← Back
Predominantly retail with other uses
6306 18 AVENUE
BROOKLYN · Bensonhurst · BIN 3133111
💬 Discuss this project
1931Year Built
3Stories
K4Building Class
C4-2Zoning
3,420 sfGross Floor Area
3Units
0 Open ViolationsFDNY Report ↗
Predominantly retail with other uses · Owner of record: 6306 18TH AVENUE LLC · 1,427 sf lot · 2.4 FAR built · Flood zone X
Locations of Work
ArchitectureMechanical
Roof15p · 1 filing · 3 docs
Floor 113p · 1 filing · 3 docs
Cellar13p · 1 filing · 3 docs
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
6902 18 AVENUE1607/08/2026
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
RICHARD WAINER ARCHITECT, PLLC108/30/2023
CHERICO KING ARCHITECT, P.C.307/25/2023
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
CHERICO KING ARCHITECT P C603/21/2026
D R BROWN203/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
MICHELLE KUO CORPGeneral Contractor403/21/2026
AI FANG WUElectrical103/21/2026
AUR0RA ELECL CONTG INCElectrical103/22/2026
TRI STATE PLBG & HTG INCPlumbing107/08/2026
TEE BEE SIGN INSTScaffold107/08/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
CHERICO KING ARCHITECT PC5674207/25/2023
Building Lifecycle
All (31)Filed (4)Permit Issued (4)Signed Off (1)Violation (8)Inspection (4)Objection (4)Special Inspection (6)
10/16/2023
Inspection — Certified Remove/Cap - work done in accordance with code
Certified
View inspection ↗
10/16/2023
Inspection — Certified Water and Sanitary-WS-Fixtures-Finish
Certified
View inspection ↗
09/26/2023
Signed off — Alteration
Erect illuminated sign on wall. No change of use, egress or occupancy
B00922005-I1
09/01/2023
Permit issued — Sign
B00922005-I1-SG
08/30/2023
Filed — Alteration
Erect illuminated sign on wall. No change of use, egress or occupancy
B00922005-I1
08/19/2023
Special inspection requirement — Final
Richard Wainer
08/16/2023
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Roughing
Certified
View inspection ↗
08/16/2023
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Underground
Certified
View inspection ↗
07/28/2023
Permit issued — Plumbing
B00832427-I1-PL
07/27/2023
Objection raised — Structural
07/27/2023
Objection resolved — Addressed
07/27/2023
Objection raised — Scope
07/27/2023
Objection resolved — Addressed
07/25/2023
Filed — Alteration
INSTALLATION OF PLUMBING FIXTURES & HWH INCONJUNCTION OF GC APPLICATION B00832418
B00832427-I1
07/25/2023
Special inspection requirement — Fire-Resistant Penetrations and Joints
Cherico King
07/25/2023
Special inspection requirement — Energy Code Compliance Inspections
Cherico King
07/25/2023
Special inspection requirement — HVAC-R and service water piping design and insulation
Cherico King
07/25/2023
Special inspection requirement — HVAC-R and service water heating equipment
Cherico King
07/25/2023
Special inspection requirement — HVAC-R and service water heating system controls
Cherico King
07/11/2023
Permit issued — Construction Fence
B00832422-I1-FN
06/20/2023
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
06/13/2023
Permit issued — General Construction
B00832418-I1-GC-CX
06/08/2023
Filed — Alteration
B00832422-I1
06/06/2023
Filed — Alteration
RENOVATION OF EXT'G STORE ON 1ST FLOOR OF BLD'G. REPLACE EXISTING CEILING, FLOOR TILES, LIGHT, WALL FINISHES, STOREFRONT. & INSTALL NEW MINI SPLIT AC UNITS WITH EXT'G DUCT PENETRATIONS NO WORK ON EXT'G ROOF MATERIAL, NO CHANGE IN USE, EGRESS OR OCCUPANCY.
B00832418-I1
06/15/2021
Violation issued (FDNY_NOV, closed)
06/03/2021
Violation issued (FDNY_NOV, closed)
06/03/2021
Violation issued (FDNY_NOV, closed)
05/10/2021
Violation issued (FDNY_NOV, closed)
11/08/2019
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
08/29/1995
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
01/23/1989
Violation issued (ECB, closed)
Construction
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWSignSigned-offWEINFELD, ELLIOT09/01/2023
DOB NOWPlumbingSigned-offDW PLUMBING INC07/28/2023
DOB NOWConstruction FencePermit Issued18-15 REALTY LLC07/11/2023
DOB NOWGeneral ConstructionPermit Issued18-15 REALTY LLC06/13/2023
BISFPISSUEDNY FIRE LLC09/02/2011
BISPLISSUEDBROOK PLUMBING & HTG CORP04/26/2011
BISOTISSUEDHANDSOME ENTERPRISES INC04/06/2011
BISPLISSUEDTOP DOG PLBG & HTG CORP04/03/2009
BISOTISSUEDTRIPLE 8 CONSTRUCTION INC03/18/2009
1 project · most recent 06/06/2023
Associated Ducts and Piping Heating and Air Conditioning Systems Ventilation Systems
FiledStatusContractorScopeMake / Model / Capacity
06/06/2023Permit IssuedMICHELLE KUO CORPAssociated Ducts and Piping, Heating and Air Conditioning Systems, Ventilation Systems
Heat / Cool
Mitsubishi Electric MXZ-SM48NAM 48,000 BTU · Heat Pump Outdoor ×1
MXZ-SM60NAM 60,000 BTU · Heat Pump Outdoor ×1
Ventilation
Greenheck SQ-95-VG6X-QD 800 CFM · Kitchen Exhaust ×2
Ducts & Piping
__Junk__ DUTWORK & PIPING WORK 1 CFM · Ductwork ×1
1 project · most recent 07/25/2023
Water/Sanitary
FiledStatusContractorScope
07/25/2023Signed-offTRI STATE PLBG & HTG INCWater/Sanitary
2 projects · most recent 09/03/2023
General Wiring
FiledStatusContractorScope
09/03/2023Permit IssuedAUR0RA ELECL CONTG INC—
06/27/2023CompleteJEM ELEC'L CONTR. CORPGeneral Wiring
▾Field Inspections (DOB CAP) — 4
DateTypeResultReport
10/16/2023Certified Remove/Cap - work done in accordance with codeCertifiedView ↗
10/16/2023Certified Water and Sanitary-WS-Fixtures-FinishCertifiedView ↗
08/16/2023Certified Water and Sanitary-WS-Sanitary Piping-RoughingCertifiedView ↗
08/16/2023Certified Water and Sanitary-WS-Sanitary Piping-UndergroundCertifiedView ↗
▾Special Inspection Requirements (DOB NOW) — 6
DateRequirementInspectorRole
08/19/2023FinalRichard Wainerprogress
07/25/2023Fire-Resistant Penetrations and JointsCherico Kingspecial
07/25/2023Energy Code Compliance InspectionsCherico Kingprogress
07/25/2023HVAC-R and service water piping design and insulationCherico Kingenergy_progress
07/25/2023HVAC-R and service water heating equipmentCherico Kingenergy_progress
07/25/2023HVAC-R and service water heating system controlsCherico Kingenergy_progress
▾Tenants in the building
TenantSpaceFloorsRenovation projects
Dunkin'Restaurant / Food ServiceFloor 1
Project B00832418 Alteration · Permit Entire · 06/06/2023
Read from each project’s drawing title blocks and cover sheets and checked twice; a name appears only when it is the occupant, never the owner, landlord or designer.
▾Documents — 49 on file (BIS + DOB NOW)
▸Plans & Drawings4
▸DOB NOWPlans/Sketch4
08/27/2026B00832418-I1Request digital key ↗
08/27/2026B00832422-I1Request digital key ↗
08/27/2026B00832427-I1Request digital key ↗
Showing 3 of 4 on file for this type
▸Applications & Permits8
▸BISWORK PERMIT APPLICATION5
09/21/2011320322316Open ↗
04/28/2011320276241Open ↗
04/08/2011320276241Open ↗
Showing 3 of 5 on file for this type
▸BISPLAN / WORK APPROVAL APPLICATION3
06/22/2011320322316Open ↗
03/01/2011320276241Open ↗
03/17/2009310312827Open ↗
▸Seals & Professional Certifications19
▸BISTECHNICAL REPORT: RESPONSIBILITY/CERTIFICATION7
09/21/2011320322316Open ↗
06/22/2011320322316Open ↗
04/07/2011320276241Open ↗
Showing 3 of 7 on file for this type
▸DOB NOWProgress Inspector Seal & Signature5
08/27/2026B00832427-I1Open ↗
08/27/2026B00832427-I1Open ↗
08/27/2026B00832427-I1Open ↗
Showing 3 of 5 on file for this type
▸DOB NOWDPL-1: Design Professional Seal & Signature4
08/27/2026B00832422-I1Open ↗
08/27/2026B00832427-I1Open ↗
08/13/2026B00922005-I1Open ↗
Showing 3 of 4 on file for this type
▸BISPROFESSIONAL CERTIFIED CHECKLIST1
03/17/2009310312827Open ↗
▸BISPROFESSIONAL CERTIFICATION STATEMENT FORM1
03/17/2009310312827Open ↗
▸DOB NOWSpecial Inspector Seal & Signature1
08/27/2026B00832427-I1Open ↗
▸Trade Schedules & Equipment3
▸BISSCHEDULE B - PLUMBING2
03/01/2011320276241Open ↗
03/17/2009310312827Open ↗
▸BISSELF-CERT PLUMBING NOTICE1
05/18/2009310312827Open ↗
▸Environmental & Asbestos5
▸DOB NOWDEP ACP-5: Asbestos Assessment Report3
08/27/2026B00832427-I1Open ↗
08/13/2026B00922005-I1Open ↗
08/13/2026B00832418-I1Open ↗
▸BISTHIS IS 'NOT AN ASBESTOS PROJECT'1
03/01/2011320276241Open ↗
▸BISASBESTOS EXEMPTION CERTIFICATION LETTER1
03/17/2009310312827Open ↗
▸Energy Compliance1
▸BISTECHNICAL REPORT: ENERGY1
04/07/2011320276241Open ↗
▸Approvals, Objections & Sign-offs3
▸BISADMINISTRATIVE OBJECTIONS3
06/22/2011320322316Open ↗
03/01/2011320276241Open ↗
03/17/2009310312827Open ↗
▸Cost, Insurance & Ownership3
▸BISCOST AFFIDAVIT3
06/22/2011320322316Open ↗
03/01/2011320276241Open ↗
03/17/2009310312827Open ↗
▸Filing & Intake Forms3
▸BISEFILING COVER SHEET3
06/22/2011320322316Open ↗
03/01/2011320276241Open ↗
03/17/2009310312827Open ↗