← Back
Two family frame
64-38 228 STREET
QUEENS · BIN 4163320
💬 Discuss this project
2022Year Built
2Stories
B2Building Class
R3XZoning
3,001 sfGross Floor Area
2Units
0 Open ViolationsFDNY Report ↗
Two family frame · 4,600 sf lot · 0.65 FAR built · Flood zone X
Locations of Work
ArchitecturePlumbingFire ProtectionCivil
Floor 29p · 1 filing · 20 docs
Floor 17p · 1 filing · 20 docs
Cellar9p · 1 filing · 20 docs
▾Sales History (ACRIS)
DatePriceUnitSeller → Buyer$/sf
03/18/2021$1000K—— → —— not available
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
FLUSHING ENGINEERING SERVICE PC708/01/2024
HT ASSOCIATES212/06/2023
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
HAOTIAN & ASSOCIATES INC.903/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
L&L CONSTRUCTION DEVELOPGeneral Contractor1203/21/2026
ZR WHITESTONE INCGeneral Contractor407/08/2026
P.S.I. MECHANICALPlumbing207/08/2026
AMM GEN'L CONTRACTING.INCFire Protection107/08/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
FLUSHING ENGINEERING SERV4373708/01/2024
Building Lifecycle
All (61)Filed (9)Permit Issued (9)Signed Off (2)Violation (1)Inspection (8)Objection (2)Special Inspection (30)
08/01/2024
Filed — New Building
APPLICATION HEREWITH FILED TO PROPOSE NEW TWO-STORY BUILDING WITH CELLAR, (2) TWO-FAMILY DWELLING. OBTAIN NEW C OF O
Q00555941-A3
05/14/2024
Filed — New Building
APPLICATION HEREWITH FILED TO PROPOSE NEW TWO-STORY BUILDING WITH CELLAR, (2) TWO-FAMILY DWELLING. OBTAIN NEW C OF O
Q00555941-A1
01/17/2024
Signed off — New Building
APPLICATION HEREWITH FILED TO PROPOSE NEW TWO-STORY BUILDING WITH CELLAR, (2) TWO-FAMILY DWELLING. OBTAIN NEW C OF O
Q00555941-S1
12/06/2023
Filed — New Building
APPLICATION HEREWITH FILED TO PROPOSE NEW TWO-STORY BUILDING WITH CELLAR, (2) TWO-FAMILY DWELLING. OBTAIN NEW C OF O
Q00555941-P9
11/17/2023
Inspection — Pass-Final CND-Occupancy Inspection
Pass
View inspection ↗
11/15/2023
Signed off — Alteration
Q00549199-I1
09/19/2023
Inspection — Pass-Final CND-Occupancy Inspection
Pass
View inspection ↗
08/14/2023
Filed — New Building
APPLICATION HEREWITH FILED TO PROPOSE NEW TWO-STORY BUILDING WITH CELLAR, (2) TWO-FAMILY DWELLING. OBTAIN NEW C OF O
Q00555941-P7
08/14/2023
Filed — New Building
APPLICATION HEREWITH FILED TO PROPOSE NEW TWO-STORY BUILDING WITH CELLAR, (2) TWO-FAMILY DWELLING. OBTAIN NEW C OF O
Q00555941-P8
08/14/2023
Special inspection requirement — Permanent certificate
KY FU
08/14/2023
Special inspection requirement — Fire-Resistant Penetrations and Joints
KY FU
08/14/2023
Special inspection requirement — Structural Steel - Welding
KY FU
08/14/2023
Special inspection requirement — Insulation placement and R values
KY FU
08/14/2023
Special inspection requirement — Interior lighting power
KY FU
08/14/2023
Special inspection requirement — Protection of exposed foundation insulation
KY FU
08/14/2023
Special inspection requirement — Structural Cold-Formed Steel
KY FU
08/14/2023
Special inspection requirement — Structural Steel - High Strength Bolting
KY FU
08/14/2023
Special inspection requirement — Final
KY FU
08/14/2023
Special inspection requirement — Preliminary
KY FU
08/14/2023
Special inspection requirement — Air barrier - visual inspection
KY FU
08/14/2023
Special inspection requirement — Metering
KY FU
08/14/2023
Special inspection requirement — Fenestration areas
KY FU
08/14/2023
Special inspection requirement — Fenestration and door U-factor and product ratings
KY FU
08/14/2023
Special inspection requirement — Masonry
KY FU
08/14/2023
Special inspection requirement — Private On-Site Storm Water Disposal Systems-, and Detention Facilities, Installation
KY FU
08/14/2023
Special inspection requirement — Structural Stability – Alterations of existing buildings
KY FU
08/14/2023
Special inspection requirement — Structural Steel - Details
KY FU
08/14/2023
Special inspection requirement — Subgrade Inspections
KY FU
08/14/2023
Special inspection requirement — Energy Code Compliance Inspections
KY FU
08/14/2023
Special inspection requirement — Fire-Resistance Rated Construction
KY FU
08/14/2023
Special inspection requirement — Footing and Foundation
KY FU
08/14/2023
Special inspection requirement — Maintenance information
KY FU
08/14/2023
Special inspection requirement — HVAC-R and service water piping design and insulation
KY FU
08/14/2023
Special inspection requirement — Electrical motors and elevators
KY FU
08/14/2023
Special inspection requirement — Air barrier — testing
KY FU
08/14/2023
Special inspection requirement — Fenestration air leakage
KY FU
08/14/2023
Special inspection requirement — Concrete - Cast-In-Place
KY FU
08/14/2023
Special inspection requirement — Fire-Resistant Penetrations and Joints
KY FU
08/14/2023
Special inspection requirement — Private On-Site Storm Water Disposal Systems-, and Detention Facilities, Installation
KY FU
07/03/2023
Permit issued — Plumbing
Q00555941-S1-PL
01/30/2023
Inspection — Certified Sprinkler-SP-Piping Dry/Wet-Hydrostatic Test
Certified
View inspection ↗
01/27/2023
Inspection — Certified Sprinkler-SP-Fixtures-Finish
Certified
View inspection ↗
01/25/2023
Permit issued — General Construction
Q00555941-I1-GC-CX
01/18/2023
Inspection — Certified Sprinkler-SP-Fixtures-Finish
Certified
View inspection ↗
09/18/2022
Permit issued — Sprinklers
Q00555941-S1-EW-SP
08/18/2022
Inspection — Certified Gas-Gas-Piping-Roughing
Certified
View inspection ↗
05/31/2022
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Underground
Certified
View inspection ↗
05/18/2022
Inspection — Pass-Final House Connection
Pass
View inspection ↗
05/05/2022
Permit issued — Sprinklers
Q00555941-S1-PL
04/19/2022
Filed — New Building
APPLICATION HEREWITH FILED TO PROPOSE NEW TWO-STORY BUILDING WITH CELLAR, (2) TWO-FAMILY DWELLING. OBTAIN NEW C OF O
Q00555941-S1
04/19/2022
Permit issued — General Construction
Q00555941-I1-GC-CX
03/08/2022
Permit issued — Earth Work
Q00555941-I1-GC-CX
02/15/2022
Permit issued — Structural
Q00555941-I1-FO-EA
02/07/2022
Permit issued — Construction Fence
Q00549199-I1-FN
01/21/2022
Violation issued (ECB, closed)
Construction
01/12/2022
Filed — New Building
APPLICATION HEREWITH FILED TO PROPOSE NEW TWO-STORY BUILDING WITH CELLAR, (2) TWO-FAMILY DWELLING. OBTAIN NEW C OF O
Q00555941-P1
09/20/2021
Permit issued — Construction Fence
Q00549199-I1-FN
08/31/2021
Objection raised — 2014-AN BC 3108.3 & BC 3108.4-
08/31/2021
Objection resolved — Addressed
08/26/2021
Filed — New Building
APPLICATION HEREWITH FILED TO PROPOSE NEW TWO-STORY BUILDING WITH CELLAR, (2) TWO-FAMILY DWELLING. OBTAIN NEW C OF O
Q00555941-I1
Latest 60 of 61 events.
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWPlumbingSigned-offP.S.I. MECHANICAL07/03/2023
DOB NOWGeneral ConstructionPermit IssuedL&L CONSTRUCTION DEVELOP01/25/2023
DOB NOWSprinklersSigned-offAMM GEN'L CONTRACTING.INC09/18/2022
DOB NOWSprinklersSigned-offP.S.I. MECHANICAL05/05/2022
DOB NOWGeneral ConstructionPermit IssuedL&L CONSTRUCTION DEVELOP04/19/2022
DOB NOWEarth WorkPermit IssuedL&L CONSTRUCTION DEVELOP03/08/2022
DOB NOWStructuralSigned-offL&L CONSTRUCTION DEVELOP02/15/2022
DOB NOWConstruction FenceSigned-offZR WHITESTONE INC02/07/2022
DOB NOWConstruction FenceSigned-offZR WHITESTONE INC09/20/2021
BIS—ISSUEDL&L CONSTRUCTION DEVELOP11/10/2021
1 project · most recent 08/01/2024
Sprinkler System
FiledStatusContractorScope
08/01/2024Signed-offAMM GEN'L CONTRACTING.INCSprinkler System
1 project · most recent 08/01/2024
Gas Storm Water/Sanitary
FiledStatusContractorScope
08/01/2024Signed-offP.S.I. MECHANICALGas, Storm, Water/Sanitary
2 projects · most recent 09/12/2023
General Wiring
FiledStatusContractorScope
09/12/2023CompleteAL-LECTRIC ELECT'L CONTRGGeneral Wiring
06/01/2018CompleteKJK ELECTRIC INC1 meters, 1 new_meters
1 project · most recent 08/01/2024
Steel
FiledStatusContractorScope
08/01/2024Signed-offP.S.I. MECHANICALSteel
1 project · most recent 08/01/2024
Earthwork
FiledStatusContractorScope
08/01/2024Signed-offP.S.I. MECHANICALEarthwork
▾Field Inspections (DOB CAP) — 8
DateTypeResultReport
11/17/2023Pass-Final CND-Occupancy InspectionPassView ↗
09/19/2023Pass-Final CND-Occupancy InspectionPassView ↗
01/30/2023Certified Sprinkler-SP-Piping Dry/Wet-Hydrostatic TestCertifiedView ↗
01/27/2023Certified Sprinkler-SP-Fixtures-FinishCertifiedView ↗
01/18/2023Certified Sprinkler-SP-Fixtures-FinishCertifiedView ↗
08/18/2022Certified Gas-Gas-Piping-RoughingCertifiedView ↗
05/31/2022Certified Water and Sanitary-WS-Sanitary Piping-UndergroundCertifiedView ↗
05/18/2022Pass-Final House ConnectionPassView ↗
▾Special Inspection Requirements (DOB NOW) — 65
DateRequirementInspectorRole
08/14/2023HVAC-R and service water heating system controlsKY FUenergy_progress
08/14/2023Structural Steel - WeldingKY FUspecial
08/14/2023Subgrade InspectionsKY FUspecial
08/14/2023Energy Code Compliance InspectionsKY FUprogress
08/14/2023FinalKY FUprogress
08/14/2023Fire-Resistance Rated ConstructionKY FUprogress
08/14/2023Footing and FoundationKY FUprogress
08/14/2023PreliminaryKY FUprogress
08/14/2023Insulation placement and R valuesKY FUenergy_progress
08/14/2023Permanent certificateKY FUenergy_progress
08/14/2023Maintenance informationKY FUenergy_progress
08/14/2023HVAC-R and service water piping design and insulationKY FUenergy_progress
08/14/2023Air barrier - visual inspectionKY FUenergy_progress
08/14/2023Electrical motors and elevatorsKY FUenergy_progress
08/14/2023Air barrier — testing KY FUenergy_progress
08/14/2023MeteringKY FUenergy_progress
08/14/2023Interior lighting powerKY FUenergy_progress
08/14/2023Fenestration air leakageKY FUenergy_progress
08/14/2023Fenestration areasKY FUenergy_progress
08/14/2023Fenestration and door U-factor and product ratingsKY FUenergy_progress
08/14/2023Protection of exposed foundation insulationKY FUenergy_progress
08/14/2023Fire-Resistant Penetrations and JointsKY FUspecial
08/14/2023Private On-Site Storm Water Disposal Systems-, and Detention Facilities, InstallationKY FUspecial
08/14/2023Soil Percolation Test - Individual On-Site Private Sewage Disposal SystemsKY FUspecial
08/14/2023Sprinkler SystemsKY FUspecial
Latest 25 of 65.
▾Documents — 109 on file (BIS + DOB NOW)
▸Plans & Drawings9
▸DOB NOWPlans/Sketch9
08/27/2026Q00549199-I1Request digital key ↗
08/23/2026Q00555941-P1Request digital key ↗
08/23/2026Q00555941-P7Request digital key ↗
Showing 3 of 9 on file for this type
▸Applications & Permits7
▸BISPLAN / WORK APPROVAL APPLICATION4
01/30/2024440728063Open ↗
09/15/2023440728063Open ↗
05/25/2022440728063Open ↗
Showing 3 of 4 on file for this type
▸BISWORK PERMIT APPLICATION1
03/10/2022421791715Open ↗
▸BISBPP - Street Opening DOT Permit - BPP - Street Opening1
02/07/2024440728063Open ↗
▸BISBPP-5 - Authorization to the Department of Transportation1
05/25/2022440728063Open ↗
▸Zoning, Tax Lot & Property Records6
▸DOB NOWZD1: DOB Zoning Diagram5
08/13/2026Q00555941-A1Open ↗
08/13/2026Q00555941-P7Open ↗
08/13/2026Q00555941-P1Open ↗
Showing 3 of 5 on file for this type
▸DOB NOWHouse Number Verification: TOPO Stamp1
08/13/2026Q00555941-I1Open ↗
▸Seals & Professional Certifications31
▸DOB NOWSpecial Inspector Seal & Signature11
08/25/2026Q00555941-P8Open ↗
08/25/2026Q00555941-P7Open ↗
08/25/2026Q00555941-P7Open ↗
Showing 3 of 11 on file for this type
▸DOB NOWDPL-1: Design Professional Seal & Signature9
08/27/2026Q00549199-I1Open ↗
08/23/2026Q00555941-I1Open ↗
08/23/2026Q00555941-A3Open ↗
Showing 3 of 9 on file for this type
▸DOB NOWProgress Inspector Seal & Signature9
08/25/2026Q00555941-P8Open ↗
08/25/2026Q00555941-P8Open ↗
08/25/2026Q00555941-P7Open ↗
Showing 3 of 9 on file for this type
▸BISAPPLICANT OWNER SIGNATURE1
05/25/2022440728063Open ↗
▸BISTECHNICAL REPORT STATEMENT OF RESPONSIBILITY1
05/25/2022440728063Open ↗
▸Trade Schedules & Equipment7
▸DOB NOWDEP: Sewer Certification (Sanitary/Storm)5
08/13/2026Q00555941-P1Open ↗
08/13/2026Q00555941-A3Open ↗
08/13/2026Q00555941-A1Open ↗
Showing 3 of 5 on file for this type
▸BISELECTRIC CUT-OFF1
03/10/2022421791715Open ↗
▸BISSEWER CUT-OFF1
03/10/2022421791715Open ↗
▸Safety & Tenant Protection14
▸DOB NOWStreet Tree Checklist5
08/13/2026Q00555941-P7Open ↗
08/13/2026Q00555941-P1Open ↗
08/13/2026Q00555941-I1Open ↗
Showing 3 of 5 on file for this type
▸BISSTREET TREE CHECKLIST2
06/01/2022440728063Open ↗
05/25/2022440728063Open ↗
▸BISEXCAVATION OR DEMOLITION: 5-DAY NOTICE1
03/10/2022421791715Open ↗
▸BISDEMOLITION SUBMITTAL CERTIFICATION FORM1
03/10/2022421791715Open ↗
▸BISBPP: STREET TREES SITE PLAN1
05/25/2022440728063Open ↗
▸BISSTREET TREE SIGNOFF1
02/02/2024440728063Open ↗
▸DOB NOWStreet Trees Site Plan1
08/13/2026Q00555941-I1Open ↗
▸DOB NOWStreet Tree Sign Off1
08/13/2026Q00555941-I1Open ↗
▸DOB NOWParks Department Acknowledgment Letter for Street Trees Plan1
08/13/2026Q00555941-I1Open ↗
▸Environmental & Asbestos1
▸BISASBESTOS: CERTIFICATION (DEP ACP5)1
03/10/2022421791715Open ↗
▸Energy Compliance1
▸DOB NOWEN2: As Built Energy Analysis.1
08/13/2026Q00555941-I1Open ↗
▸Inspections & Test Reports1
▸BISBPP: FIELD INSPECTION1
02/06/2024440728063Open ↗
▸Approvals, Objections & Sign-offs8
▸BISLETTERS - SUPPORTING DOCUMENTATION4
03/10/2022421791715Open ↗
03/10/2022421791715Open ↗
03/10/2022421791715Open ↗
Showing 3 of 4 on file for this type
▸BISBPP-8 - Request Items for Builders Pavement Plan Signoff1
02/07/2024440728063Open ↗
▸BISTAP LETTER - DOM SVC : DEP-DOM1
03/10/2022421791715Open ↗
▸BISLANDMARKS APPROVAL1
03/10/2022421791715Open ↗
▸BISDPR APPROVAL FOR 1 TREE REMOVAL1
06/01/2022440728063Open ↗
▸Cost, Insurance & Ownership2
▸BISPROJECT SPECIFIC GENERAL LIABILITY INSURANCE1
03/10/2022421791715Open ↗
▸BISBPP: ENGINEERS AFFIDAVIT1
02/07/2024440728063Open ↗
▸Filing & Intake Forms6
▸BISADDITIONAL INFORMATION2
02/01/2024440728063Open ↗
10/04/2023440728063Open ↗
▸BISBOROUGH INTAKE FORM1
08/10/2021421791715Open ↗
▸BISBPP: CHECKLIST IN LIEU OF PLANS-ALT31
05/25/2022440728063Open ↗
▸BISEFILING COVER SHEET1
08/10/2021421791715Open ↗
▸BISEFILING JOB APPLICATION COVER SHEET1
05/25/2022440728063Open ↗
▸Other Documents16
▸DOB NOWLocal Law 92/94 of 2019 Sustainable Roof Zone5
08/13/2026Q00555941-A3Open ↗
08/13/2026Q00555941-P7Open ↗
08/13/2026Q00555941-P1Open ↗
Showing 3 of 5 on file for this type
▸DOB NOWSite Survey: Initial4
08/13/2026Q00555941-I1Open ↗
08/13/2026Q00555941-A1Open ↗
08/13/2026Q00555941-P7Open ↗
Showing 3 of 4 on file for this type
▸BISCURB CUT: PROVIDE EXISTING NUMBER1
06/01/2022440728063Open ↗
▸BISBPP: FINAL AS-BUILT PHOTOGRAPHS1
02/06/2024440728063Open ↗
▸BISBPP: PHOTOS-SIGNED/SEALED BY APPLICANT1
06/01/2022440728063Open ↗
▸BISBPP: AS-BUILT SIDEWALK SURVEY1
02/07/2024440728063Open ↗
▸BISBPP: GRADE STUDY1
06/01/2022440728063Open ↗
▸DOB NOWAdjoining Owners Notification1
08/13/2026Q00555941-I1Open ↗
▸DOB NOWFinal Survey1
08/13/2026Q00555941-I1Open ↗