RoofUnder Construction39p · 7 filings · 20 docs
ArchitectureGeneralMechanicalStructural
Issued Permit Scope
General Construction · Supported Scaffold
Installation of outrigger for facade repair & inspection.
On file for this job
5 documents · 1 drawing sheet
Structural modifications taking place on the 2nd and 11th floor setback roofs as indicated on the drawings.
On file for this job
13 documents · 13 drawing sheets
Proposed installation of temporary parapet protection extension / shield during roofing work. No change in use, egress, or occupancy for this filing for this job. It is classified here under scaffolding installation for DOB job filing purposes.
On file for this job
2 documents
Latest 3 of 7 filings on this floor.
Bulkhead1p · 1 filing · 10 docs
Mechanical
REPLACEMENT OF COOLING TOWER CELLS AS PER PLANS FILED HEREWITH. NO CHANGE IN USE, EGRESS OR OCCUPANCY UNDER THIS APPLICATION.
On file for this job
10 documents · 1 drawing sheet
Penthouse5p · 2 filings · 13 docs
MechanicalPlumbing
REMOVAL OF (3) EXISTING COOLING TOWER MAKE-UP WATER FEED ASSEMBLIES, CONSOLIDATION TO SINGLE FEED WITH (1) WATER METER AND (1) BFP ASSEMBLY TO FEED ALL (3) COOLING TOWERS AS PER PLANS FILED HEREWITH. NO CHANGE IN USE, EGRESS OR OCCUPANCY.
On file for this job
3 documents · 2 drawing sheets
REPLACEMENT OF COOLING TOWER CELLS AS PER PLANS FILED HEREWITH. NO CHANGE IN USE, EGRESS OR OCCUPANCY UNDER THIS APPLICATION.
On file for this job
10 documents · 3 drawing sheets
Floor 391p · 1 filing · 5 docs
Structural
REMOVAL OF CONVENIENCE STAIR AND FRAMING FOR CLOSING CONVENIENCE STAIR'S OPENING ON 39TH FL AS PER PLANS FILED HEREWITH. NO CHANGE TO USE, EGRESS OR OCCUPANCY.
On file for this job
5 documents · 1 drawing sheet
Floor 38Under Construction29p · 2 filings · 20 docs
ArchitectureFire ProtectionMechanicalPlumbingStructural
Issued Permit Scope
General Construction · Mechanical Systems · Plumbing · Sprinklers · Structural
REMOVAL AND ISTALLATION OF NEW DUCTWORK AS PER PLANS FILED HEREWITH. NO CHANGE TO USE, EGRESS OR OCCUPANCY.
On file for this job
23 documents · 6 drawing sheets
REMOVAL OF CONVENIENCE STAIR AND FRAMING FOR CLOSING CONVENIENCE STAIR'S OPENING BETWEEN 37TH AND 38TH FL AS PER PLANS FILED HEREWITH. NO CHANGE TO USE, EGRESS OR OCCUPANCY.
On file for this job
3 documents
Floor 37Under Construction1p · 1 filing · 3 docs
Structural
Issued Permit Scope
Structural
REMOVAL OF CONVENIENCE STAIR AND FRAMING FOR CLOSING CONVENIENCE STAIR'S OPENING BETWEEN 37TH AND 38TH FL AS PER PLANS FILED HEREWITH. NO CHANGE TO USE, EGRESS OR OCCUPANCY.
On file for this job
3 documents
Floor 36
Floor 35
Floor 341p · 1 filing · 5 docs
Structural
No filed description on record for this job.
On file for this job
5 documents · 1 drawing sheet
Floor 331p · 1 filing · 5 docs
Structural
No filed description on record for this job.
On file for this job
5 documents · 1 drawing sheet
Floor 32
Floor 31
Floor 30
Floor 29
Floor 284p · 1 filing · 3 docs
Plumbing
Issued Permit Scope
Plumbing
Modification to plumbing system are related piping as shown on drawings filed herewith. No change in use, egress or occupancy.
On file for this job
3 documents
Floor 27
Floor 26
Floor 25
Floor 24
Floor 23
Floor 22
Floor 21
Floor 20
Floor 19Under Construction13p · 8 filings · 20 docs
ArchitectureDMFire ProtectionMechanicalPlumbingStructural
Issued Permit Scope
General Construction
PROPOSED INTERIOR RENOVATION.COMBINING EXISTING OFFICE SUITE 7,8,9 INTO ONE OFFICE SPACES. NEW PARTITIONS,ASSOCIATED CEILING AND FINISH WORK. NO CHANGE IN USE , EGRESS OR OCCUPANCY.
On file for this job
10 documents · 2 drawing sheets
Proposed installation of new executive wash room for existing commercial condominium #19C. No change to use, occupancy or egress under this application.
On file for this job
15 documents · 1 drawing sheet
FILING FOR MECHANICAL FIT OUT OF OFFICE SPACE ON 19TH FLOOR AS PER PLANS FILED HEREWITH. NO CHANGE IN EGRESS, USE OR OCCUPANCY.
On file for this job
3 documents · 1 drawing sheet
Latest 3 of 8 filings on this floor.
Floor 1811p · 5 filings · 20 docs
ArchitectureGeneralMechanicalPlumbingStructural
Issued Permit Scope
General Construction
INTERIOR RENOVATION OF EXISTING OFFICE SPACE ON THE 18TH FLOOR TO INCLUDE A PUBLIC ASSEMBLY SPACE AND MODIFY THE OCCUPANCY. NO CHANGE TO EGRESS
On file for this job
13 documents
STRUCTURAL WORK FILED IN CONJUNCTION WITH INTERIOR RENOVATION OF EXISTING OFFICE SPACE ON THE 18TH FLOOR. NO CHANGE IN USE, EGRESS OR OCCUPANCY
On file for this job
35 documents · 2 drawing sheets
HVAC removals on the 18th floor (Austrian Mission to the UN) as per plans. No change to use, egress or occupancy.
On file for this job
6 documents · 1 drawing sheet
Latest 3 of 5 filings on this floor.
Floor 17
Floor 16
Floor 154p · 1 filing · 3 docs
Plumbing
Issued Permit Scope
Plumbing
Modification to plumbing system are related piping as shown on drawings filed herewith. No change in use, egress or occupancy.
On file for this job
3 documents
Floor 14
Floor 135p · 3 filings · 11 docs
ArchitectureFire Protection
HEREBY FILING FOR THE INSTALLATION OF MECHANICAL EQUIPMENT IN RELATION TO RENOVATION OF SUITE 13D LOCATED ON THE 13TH FLOOR. NO CHANGE TO USE, EGRESS OR OCCUPANCY
On file for this job
3 documents · 3 drawing sheets
INSTALLATION OF PLUMBING FIXTURES AND SPRINKLER HEADS IN RELATION TO RENOVATION OF SUITE 13D ON THE 12TH AND 13TH FLOOR. NO CHANGE TO USE OCCUPANCY OR EGRESS.
On file for this job
5 documents · 1 drawing sheet
MODIFICATION TO EXISTING SPRINKLER SYSTEM IN OFFICE SPACES #13A & 13B AS SHOWN ON PLANS. NO CHANGE THE USE, EGRESS OR OCCUPANCY.
On file for this job
3 documents · 1 drawing sheet
Floor 125p · 2 filings · 8 docs
Plumbing
Issued Permit Scope
Plumbing
Modification to plumbing system are related piping as shown on drawings filed herewith. No change in use, egress or occupancy.
On file for this job
3 documents
INSTALLATION OF PLUMBING FIXTURES AND SPRINKLER HEADS IN RELATION TO RENOVATION OF SUITE 13D ON THE 12TH AND 13TH FLOOR. NO CHANGE TO USE OCCUPANCY OR EGRESS.
On file for this job
5 documents · 1 drawing sheet
Floor 114p · 1 filing · 3 docs
Plumbing
Issued Permit Scope
Plumbing
Modification to plumbing system are related piping as shown on drawings filed herewith. No change in use, egress or occupancy.
On file for this job
3 documents
Floor 10
Floor 94p · 2 filings · 20 docs
ArchitectureGeneralMechanical
Installation of ductwork and HVAC system in existing office space
On file for this job
17 documents · 2 drawing sheets
REPLACE EXISTING 19TH FLOOR AIR DISTRIBUTION SYSTEM WITH THE SYSTEM MATCHING FLOOR LAYOUT SHOWN ON CONSTRUCTION PLAN FILED AS JOB 140882506. POST APPROVAL AMENDMENT IS FILED TO AMEND PLANS TO AS-BUILT CONDITIONS. NO CHANGE TO COST.
On file for this job
22 documents · 3 drawing sheets
Floor 812p · 3 filings · 20 docs
MechanicalStructural
Issued Permit Scope
Mechanical Systems
FILING FOR MECHANICAL FIT OUT OF OFFICE SPACE ON 8TH FLOOR AS PER PLANS FILED HEREWITH. NO CHANGE IN EGRESS, USE OR OCCUPANCY.
On file for this job
11 documents · 4 drawing sheets
STRUCTURAL WORK FILED IN CONJUNCTION WITH INTERIOR RENOVATION OF EXISTING OFFICE SPACE ON THE 18TH FLOOR. NO CHANGE IN USE, EGRESS OR OCCUPANCY
On file for this job
35 documents · 1 drawing sheet
REPLACEMENT OF COOLING TOWER CELLS AS PER PLANS FILED HEREWITH. NO CHANGE IN USE, EGRESS OR OCCUPANCY UNDER THIS APPLICATION.
On file for this job
10 documents · 1 drawing sheet
Floor 7
Floor 6
Floor 5Under Construction30p · 5 filings · 20 docs
ArchitectureDMFire ProtectionMechanicalPlumbing
Issued Permit Scope
General Construction · Mechanical Systems · Plumbing · Sprinklers
Modification to HVAC ductwork and related piping as shown on drawings filed herewith. No change in use, egress or occupancy.
On file for this job
3 documents · 1 drawing sheet
Modification to plumbing system are related piping as shown on drawings filed herewith. No change in use, egress or occupancy.
On file for this job
3 documents
Modification to sprinkler system and related piping as shown on drawings filed herewith. No change in use, egress or occupancy.
On file for this job
4 documents
Latest 3 of 5 filings on this floor.
Floor 4Under Construction24p · 4 filings · 13 docs
ArchitectureFire ProtectionMechanicalPlumbing
Issued Permit Scope
General Construction · Mechanical Systems · Plumbing · Sprinklers
Modification to HVAC ductwork and related piping as shown on drawings filed herewith. No change in use, egress or occupancy.
On file for this job
3 documents
Modification to plumbing system are related piping as shown on drawings filed herewith. No change in use, egress or occupancy.
On file for this job
3 documents
Modification to sprinkler system and related piping as shown on drawings filed herewith. No change in use, egress or occupancy.
On file for this job
4 documents
Latest 3 of 4 filings on this floor.
Floor 3Under Construction31p · 4 filings · 13 docs
ArchitectureFire ProtectionMechanicalPlumbing
Issued Permit Scope
General Construction · Mechanical Systems · Plumbing · Sprinklers
Modification to HVAC ductwork and related piping as shown on drawings filed herewith. No change in use, egress or occupancy.
On file for this job
3 documents · 3 drawing sheets
Modification to plumbing system are related piping as shown on drawings filed herewith. No change in use, egress or occupancy.
On file for this job
3 documents
Modification to sprinkler system and related piping as shown on drawings filed herewith. No change in use, egress or occupancy.
On file for this job
4 documents · 1 drawing sheet
Latest 3 of 4 filings on this floor.
Floor 2Under Construction56p · 10 filings · 20 docs
ArchitectureDMFire ProtectionMechanicalPlumbing
Issued Permit Scope
General Construction · Mechanical Systems · Plumbing · Sprinklers
Modification to HVAC ductwork and related piping as shown on drawings filed herewith. No change in use, egress or occupancy.
On file for this job
3 documents · 3 drawing sheets
Modification to plumbing system are related piping as shown on drawings filed herewith. No change in use, egress or occupancy.
On file for this job
3 documents
Reconfiguration of offices and select bathrooms, replacement of one exterior window to provide new louver for ventilation as shown on drawings filed herewith. No change in use, egress or occupancy.
On file for this job
3 documents · 3 drawing sheets
Latest 3 of 8 filings on this floor.
Floor 17p · 5 filings · 20 docs
ArchitectureDMMechanicalPlumbing
Minor renovation to existing bank branch, including partitions for an enclosed office and associated ceiling and finish work. No change in use, egress or occupancy.
On file for this job
4 documents · 4 drawing sheets
Minor renovation to existing bank branch, including accessibility upgrade in the form of an accessibility lift and associated alterations. No change in use, egress or occupancy.
On file for this job
4 documents · 3 drawing sheets
REGISTERING EXISTING GAS EQUIPMENT ON FIRST FLOOR IN A EXISTING TAKE-OUT RESTAURANT AS PER PLANS SUBMITTED. NO CHANGE IN USE, EGRESS OR OCCUPANCY.
On file for this job
7 documents · 1 drawing sheet
Latest 3 of 5 filings on this floor.
Cellar1p · 1 filing · 10 docs
Mechanical
REPLACEMENT OF COOLING TOWER CELLS AS PER PLANS FILED HEREWITH. NO CHANGE IN USE, EGRESS OR OCCUPANCY UNDER THIS APPLICATION.
On file for this job
10 documents · 1 drawing sheet