← Back
Miscellaneous two family
633 60 STREET
BROOKLYN · Sunset Park (Central) · BIN 3016376
💬 Discuss this project
1910Year Built
2Stories
B9Building Class
R6BZoning
1,504 sfGross Floor Area
2Units
Miscellaneous two family · 1,786 sf lot · 0.84 FAR built · Flood zone X
Locations of Work
Mechanical
Cellar1p · 1 filing · 11 docs
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
ALLEN SHINFELD, P.E. PLLC203/21/2024
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
JRK CREATIVE403/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
CROSSFIELD PLBG.&HTGPlumbing107/08/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
ALLEN SHINFELD, P.E. PLLC1305203/21/2024
Building Lifecycle
All (10)Filed (2)Permit Issued (1)Signed Off (1)Inspection (1)Special Inspection (5)
04/04/2024
Signed off — Alteration
FILING THIS APPLICATION TO REPLACE 1 HWH,1 BOILER & 1INSTALL,1 NEW HWH & 1 NEW BOILER AND REPLACE 2 EXIST.GAS METERS BARS AT CELLAR.TO REPLACE 1 STOVE ON 1ST FL& 2ND FL AND REPLACE 1 DRYER ON 1ST FL,NO CHANGE OF USE,EGRESS OR OCCUPANCY
B01013080-I1
03/27/2024
Inspection — Pass-Final PL - Up to 3 Requested Floors
Pass
View inspection ↗
03/21/2024
Filed — Alteration
FILING THIS APPLICATION TO REPLACE 1 HWH,1 BOILER & 1INSTALL,1 NEW HWH & 1 NEW BOILER AND REPLACE 2 EXIST.GAS METERS BARS AT CELLAR.TO REPLACE 1 STOVE ON 1ST FL& 2ND FL AND REPLACE 1 DRYER ON 1ST FL,NO CHANGE OF USE,EGRESS OR OCCUPANCY
B01013080-P1
03/20/2024
Special inspection requirement — Tenant Protection Plan Compliance
ALLEN SHINFELD
03/20/2024
Special inspection requirement — Energy Code Compliance Inspections
ALLEN SHINFELD
03/20/2024
Special inspection requirement — HVAC-R and service water heating equipment
ALLEN SHINFELD
03/20/2024
Special inspection requirement — HVAC-R and service water heating system controls
ALLEN SHINFELD
03/20/2024
Special inspection requirement — HVAC-R and service water piping design and insulation
ALLEN SHINFELD
03/11/2024
Permit issued — Plumbing
B01013080-I1-PL
03/02/2024
Filed — Alteration
FILING THIS APPLICATION TO REPLACE 1 HWH,1 BOILER & 1INSTALL,1 NEW HWH & 1 NEW BOILER AND REPLACE 2 EXIST.GAS METERS BARS AT CELLAR.TO REPLACE 1 STOVE ON 1ST FL& 2ND FL AND REPLACE 1 DRYER ON 1ST FL,NO CHANGE OF USE,EGRESS OR OCCUPANCY
B01013080-I1
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWPlumbingSigned-offCROSSFIELD PLBG.&HTG03/11/2024
Nothing on file for this building.
▾Field Inspections (DOB CAP) — 1
DateTypeResultReport
03/27/2024Pass-Final PL - Up to 3 Requested FloorsPassView ↗
▾Special Inspection Requirements (DOB NOW) — 5
DateRequirementInspectorRole
03/20/2024Tenant Protection Plan ComplianceALLEN SHINFELDspecial
03/20/2024Energy Code Compliance InspectionsALLEN SHINFELDprogress
03/20/2024HVAC-R and service water heating equipmentALLEN SHINFELDenergy_progress
03/20/2024HVAC-R and service water heating system controlsALLEN SHINFELDenergy_progress
03/20/2024HVAC-R and service water piping design and insulationALLEN SHINFELDenergy_progress
▾Documents — 11 on file (BIS + DOB NOW)
▸Plans & Drawings2
▸DOB NOWPlans/Sketch2
08/25/2026B01013080-I1Request digital key ↗
08/25/2026B01013080-P1Request digital key ↗
▸Seals & Professional Certifications7
▸DOB NOWProgress Inspector Seal & Signature4
08/25/2026B01013080-P1Open ↗
08/25/2026B01013080-P1Open ↗
08/25/2026B01013080-P1Open ↗
Showing 3 of 4 on file for this type
▸DOB NOWDPL-1: Design Professional Seal & Signature2
08/25/2026B01013080-P1Open ↗
08/25/2026B01013080-I1Open ↗
▸DOB NOWSpecial Inspector Seal & Signature1
08/25/2026B01013080-P1Open ↗
▸Environmental & Asbestos2
▸DOB NOWDEP ACP-5: Asbestos Assessment Report2
08/25/2026B01013080-P1Open ↗
08/25/2026B01013080-I1Open ↗