← Back
BuildNYC
One story retail building
640 PELHAM PARKWAY SOUTH
BRONX · BIN 2049378
💬 Discuss this project
1930Year Built
1Stories
K1Building Class
C4-4Zoning
14,345 sfGross Floor Area
10Units
3 Active Violations 1 unresolved · 2 paperwork only ▸
One story retail building · Owner of record: 2185 White Plains RO · 14,710 sf lot · 0.98 FAR built · Flood zone X
Locations of Work
Names shown beside floors are taken automatically from the text of filed documents and may be incomplete or wrong.
Roof1 filing
Floor 11 filing
Site & exterior6 filings
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
GSL Enterprises2103/21/2026
2185 White Plains RD1103/21/2026
Lighthouse Properties303/21/2026
640 Pelham Food203/21/2026
Payomatic203/21/2026
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
Kaback Enterprises105/04/2026
Leder-Luis Architectural Design, PL212/11/2020
Shaaban Engineering607/07/2020
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
National Sign and Lighting1203/21/2026
Leder-Luis Architectural Design203/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
National MaintenanceSign hanger607/08/2026
Approved ElectricElectrical203/21/2026
Jeco Electrical ServiceElectrical103/21/2026
All City ElectricalElectrical103/21/2026
Kaback ServiceGeneral Contractor107/08/2026
Athens ElectricElectrical103/21/2026
Gil GlickPlumbing107/08/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
IP Concrete Testing and I6252105/04/2026
Building Lifecycle
06/10/2026
Signed off — Alteration
DIRECT REPLACEMENT OF ONE 10-TON, TWO 7.5-TON, AND ONE 5-TON AIR-COOLED ROOFTOP PACKAGED UNITS ON EXISTING ROOF CURBS. RECONNECT TO EXISTING SUPPLY/RETURN DUCT RISERS AND GAS LINES BY OTHERS. NEW CONDENSATE DRAINS TO ROOF DRAINS.
X01383341-I1
05/21/2026
Permit issued — Mechanical Systems
X01383341-I1-MS
05/04/2026
Filed — Alteration
DIRECT REPLACEMENT OF ONE 10-TON, TWO 7.5-TON, AND ONE 5-TON AIR-COOLED ROOFTOP PACKAGED UNITS ON EXISTING ROOF CURBS. RECONNECT TO EXISTING SUPPLY/RETURN DUCT RISERS AND GAS LINES BY OTHERS. NEW CONDENSATE DRAINS TO ROOF DRAINS.
X01383341-I1
04/24/2026
Special inspection requirement — Energy Code Compliance Inspections
Vance Schipani
04/24/2026
Special inspection requirement — HVAC-R and service water heating system controls
Vance Schipani
88 history events on file for this building. Sign in free to see the full history. Sign in · Create account
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOW—Kaback Service—
DOB NOW—Gil Glick—
DOB NOW—National Maintenance—
DOB NOW—National Maintenance—
DOB NOW—National Maintenance—
DOB NOW—National Maintenance—
DOB NOW—National Maintenance—
DOB NOW—National Maintenance—
BIS—Mksskr Consulting Service—
BIS—City Dimensions Construction—
BIS—Ics Builders—
BIS—Metro Mechanical—
BIS—Ics Builders—
BIS—Parker Service Industries—
BIS—Precision Plumbing Services—
BIS—Precision Plumbing Services—
BIS—Precision Plumbing Services—
BIS—Duo Plumbing & Heating—
BIS—Ashlar Mechanical—
BIS—National Maintenance—
BIS—National Maintenance—
BIS—National Maintenance—
BIS—National Maintenance—
BIS—National Maintenance—
BIS—National Maintenance—
BIS—National Maintenance—
BIS—National Maintenance—
BIS—National Maintenance—
BIS—National Maintenance—
BIS—National Maintenance—
BIS—National Maintenance—
BIS—National Maintenance—
BIS—National Maintenance—
BIS—National Maintenance—
BIS—National Maintenance—
BIS—National Maintenance—
BIS—National Maintenance—
BIS—S. Digiacomo & Son—
BIS—Duo Plumbing & Heating—
BIS—S. Digiacomo & Son—
+ 16 more permits on file
Nothing on file for this building.
Nothing on file for this building.
269 filed documents on file for this building. Sign in free to see the full history. Sign in · Create account