← Back
BuildNYC
Three families
6304 12TH AVENUE
BROOKLYN · Dyker Heights · BIN 3141792
💬 Discuss this project
1980Year Built
3Stories
C0Building Class
R5BZoning
3,906 sfGross Floor Area
3Units
Rent Stabilized2 Active Violations ▸FDNY Report ↗
Three families · 2,790 sf lot · 1.4 FAR built · Flood zone X
Locations of Work
Architecture
Names shown beside floors are taken automatically from the text of filed documents and may be incomplete or wrong.
Site & exteriorRemove CMU wall from driveway1p · 1 filing · 3 docs
▾Sales History (ACRIS)
DatePriceUnitSeller → Buyer$/sf
06/15/2023$2.1M—Private party → Private party$550/sf building
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
Mei Architect101/09/2024
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
Ibuild Consulting203/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
L&L Construction DevelopmentGeneral Contractor107/08/2026
Building Lifecycle
All (20)Filed (1)Permit Issued (1)Signed Off (1)Violation (14)Inspection (1)Objection (2)
04/30/2026
Violation issued (HPD, open)
A
11/19/2025
Violation issued (HPD, closed)
I
06/05/2025
Violation issued (HPD, open)
A
04/03/2024
Violation issued (HPD, closed)
A
03/15/2024
Signed off — Alteration
REMOVE CMU WALL INSTALLED IN THE DRIVEWAY AS PER THE PLAN FILED HEREWITH TO REMOVE VIOLATION #35671452X. NO CHANGE IN USE, OCCUPANCY OR EGRESS.
B00987273-I1
03/14/2024
Inspection — Pass-Final General Construction Non-Directive 14
Pass
View inspection ↗
02/26/2024
Permit issued — General Construction
B00987273-I1-GC
01/18/2024
Objection resolved — Addressed
01/17/2024
Objection raised — Scope
01/09/2024
Filed — Alteration
REMOVE CMU WALL INSTALLED IN THE DRIVEWAY AS PER THE PLAN FILED HEREWITH TO REMOVE VIOLATION #35671452X. NO CHANGE IN USE, OCCUPANCY OR EGRESS.
B00987273-I1
11/20/2023
Violation issued (HPD, closed)
I
10/26/2023
Violation issued (ECB, closed)
Construction
11/09/2022
Violation issued (HPD, closed)
I
02/18/2022
Violation issued (HPD, closed)
I
02/18/2022
Violation issued (HPD, closed)
A
04/05/2021
Violation issued (HPD, closed)
A
04/05/2021
Violation issued (HPD, closed)
I
10/28/2019
Violation issued (HPD, closed)
I
10/12/2018
Violation issued (HPD, closed)
I
11/15/2017
Violation issued (HPD, closed)
I
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWGeneral ConstructionSigned-offL&L Construction Development02/26/2024
1 project · most recent 06/30/2023
FiledStatusContractorScope
06/30/2023CompleteKwong Ming Electric4 meters, 4 new_meters
▾Field Inspections (DOB CAP) — 1
DateTypeResultReport
03/14/2024Pass-Final General Construction Non-Directive 14PassView ↗
▾Documents — 3 on file (BIS + DOB NOW)
▸Plans & Drawings1
▸DOB NOWPlans/Sketch1
08/26/2026B00987273-I1Request digital key ↗
▸Seals & Professional Certifications1
▸DOB NOWDPL-1: Design Professional Seal & Signature1
08/26/2026B00987273-I1Open ↗
▸Environmental & Asbestos1
▸DOB NOWDEP ACP-5: Asbestos Assessment Report1
08/26/2026B00987273-I1Open ↗