← Back
Factory, light manufacturing
64-15 GRAND AVENUE
QUEENS · BIN 4437560
💬 Discuss this project
1915Year Built
1Stories
F5Building Class
R5BZoning
4,450 sfGross Floor Area
1Units
13 Open Violations ▸FDNY Report ↗
Factory, light manufacturing · Owner of record: 6415 YANG'S PROPERTIES LLC · 4,630 sf lot · 0.96 FAR built · Flood zone X
Locations of Work
ArchitecturePlumbing
Roof5p · 1 filing · 11 docs
Floor 112p · 2 filings · 20 docs
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
YANG ZAU PROPERTY CORP.1703/22/2026
6415 YANG'S PROPERTIES LL303/22/2026
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
ZHENG & ASSOCIATES LLC408/03/2023
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
SPLEN CONSTRUCTION INCGeneral Contractor303/21/2026
ZAQ CONSTRUCTION INCGeneral Contractor203/21/2026
XH&RC PLBG AND HTG INCPlumbing207/08/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
ZHENG & ASSOCIATES LLC7330408/03/2023
Building Lifecycle
All (30)Filed (4)Permit Issued (4)Violation (18)Special Inspection (4)
03/31/2026
Violation issued (FDNY_NOV, closed)
11/14/2025
Violation issued (DOB, open)
V-DOB VIOLATION - ACTIVE
07/01/2025
Violation issued (ECB, open)
Boilers
01/31/2025
Violation issued (ECB, closed)
Construction
01/31/2025
Violation issued (ECB, closed)
Construction
09/23/2024
Violation issued (DOB, open)
V-DOB VIOLATION - ACTIVE
08/04/2023
Special inspection requirement — Fire-Resistant Penetrations and Joints
Jinfar Liu
08/04/2023
Special inspection requirement — Energy Code Compliance Inspections
Jinfar Liu
08/03/2023
Filed — Alteration
INSTALL NEW PLUMBING FIXTURES. RENOVATION OF EXISTING COMMERCIAL KITHCEN AND FIRE SUPPERSSION SHUT OFF VALVE IN EXISTING DELI STORE.
Q00635605-P3
07/27/2023
Permit issued — Plumbing
Q00635605-I1-PL
07/11/2023
Permit issued — General Construction
Q00628766-I1-GC-CX
06/30/2023
Violation issued (DOB, open)
V-DOB VIOLATION - ACTIVE
06/30/2023
Violation issued (DOB, open)
V-DOB VIOLATION - ACTIVE
06/20/2023
Violation issued (DOB, open)
V-DOB VIOLATION - ACTIVE
04/25/2023
Violation issued (DOB, open)
V-DOB VIOLATION - ACTIVE
12/13/2021
Filed — Alteration
INSTALL NEW PLUMBING FIXTURES. RENOVATION OF EXISTING COMMERCIAL KITHCEN AND FIRE SUPPERSSION SHUT OFF VALVE IN EXISTING DELI STORE.
Q00635605-P1
12/13/2021
Special inspection requirement — Fire-Resistant Penetrations and Joints
Jinfar Liu
12/13/2021
Special inspection requirement — Energy Code Compliance Inspections
Jinfar Liu
12/06/2021
Permit issued — Plumbing
Q00635605-I1-PL
11/29/2021
Permit issued — General Construction
Q00628766-I1-GC-CX
11/23/2021
Filed — Alteration
INTERIOR RENOVATION IN EXISTING DELI STORE WITH COMMERCIAL KITCHEN. NO ANY ENLARGEMENT INVOLVED. NO CHANGE IN USE, EGRESS AND OCCUPANCY.
Q00628766-I1
11/23/2021
Filed — Alteration
INSTALL NEW PLUMBING FIXTURES. RENOVATION OF EXISTING COMMERCIAL KITHCEN AND FIRE SUPPERSSION SHUT OFF VALVE IN EXISTING DELI STORE.
Q00635605-I1
11/08/2019
Violation issued (DOB, open)
V-DOB VIOLATION - ACTIVE
08/31/2018
Violation issued (FDNY_ORDER, closed)
04/06/2018
Violation issued (DOB, open)
V-DOB VIOLATION - ACTIVE
02/24/2017
Violation issued (DOB, open)
V-DOB VIOLATION - ACTIVE
12/13/2011
Violation issued (DOB, open)
V-DOB VIOLATION - ACTIVE
06/28/1993
Violation issued (DOB, open)
V-DOB VIOLATION - ACTIVE
08/21/1991
Violation issued (ECB, closed)
Construction
08/08/1988
Violation issued (DOB, open)
V-DOB VIOLATION - ACTIVE
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWPlumbingPermit IssuedXH&RC PLBG AND HTG INC07/27/2023
DOB NOWGeneral ConstructionPermit IssuedZAQ CONSTRUCTION INC07/11/2023
DOB NOWPlumbingPermit IssuedXH&RC PLBG AND HTG INC12/06/2021
DOB NOWGeneral ConstructionPermit IssuedSPLEN CONSTRUCTION INC11/29/2021
1 project · most recent 11/23/2021
Air Conditioning Systems Ventilation Systems
FiledStatusContractorScopeMake / Model / Capacity
11/23/2021Permit IssuedZAQ CONSTRUCTION INCAir Conditioning Systems, Ventilation Systems
Cooling
Ramsond RHDZ-36-24 36,000 BTU ×8
RHQZ-36-4X9WM 36,000 BTU ×4
Ventilation
Naks 72B3-4600-FF 4,600 CFM ×4
SF9-DB 4,360 CFM ×4
1 project · most recent 08/03/2023
Gas Water/Sanitary
FiledStatusContractorScope
08/03/2023Permit IssuedXH&RC PLBG AND HTG INCGas, Water/Sanitary
1 project · most recent 12/29/2021
General Wiring
FiledStatusContractorScope
12/29/2021Permit IssuedHI-RITE ELECTRIC CORPGeneral Wiring
▾Special Inspection Requirements (DOB NOW) — 4
DateRequirementInspectorRole
08/04/2023Fire-Resistant Penetrations and JointsJinfar Liuspecial
08/04/2023Energy Code Compliance InspectionsJinfar Liuprogress
12/13/2021Fire-Resistant Penetrations and JointsJinfar Liuspecial
12/13/2021Energy Code Compliance InspectionsJinfar Liuprogress
▾Documents — 28 on file (BIS + DOB NOW)
▸Plans & Drawings6
▸DOB NOWPlans/Sketch6
08/27/2026Q00628766-P1Request digital key ↗
08/27/2026Q00628766-I1Request digital key ↗
08/24/2026Q00635605-P1Request digital key ↗
Showing 3 of 6 on file for this type
▸Seals & Professional Certifications16
▸DOB NOWProgress Inspector Seal & Signature7
08/28/2026Q00635605-P4Open ↗
08/24/2026Q00628766-P1Open ↗
08/24/2026Q00628766-P1Open ↗
Showing 3 of 7 on file for this type
▸DOB NOWDPL-1: Design Professional Seal & Signature6
08/27/2026Q00628766-P1Open ↗
08/27/2026Q00628766-I1Open ↗
08/24/2026Q00635605-I1Open ↗
Showing 3 of 6 on file for this type
▸DOB NOWSpecial Inspector Seal & Signature3
08/28/2026Q00635605-P4Open ↗
08/24/2026Q00628766-P1Open ↗
08/24/2026Q00635605-I1Open ↗
▸Environmental & Asbestos6
▸DOB NOWDEP ACP-5: Asbestos Assessment Report6
08/27/2026Q00628766-P1Open ↗
08/27/2026Q00628766-I1Open ↗
08/24/2026Q00635605-I1Open ↗
Showing 3 of 6 on file for this type