resistant Penetrations and Joints
MAURICIO ANDRADE
07/07/2026
Special inspection requirement — Structural Stability – Alterations of existing buildings
MAURICIO ANDRADE
12/23/2025
Inspection — Pass-Final PL - Up to 3 Requested Floors
Pass
View inspection ↗
12/17/2025
Signed off — Alteration CO
INSTALL NEW SPRINKLER/STANDPIPE AND PLUMBING SYSTEMS, FILED AS SUBSEQUENT FILING FOR ALTERATION CO, B00487186-I1 AS PER 2007 NFPA13-2007, NFPA14-2007, NFPA20-2007, 2014 BUILDING CODE AND 2014 PLUMBING CODE.
B00487186-S3
07/29/2025
Permit issued — General Construction
B00487186-I1-GC
03/17/2025
Objection raised — Other
03/17/2025
Objection resolved — Addressed
03/17/2025
Objection resolved — Addressed
03/17/2025
Special inspection requirement — Public Assembly Emergency Lighting
MAURICIO ANDRADE
03/11/2025
Objection raised — Other
03/10/2025
Objection resolved — Addressed
03/05/2025
Objection raised — Other
03/04/2025
Filed — Alteration CO
INSTALL NEW SPRINKLER/STANDPIPE AND PLUMBING SYSTEMS, FILED AS SUBSEQUENT FILING FOR ALTERATION CO, B00487186-I1 AS PER 2007 NFPA13-2007, NFPA14-2007, NFPA20-2007, 2014 BUILDING CODE AND 2014 PLUMBING CODE.
B00487186-P7
03/03/2025
Special inspection requirement — Fire-Resistance Rated Construction
MAURICIO ANDRADE
03/03/2025
Special inspection requirement — Fire-Resistant Penetrations and Joints
MAURICIO ANDRADE
03/03/2025
Special inspection requirement — Structural Stability – Alterations of existing buildings
MAURICIO ANDRADE
02/28/2025
Filed — No Work
B01076539-P1
02/28/2025
Special inspection requirement — Public Assembly Emergency Lighting
MAURICIO ANDRADE
01/21/2025
Filed — Alteration CO
INSTALL NEW SPRINKLER/STANDPIPE AND PLUMBING SYSTEMS, FILED AS SUBSEQUENT FILING FOR ALTERATION CO, B00487186-I1 AS PER 2007 NFPA13-2007, NFPA14-2007, NFPA20-2007, 2014 BUILDING CODE AND 2014 PLUMBING CODE.
B00487186-P6
01/16/2025
Inspection — Pass-Final CND-Occupancy Inspection
Pass
View inspection ↗
12/26/2024
Signed off — Alteration CO
INSTALL NEW SPRINKLER/STANDPIPE AND PLUMBING SYSTEMS, FILED AS SUBSEQUENT FILING FOR ALTERATION CO, B00487186-I1 AS PER 2007 NFPA13-2007, NFPA14-2007, NFPA20-2007, 2014 BUILDING CODE AND 2014 PLUMBING CODE.
B00487186-S4
12/19/2024
Permit issued — Mechanical Systems
B00487186-S4-MS
12/09/2024
Inspection — Pass-Final CND-Occupancy Inspection
Pass
View inspection ↗
12/04/2024
Inspection — Certified Sprinkler-Dry Pipe Valve (SP)-Dry Pipe Valve Test
Certified
View inspection ↗
12/04/2024
Inspection — Certified Sprinkler-SP-Fixtures-Finish
Certified
View inspection ↗
12/04/2024
Inspection — Certified StandPipe-SD-Fixtures-Finish-SD
Certified
View inspection ↗
12/03/2024
Inspection — Pass-Final CND-Occupancy Inspection
Pass
View inspection ↗
11/29/2024
Permit issued — Plumbing
B00487186-S3-EW-SD
11/29/2024
Permit issued — Sprinklers
B00487186-S3-EW-SP
11/28/2024
Inspection — Certified Sprinkler (SP) - Booster Pump Test
Certified
View inspection ↗
11/28/2024
Inspection — Certified Sprinkler-SP-Piping Dry/Wet-Hydrostatic Test
Certified
View inspection ↗
11/28/2024
Inspection — Certified StandPipe-SD-Piping-Hydrostatic Test
Certified
View inspection ↗
11/14/2024
Special inspection requirement — Fire-Resistant Penetrations and Joints
MAURICIO ANDRADE
11/14/2024
Special inspection requirement — Sprinkler Systems
MAURICIO ANDRADE
11/14/2024
Special inspection requirement — Standpipe Systems
MAURICIO ANDRADE
10/11/2024
Filed — Alteration CO
INSTALL NEW SPRINKLER/STANDPIPE AND PLUMBING SYSTEMS, FILED AS SUBSEQUENT FILING FOR ALTERATION CO, B00487186-I1 AS PER 2007 NFPA13-2007, NFPA14-2007, NFPA20-2007, 2014 BUILDING CODE AND 2014 PLUMBING CODE.
B00487186-P5
10/07/2024
Signed off — Alteration
INSTALLATION OF PIPE SCAFFOLDING AS PER PLANS. ALL EQUIPMENT SHALL COMPLY WITH CHAPTER # 33 OF THE 2022 CODE. NO CHANGE IN USE OCCUPANCY OR EGRESS UNDER THIS APPLICATION.
B01071121-I1
10/02/2024
Inspection — Pass-Final CND-Occupancy Inspection
Pass
View inspection ↗
09/30/2024
Special inspection requirement — Fire-Resistant Penetrations and Joints
MAURICIO ANDRADE
09/30/2024
Special inspection requirement — Standpipe Systems
MAURICIO ANDRADE
09/30/2024
Special inspection requirement — Sprinkler Systems
MAURICIO ANDRADE
09/18/2024
Filed — Alteration CO
INSTALL NEW SPRINKLER/STANDPIPE AND PLUMBING SYSTEMS, FILED AS SUBSEQUENT FILING FOR ALTERATION CO, B00487186-I1 AS PER 2007 NFPA13-2007, NFPA14-2007, NFPA20-2007, 2014 BUILDING CODE AND 2014 PLUMBING CODE.
B00487186-P4
08/29/2024
Signed off — Alteration CO
INSTALL NEW SPRINKLER/STANDPIPE AND PLUMBING SYSTEMS, FILED AS SUBSEQUENT FILING FOR ALTERATION CO, B00487186-I1 AS PER 2007 NFPA13-2007, NFPA14-2007, NFPA20-2007, 2014 BUILDING CODE AND 2014 PLUMBING CODE.
B00487186-S1
08/20/2024
Special inspection requirement — Fire-Resistance Rated Construction
MAURICIO ANDRADE
08/20/2024
Special inspection requirement — Fire-Resistant Penetrations and Joints
MAURICIO ANDRADE
08/20/2024
Special inspection requirement — Structural Stability – Alterations of existing buildings
MAURICIO ANDRADE
08/12/2024
Filed — Alteration CO
INSTALL NEW SPRINKLER/STANDPIPE AND PLUMBING SYSTEMS, FILED AS SUBSEQUENT FILING FOR ALTERATION CO, B00487186-I1 AS PER 2007 NFPA13-2007, NFPA14-2007, NFPA20-2007, 2014 BUILDING CODE AND 2014 PLUMBING CODE.
B00487186-P3
08/09/2024
Special inspection requirement — Fire-Resistant Penetrations and Joints
MAURICIO ANDRADE
08/09/2024
Special inspection requirement — Sprinkler Systems
MAURICIO ANDRADE
08/09/2024
Special inspection requirement — Standpipe Systems
MAURICIO ANDRADE
Latest 60 of 155 events.
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
6301 12TH AVE LLC103/22/2026
TSANG CONSTRUCTION803/22/2026
PROMONT203/22/2026
12 AVE REAL PROPERTY403/21/2026
SISTERS OF MERCY OF THE AMERICAS303/21/2026
▾Sales History (ACRIS)
DatePriceUnitSeller → Buyer$/sf
12/22/2020$9.0M—JJSS DH LLC → 6301 12TH AVE LLC$135/sf building
08/15/2018$37.5M—Private party → JJSS DH LLC$564/sf building
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
LESTER KATZ, NCARB1908/03/2026
FL&M ENGINEERING DESIGN &INSPECTION106/25/2024
BASIC GROUPS CORP107/11/2019
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
EXPEDITER GROUP3003/21/2026
BDF DESIGN203/21/2026
BASIC GROUPS203/21/2026
THE GREEN STUDIO103/21/2026
MILLENNIUM DESIGNS103/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
TOWNHOUSE BUILDERS INCGeneral Contractor1407/08/2026
AKIVA MITTELMANElectrical503/21/2026
SAFETY FIRE SPRINKLER CORPFire Protection407/08/2026
PRIME ELECTRICAL CORP 004560General Contractor403/22/2026
L&J PLG & HTG CO OF NY INPlumbing307/08/2026
TSANG CONSTRUCTION, INCGeneral Contractor307/08/2026
CREATIVE PLUMBING INPlumbing307/08/2026
DYNAMIX SCAFFOLD GROUP LLGeneral Contractor203/21/2026
STAR ELEC'L CONTRACTORS CElectrical103/22/2026
LESTER KATZElectrical103/21/2026
GREEN STAR ELECTL CONT INElectrical103/22/2026
VILLAGE ELECTL CONTRS INCElectrical103/22/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
PSI AGENCY INC.2541308/03/2026
BIG APPLE GROUP NY A RMA9168207/01/2021
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWGeneral ConstructionPermit IssuedTOWNHOUSE BUILDERS INC07/29/2025
DOB NOWMechanical SystemsSigned-offTOWNHOUSE BUILDERS INC12/19/2024
DOB NOWPlumbingSigned-offSAFETY FIRE SPRINKLER CORP11/29/2024
DOB NOWSprinklersSigned-offSAFETY FIRE SPRINKLER CORP11/29/2024
DOB NOWGeneral ConstructionPermit IssuedTOWNHOUSE BUILDERS INC08/06/2024
DOB NOWSupported ScaffoldSigned-offDYNAMIX SCAFFOLD GROUP LL06/25/2024
DOB NOWSprinklersSigned-offAB PLUMBING INC02/20/2024
DOB NOWStandpipeSigned-offSAFETY FIRE SPRINKLER CORP10/25/2023
DOB NOWStandpipeSigned-offSAFETY FIRE SPRINKLER CORP10/25/2023
DOB NOWStructuralSigned-offTOWNHOUSE BUILDERS INC08/21/2023
DOB NOWGeneral ConstructionPermit IssuedTOWNHOUSE BUILDERS INC06/28/2023
DOB NOWSprinklersSigned-offAB PLUMBING INC02/23/2023
DOB NOWStructuralSigned-offTOWNHOUSE BUILDERS INC08/30/2022
DOB NOWGeneral ConstructionPermit IssuedTOWNHOUSE BUILDERS INC07/19/2022
DOB NOWStandpipeSigned-offAB PLUMBING INC06/17/2022
DOB NOWStandpipeSigned-offL&J PLG & HTG CO OF NY IN02/12/2022
DOB NOWPlumbingSigned-offL&J PLG & HTG CO OF NY IN02/02/2022
DOB NOWStructuralSigned-offTOWNHOUSE BUILDERS INC09/07/2021
DOB NOWGeneral ConstructionPermit IssuedTOWNHOUSE BUILDERS INC07/23/2021
DOB NOWConstruction FenceSigned-offTOWNHOUSE BUILDERS INC02/08/2021
DOB NOWPlumbingSigned-offL&J PLG & HTG CO OF NY IN02/05/2021
DOB NOWGeneral ConstructionSigned-offTOWNHOUSE BUILDERS INC01/21/2021
DOB NOWConstruction FenceSigned-offTSANG CONSTRUCTION, INC03/24/2020
DOB NOWConstruction FenceSigned-offTSANG CONSTRUCTION, INC03/18/2020
DOB NOWConstruction FenceSigned-offTSANG CONSTRUCTION, INC07/12/2019
BISOTISSUEDCELTIC SERVICES NYC INC08/06/2020
BISMHISSUEDLTB MECHANICAL CORP03/22/2017
BISEQISSUEDOUTDOOR INSTALLATIONS LLC06/09/2011
BISEQISSUEDOUTDOOR INSTALLATIONS LLC06/09/2011
BISEQISSUEDOUTDOOR INSTALLATIONS LLC03/30/2010
BISEQISSUEDOUTDOOR INSTALLATIONS LLC03/24/2010
BISEQISSUEDOUTDOOR INSTALLATIONS LLC03/24/2010
BISOTISSUEDHENRY RESTORATION LTD01/08/2010
BISOTISSUEDHENRY RESTORATION LTD01/20/2009
BISOTISSUEDHENRY RESTORATION LTD10/28/2008
BISEQISSUEDOUTDOOR INSTALLATIONS LLC05/01/2007
BISOTISSUEDBETA STEAM & POWER INC09/25/1991
BISFSISSUEDBETA STEAM AND POWER, INC.07/25/1991
BISPLISSUEDST. MARKS PLUMBING CO.07/25/1991
▾Field Inspections (DOB CAP) — 13
DateTypeResultReport
12/23/2025Pass-Final PL - Up to 3 Requested FloorsPassView ↗
01/16/2025Pass-Final CND-Occupancy InspectionPassView ↗
12/09/2024Pass-Final CND-Occupancy InspectionPassView ↗
12/04/2024Certified Sprinkler-Dry Pipe Valve (SP)-Dry Pipe Valve TestCertifiedView ↗
12/04/2024Certified Sprinkler-SP-Fixtures-FinishCertifiedView ↗
12/04/2024Certified StandPipe-SD-Fixtures-Finish-SDCertifiedView ↗
12/03/2024Pass-Final CND-Occupancy InspectionPassView ↗
11/28/2024Certified Sprinkler (SP) - Booster Pump TestCertifiedView ↗
11/28/2024Certified Sprinkler-SP-Piping Dry/Wet-Hydrostatic TestCertifiedView ↗
11/28/2024Certified StandPipe-SD-Piping-Hydrostatic TestCertifiedView ↗
10/02/2024Pass-Final CND-Occupancy InspectionPassView ↗
06/02/2023Certified Storm Drainage-ST-Piping-RoughingCertifiedView ↗
06/02/2023Certified Water and Sanitary-WS-Sanitary Piping-RoughingCertifiedView ↗
▾Special Inspection Requirements (DOB NOW) — 36
DateRequirementInspectorRole
08/21/2026Fire-Resistance Rated ConstructionMAURICIO ANDRADEprogress
08/21/2026Fire-Resistant Penetrations and JointsMAURICIO ANDRADEspecial
08/21/2026Structural Stability – Alterations of existing buildingsMAURICIO ANDRADEspecial
08/03/2026Structural Stability – Alterations of existing buildingsMAURICIO ANDRADEspecial
08/03/2026Fire-Resistant Penetrations and JointsMAURICIO ANDRADEspecial
08/03/2026Fire-Resistance Rated ConstructionMAURICIO ANDRADEprogress
07/07/2026Fire-Resistance Rated ConstructionMAURICIO ANDRADEprogress
07/07/2026Fire-Resistant Penetrations and JointsMAURICIO ANDRADEspecial
07/07/2026Structural Stability – Alterations of existing buildingsMAURICIO ANDRADEspecial
03/17/2025Public Assembly Emergency LightingMAURICIO ANDRADEprogress
03/03/2025Fire-Resistance Rated ConstructionMAURICIO ANDRADEprogress
03/03/2025Fire-Resistant Penetrations and JointsMAURICIO ANDRADEspecial
03/03/2025Structural Stability – Alterations of existing buildingsMAURICIO ANDRADEspecial
02/28/2025Public Assembly Emergency LightingMAURICIO ANDRADEprogress
11/14/2024Fire-Resistant Penetrations and JointsMAURICIO ANDRADEspecial
11/14/2024Sprinkler SystemsMAURICIO ANDRADEspecial
11/14/2024Standpipe SystemsMAURICIO ANDRADEspecial
09/30/2024Fire-Resistant Penetrations and JointsMAURICIO ANDRADEspecial
09/30/2024Standpipe SystemsMAURICIO ANDRADEspecial
09/30/2024Sprinkler SystemsMAURICIO ANDRADEspecial
08/20/2024Fire-Resistance Rated ConstructionMAURICIO ANDRADEprogress
08/20/2024Fire-Resistant Penetrations and JointsMAURICIO ANDRADEspecial
08/20/2024Structural Stability – Alterations of existing buildingsMAURICIO ANDRADEspecial
08/09/2024Fire-Resistant Penetrations and JointsMAURICIO ANDRADEspecial
08/09/2024Sprinkler SystemsMAURICIO ANDRADEspecial
Latest 25 of 36.
▾Documents — 286 on file (BIS + DOB NOW)
▸Plans & Drawings21
▸DOB NOWPlans/Sketch14
08/31/2026B00487186-S3Request digital key ↗
08/31/2026B00487186-S1Request digital key ↗
08/31/2026B00487186-I1Request digital key ↗
Showing 3 of 14 on file for this type
▸DOB NOWPlans/Sketch - Place of Assembly2
08/14/2026B01076539-I1Request digital key ↗
08/14/2026B01076539-P1Request digital key ↗
▸DOB NOWPlans/Sketch - Construction Fence2
09/02/2026B00192394-I1Request digital key ↗
08/15/2026B00453525-I1Request digital key ↗
▸DOB NOWPlans/Sketch - General Construction2
09/01/2026B00451309-P1Request digital key ↗
09/01/2026B00451309-I1Request digital key ↗
▸DOB NOWPlans/Sketch - Plumbing1
09/01/2026B00451309-S1Request digital key ↗
▸Applications & Permits61
▸BISPLAN / WORK APPROVAL APPLICATION33
12/17/2024320873480Open ↗
11/14/2024320873480Open ↗
08/29/2024301349020Open ↗
Showing 3 of 33 on file for this type
▸DOB NOWLPC Approval/Permit16
08/31/2026B00487186-P9Open ↗
08/31/2026B00487186-P8Open ↗
08/13/2026B00487186-P4Open ↗
Showing 3 of 16 on file for this type
▸BISWORK PERMIT APPLICATION11
08/06/2020340746134Open ↗
03/28/2017321404459Open ↗
12/05/2013320873480Open ↗
Showing 3 of 11 on file for this type
▸BISCERTIFICATE OF OCCUPANCY: APPLICATION1
12/20/2013320873480Open ↗
▸Zoning, Tax Lot & Property Records6
▸BISTAX LOT: TENTATIVE LOT NUMBER ISSUED2
06/22/2023322113093Open ↗
09/10/2020322069373Open ↗
▸BISZONING APPEAL1
10/22/2018321848916Open ↗
▸BISZONING EXHIBIT III:DESC. & OWNRSHP.STMNT1
09/10/2020322069373Open ↗
▸BISZONING EXHIBIT I: CERTIFICATION1
09/10/2020322069373Open ↗
▸DOB NOWHouse Number Verification: TOPO Stamp1
08/13/2026B00487186-I1Open ↗
▸Seals & Professional Certifications71
▸DOB NOWDPL-1: Design Professional Seal & Signature21
09/01/2026B00451309-S1Open ↗
09/01/2026B00451309-P1Open ↗
09/01/2026B00451309-I1Open ↗
Showing 3 of 21 on file for this type
▸DOB NOWSpecial Inspector Seal & Signature15
09/25/2026B00487186-P7Open ↗
09/25/2026B00487186-P7Open ↗
09/05/2026B00487186-S1Open ↗
Showing 3 of 15 on file for this type
▸BISTECHNICAL REPORT: RESPONSIBILITY/CERTIFICATION12
08/27/2018321769868Open ↗
06/20/2017321404459Open ↗
06/20/2017321404459Open ↗
Showing 3 of 12 on file for this type
▸DOB NOWProgress Inspector Seal & Signature9
09/25/2026B00487186-P7Open ↗
09/05/2026B00487186-S1Open ↗
08/29/2026B00487186-P8Open ↗
Showing 3 of 9 on file for this type
▸BISPROFESSIONAL CERTIFIED CHECKLIST6
06/16/2016321404459Open ↗
06/13/2011320319286Open ↗
06/13/2011320319277Open ↗
Showing 3 of 6 on file for this type
▸BISPROFESSIONAL CERTIFICATION STATEMENT FORM5
06/13/2011320319286Open ↗
06/13/2011320319277Open ↗
04/05/2010320141985Open ↗
Showing 3 of 5 on file for this type
▸BISPROFESSIONAL CERTIFICATION STATEMENT1
06/16/2016321404459Open ↗
▸BISAPPLICANT OWNER SIGNATURE1
07/17/2020340746134Open ↗
▸BISTECHNICAL REPORT STATEMENT OF RESPONSIBILITY1
07/20/2020340746134Open ↗
▸Trade Schedules & Equipment4
▸BISEQUIPMENT USE APPLICATION/PERMIT2
06/20/2017321404459Open ↗
06/20/2017321404459Open ↗
▸BISEQUIPMENT USE PERMITS2
06/20/2017321404459Open ↗
06/13/2017321404459Open ↗
▸Safety & Tenant Protection11
▸DOB NOWStreet Tree Checklist7
08/31/2026B00487186-P4Open ↗
08/31/2026B00487186-P1Open ↗
08/31/2026B00487186-I1Open ↗
Showing 3 of 7 on file for this type
▸BISST-1 Street Tree Checklist1
11/16/2013320873480Open ↗
▸BISTenant Protection Plan and Notes1
07/20/2020340746134Open ↗
▸BISDEMOLITION SUBMITTAL CERTIFICATION FORM1
07/24/2020340746134Open ↗
▸BISSTREET TREE CHECKLIST1
08/27/2018321769868Open ↗
▸Environmental & Asbestos14
▸DOB NOWDEP ACP-20/ACP-21: Asbestos Project Conditional Completion Form/Asbestos Project Completion Form4
08/31/2026B00487186-I1Open ↗
08/31/2026B00487186-S4Open ↗
08/31/2026B00487186-S3Open ↗
Showing 3 of 4 on file for this type
▸BISTHIS IS 'NOT AN ASBESTOS PROJECT'3
06/13/2011320319286Open ↗
03/25/2010320138007Open ↗
10/21/2008310214201Open ↗
▸BISASBESTOS EXEMPTION CERTIFICATION LETTER3
06/13/2011320319277Open ↗
04/05/2010320141985Open ↗
03/25/2010320138016Open ↗
▸DOB NOWDEP ACP-5: Asbestos Assessment Report3
09/01/2026B00451309-S1Open ↗
09/01/2026B00451309-I1Open ↗
09/01/2026B00451309-P1Open ↗
▸BISASBESTOS: CERTIFICATION (DEP ACP5)1
07/28/2020340746134Open ↗
▸Energy Compliance14
▸BISTECHNICAL REPORT: ENERGY CODE - RESPONSIBILITY5
08/20/2024340746134Open ↗
07/30/2024340746134Open ↗
06/29/2023340746134Open ↗
Showing 3 of 5 on file for this type
▸BISENERGY CODE COMPLIANCE INSPECTIONS2
07/30/2024340746134Open ↗
07/30/2024340746134Open ↗
▸BISTECHNICAL REPORT: ENERGY CODE PROGRESS INSPS2
06/20/2017321404459Open ↗
06/16/2016321404459Open ↗
▸BISTECHNICAL REPORT STATEMENT OF RESPONSIBILITY FOR ENERGY CODE PROGRESS INSPECTIONS1
07/20/2020340746134Open ↗
▸BISINTERIOR LIGHTING POWER1
07/30/2024340746134Open ↗
▸BISAS-BUILT ENERGY ANALYSIS1
06/20/2017321404459Open ↗
▸BISLIGHTING CONTROLS1
07/30/2024340746134Open ↗
▸BISAS-BUILT ENERGY ANALYSIS (EN2)1
07/30/2024340746134Open ↗
▸Inspections & Test Reports16
▸BISTECHNICAL REPORT: RESPONSIBILITY9
08/20/2024340746134Open ↗
08/20/2024340746134Open ↗
07/30/2024340746134Open ↗
Showing 3 of 9 on file for this type
▸BISSTRUCTURAL STABILITY - ALTERATIONS OF EXISTING BUILDINGS2
07/30/2024340746134Open ↗
07/30/2024340746134Open ↗
▸BISFIRE-RESISTANT PENETRATIONS AND JOINTS (FIRESTOP)2
07/30/2024340746134Open ↗
07/30/2024340746134Open ↗
▸BISFIRE-RESISTIVE RATED CONSTRUCTION2
07/30/2024340746134Open ↗
07/30/2024340746134Open ↗
▸BISFINAL INSPECTION REQUIRED1
08/15/2024340746134Open ↗
▸Approvals, Objections & Sign-offs30
▸BISLETTERS - SUPPORTING DOCUMENTATION11
06/22/2023322113093Open ↗
11/09/2020340746134Open ↗
09/10/2020322069373Open ↗
Showing 3 of 11 on file for this type
▸BISCERTIFICATE OF OCCUPANCY/LOC: REQUEST8
08/21/2024340746134Open ↗
06/20/2017321404459Open ↗
03/23/2012320319277Open ↗
Showing 3 of 8 on file for this type
▸BISADMINISTRATIVE OBJECTIONS7
11/16/2013320873480Open ↗
06/13/2011320319286Open ↗
06/13/2011320319277Open ↗
Showing 3 of 7 on file for this type
▸BISSCHEDULE A - OCCUPANCY - USE3
11/16/2013320873480Open ↗
11/16/2013320873480Open ↗
08/27/2018321769868Open ↗
▸BISThird Party Electrical Signoff Compliance Report1
03/23/2012320319277Open ↗
▸Cost, Insurance & Ownership7
▸BISCOST AFFIDAVIT6
07/28/2020340746134Open ↗
08/27/2018321769868Open ↗
06/20/2017321404459Open ↗
Showing 3 of 6 on file for this type
▸BISCOST AFFIDAVIT (FINAL): PW31
07/30/2024340746134Open ↗
▸Filing & Intake Forms21
▸BISEFILING COVER SHEET13
05/24/2023322113093Open ↗
07/22/2020322087353Open ↗
10/10/2018321848916Open ↗
Showing 3 of 13 on file for this type
▸BISADDITIONAL INFORMATION5
06/22/2023322113093Open ↗
11/09/2020340746134Open ↗
07/20/2020340746134Open ↗
Showing 3 of 5 on file for this type
▸BISBOROUGH INTAKE FORM2
11/16/2018321829161Open ↗
11/16/2018321769868Open ↗
▸BISEFILING JOB APPLICATION COVER SHEET1
07/17/2020340746134Open ↗
▸Other Documents10
▸BISPLOT DIAGRAM3
06/23/2023322113093Open ↗
06/22/2023322113093Open ↗
10/22/2018321848916Open ↗
▸BISRECORDS MGMT FEE PAYMENT RECEIPT2
06/22/2023322113093Open ↗
09/10/2020322069373Open ↗
▸BISCALENDARED PROPERTY - 40-DAY HOLD2
09/10/2020322069373Open ↗
07/20/2020340746134Open ↗
▸DOB NOWAlternate Plan 12
08/14/2026B01076539-I1Open ↗
08/14/2026B01076539-P1Open ↗
▸BISEXTERNAL FORMS - SUPPORTING DOCUMENTATION1
10/22/2018321848916Open ↗