← Back
Two family converted from one family
64-05 35 AVENUE
QUEENS · BIN 4027236
💬 Discuss this project
1930Year Built
2Stories
B3Building Class
R5Zoning
1,320 sfGross Floor Area
2Units
0 Open Violations
Two family converted from one family · 2,100 sf lot · 0.63 FAR built · Flood zone X
Locations of Work
Plumbing
Floor 21p · 1 filing · 13 docs
Floor 11p · 1 filing · 13 docs
▾Sales History (ACRIS)
DatePriceUnitSeller → Buyer$/sf
03/30/2022$999K—Private party → Private party$757/sf building
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
JOSE A. SANTOS P.E.P.C308/06/2021
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
JM ZONING, LLC.603/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
INFINITI ESC PLUMBING CORPlumbing107/08/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
JOSE A SANTOS PE, PC3292308/06/2021
Building Lifecycle
All (18)Filed (3)Permit Issued (1)Signed Off (1)Violation (5)Objection (4)Special Inspection (4)
01/14/2022
Signed off — Alteration
PROPOSE TO REPLACE PLUMBING FIXTURES AS PER PLANS SUBMITTED HEREWITH. ADDRESSING ECB VIOLATION #39025868Z & #39025869K.THERE SHALL BE NO CHANGE IN USE, OCCUPANCY OR MEANS OF EGRESS UNDER THIS APPLICATION.
Q00450693-I1
08/12/2021
Objection resolved — Addressed
08/12/2021
Special inspection requirement — Fire-Resistant Penetrations and Joints
Jose Santos
08/12/2021
Special inspection requirement — Energy Code Compliance Inspections
Jose Santos
08/06/2021
Filed — Alteration
PROPOSE TO REPLACE PLUMBING FIXTURES AS PER PLANS SUBMITTED HEREWITH. ADDRESSING ECB VIOLATION #39025868Z & #39025869K.THERE SHALL BE NO CHANGE IN USE, OCCUPANCY OR MEANS OF EGRESS UNDER THIS APPLICATION.
Q00450693-P2
08/06/2021
Objection raised — Scope
08/05/2021
Special inspection requirement — Fire-Resistant Penetrations and Joints
Jose Santos
08/05/2021
Special inspection requirement — Energy Code Compliance Inspections
Jose Santos
04/15/2021
Permit issued — Plumbing
Q00450693-I1-PL
03/30/2021
Filed — Alteration
PROPOSE TO REPLACE PLUMBING FIXTURES AS PER PLANS SUBMITTED HEREWITH. ADDRESSING ECB VIOLATION #39025868Z & #39025869K.THERE SHALL BE NO CHANGE IN USE, OCCUPANCY OR MEANS OF EGRESS UNDER THIS APPLICATION.
Q00450693-P1
01/14/2021
Objection raised — Other
01/14/2021
Objection resolved — Addressed
01/11/2021
Filed — Alteration
PROPOSE TO REPLACE PLUMBING FIXTURES AS PER PLANS SUBMITTED HEREWITH. ADDRESSING ECB VIOLATION #39025868Z & #39025869K.THERE SHALL BE NO CHANGE IN USE, OCCUPANCY OR MEANS OF EGRESS UNDER THIS APPLICATION.
Q00450693-I1
11/25/2020
Violation issued (ECB, closed)
Construction
10/14/2020
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
07/24/2020
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
07/24/2020
Violation issued (ECB, closed)
Construction
07/24/2020
Violation issued (ECB, closed)
Unknown
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWPlumbingSigned-offINFINITI ESC PLUMBING COR04/15/2021
BISOTISSUEDURENA CONST & DESIGN INC02/16/2021
1 project · most recent 03/08/2021
General Wiring
FiledStatusContractorScope
03/08/2021CompleteC.FALCO ELETL CONT CORPGeneral Wiring
▾Special Inspection Requirements (DOB NOW) — 4
DateRequirementInspectorRole
08/12/2021Fire-Resistant Penetrations and JointsJose Santosspecial
08/12/2021Energy Code Compliance InspectionsJose Santosprogress
08/05/2021Fire-Resistant Penetrations and JointsJose Santosspecial
08/05/2021Energy Code Compliance InspectionsJose Santosprogress
▾Documents — 40 on file (BIS + DOB NOW)
▸Plans & Drawings3
▸DOB NOWPlans/Sketch - Plumbing3
08/15/2026Q00450693-P2Request digital key ↗
08/15/2026Q00450693-P1Request digital key ↗
08/14/2026Q00450693-I1Request digital key ↗
▸Applications & Permits6
▸BISPLAN / WORK APPROVAL APPLICATION3
07/20/2021440652946Open ↗
02/16/2021440652946Open ↗
12/30/2020440652946Open ↗
▸BISNon-Directive 14 Construction Sign Off Including Sign Applications1
10/27/2021440652946Open ↗
▸BISPLAN - WORK & PERMITS - SUPPPORTING DOCUMENTATION1
01/12/2021440652946Open ↗
▸BISWORK PERMIT APPLICATION1
02/16/2021440652946Open ↗
▸Zoning, Tax Lot & Property Records1
▸BISRESTRICTION: RESTRICTIVE DECLARATION1
01/12/2021440652946Open ↗
▸Seals & Professional Certifications8
▸DOB NOWDPL-1: Design Professional Seal & Signature3
08/27/2026Q00450693-P2Open ↗
08/27/2026Q00450693-P1Open ↗
08/27/2026Q00450693-I1Open ↗
▸DOB NOWProgress Inspector Seal & Signature2
09/25/2026Q00450693-P2Open ↗
08/23/2026Q00450693-I1Open ↗
▸DOB NOWSpecial Inspector Seal & Signature2
09/25/2026Q00450693-P2Open ↗
08/23/2026Q00450693-I1Open ↗
▸BISAPPLICANT OWNER SIGNATURE1
02/16/2021440652946Open ↗
▸Environmental & Asbestos4
▸DOB NOWDEP ACP-5: Asbestos Assessment Report3
08/27/2026Q00450693-P1Open ↗
08/15/2026Q00450693-P2Open ↗
08/14/2026Q00450693-I1Open ↗
▸BISASBESTOS: CERTIFICATION (DEP ACP5)1
12/07/2020440652946Open ↗
▸Energy Compliance4
▸BISTECHNICAL REPORT: ENERGY CODE - RESPONSIBILITY3
10/27/2021440652946Open ↗
01/27/2021440652946Open ↗
01/21/2021440652946Open ↗
▸BISAS-BUILT ENERGY ANALYSIS1
10/27/2021440652946Open ↗
▸Inspections & Test Reports3
▸BISTECHNICAL REPORT: RESPONSIBILITY3
10/27/2021440652946Open ↗
01/26/2021440652946Open ↗
12/07/2020440652946Open ↗
▸Approvals, Objections & Sign-offs1
▸BISCERTIFICATE OF OCCUPANCY/LOC: REQUEST1
10/27/2021440652946Open ↗
▸Cost, Insurance & Ownership4
▸BISCOST AFFIDAVIT4
10/27/2021440652946Open ↗
01/25/2021440652946Open ↗
01/12/2021440652946Open ↗
Showing 3 of 4 on file for this type
▸Filing & Intake Forms6
▸BISADDITIONAL INFORMATION5
09/17/2021440652946Open ↗
08/30/2021440652946Open ↗
08/24/2021440652946Open ↗
Showing 3 of 5 on file for this type
▸BISEFILING JOB APPLICATION COVER SHEET1
02/16/2021440652946Open ↗