← Back
Two family frame
641 EAST 224 STREET
BRONX · Williamsbridge-Olinville · BIN 2062990
💬 Discuss this project
1910Year Built
2Stories
B2Building Class
R6AZoning
3,570 sfGross Floor Area
2Units
1 Open Violation ▸FDNY Report ↗
Two family frame · Owner of record: ANSARUDEEN ISLAMIC CENTER INC · 2,860 sf lot · 1.25 FAR built · Flood zone X
Locations of Work
ArchitectureMechanicalPlumbingEquipmentGeneral
Floor 13p · 1 filing · 3 docs
Filed — no permit issued17p · 2 filings · 7 docs
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
BEST LINE CONSTRUCTION1007/08/2026
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
BAYOMI ARCHITECT, PC201/30/2022
ENTHINK ENGINEERS LLC109/14/2020
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
JOSHUA ARCHITECT + PLANNER403/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
BEST LINE CONSTRUCTION COGeneral Contractor307/08/2026
APEX ELECTRIC CORPElectrical103/22/2026
Building Lifecycle
All (22)Filed (3)Permit Issued (3)Violation (1)Objection (1)Special Inspection (14)
04/19/2022
Permit issued — Construction Fence
X00396481-I1-FN
02/13/2022
Objection raised — Other
01/30/2022
Filed — Alteration
X00610873-I1
01/30/2022
Special inspection requirement — Maintenance information
07/27/2021
Filed — Alteration
X00472987-I1
04/15/2021
Permit issued — Construction Fence
X00396481-I1-FN
03/31/2021
Special inspection requirement — Fire-Resistance Rated Construction
03/31/2021
Special inspection requirement — Lighting in dwelling units
03/31/2021
Special inspection requirement — Insulation placement and R values
03/31/2021
Special inspection requirement — Maintenance information
03/31/2021
Special inspection requirement — Lighting controls
03/31/2021
Special inspection requirement — Fenestration areas
03/31/2021
Special inspection requirement — Fenestration air leakage
03/31/2021
Special inspection requirement — Energy Code Compliance Inspections
03/31/2021
Special inspection requirement — Fenestration and door U-factor and product ratings
03/31/2021
Special inspection requirement — Interior lighting power
03/04/2021
Special inspection requirement — Fire-Resistant Penetrations and Joints
03/04/2021
Special inspection requirement — Structural Stability – Alterations of existing buildings
03/04/2021
Special inspection requirement — Concrete - Precast
10/29/2020
Violation issued (ECB, open)
Construction
09/14/2020
Filed — Alteration
INSTALLATION OF TEMPORARY CONSTRUCTION FENCE AS PER PLANS. NO CHANGE IN USE, OCCUPANCY, OR EGRESS UNDER THIS APPLICATION.
X00396481-I1
09/14/2020
Permit issued — Construction Fence
X00396481-I1-FN
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWConstruction FencePermit IssuedBEST LINE CONSTRUCTION CO04/19/2022
DOB NOWConstruction FencePermit IssuedBEST LINE CONSTRUCTION CO04/15/2021
DOB NOWConstruction FencePermit IssuedBEST LINE CONSTRUCTION CO09/14/2020
BISOTISSUEDBEST LINE CONSTRUCTION CO04/19/2022
BISOTISSUEDBEST LINE CONSTRUCTION CO04/22/2021
BISOTISSUEDBEST LINE CONSTRUCTION CO07/31/2020
2 projects · most recent 01/29/2021
General Wiring
FiledStatusContractorScope
01/29/2021Permit IssuedCOLE ELECTRIC CORP.General Wiring
09/05/2019Permit IssuedAPEX ELECTRIC CORPGeneral Wiring
▾Special Inspection Requirements (DOB NOW) — 14
DateRequirementInspectorRole
01/30/2022Maintenance information—energy_progress
03/31/2021Fire-Resistance Rated Construction—progress
03/31/2021Lighting in dwelling units—energy_progress
03/31/2021Insulation placement and R values—energy_progress
03/31/2021Maintenance information—energy_progress
03/31/2021Lighting controls—energy_progress
03/31/2021Fenestration areas—energy_progress
03/31/2021Fenestration air leakage—energy_progress
03/31/2021Energy Code Compliance Inspections—progress
03/31/2021Fenestration and door U-factor and product ratings—energy_progress
03/31/2021Interior lighting power—energy_progress
03/04/2021Fire-Resistant Penetrations and Joints—special
03/04/2021Structural Stability – Alterations of existing buildings—special
03/04/2021Concrete - Precast—special
▾Documents — 22 on file (BIS + DOB NOW)
▸Plans & Drawings3
▸DOB NOWPlans/Sketch - Construction Fence1
08/26/2026X00396481-I1Request digital key ↗
▸DOB NOWPlans/Sketch1
08/24/2026X00610873-I1Request digital key ↗
▸DOB NOWPlans/Sketch - General Construction1
08/14/2026X00472987-I1Request digital key ↗
▸Applications & Permits2
▸BISPLAN / WORK APPROVAL APPLICATION1
07/29/2020240279916Open ↗
▸BISWORK PERMIT APPLICATION1
07/31/2020240279916Open ↗
▸Seals & Professional Certifications6
▸DOB NOWDPL-1: Design Professional Seal & Signature3
08/26/2026X00396481-I1Open ↗
08/24/2026X00610873-I1Open ↗
08/13/2026X00472987-I1Open ↗
▸BISREQUIRED ITEMS CHECKLIST FOR PROFESSIONAL CERTIFICATION1
07/29/2020240279916Open ↗
▸BISPROFESSIONAL CERTIFICATION STATEMENT1
07/29/2020240279916Open ↗
▸BISTECHNICAL REPORT STATEMENT OF RESPONSIBILITY1
07/29/2020240279916Open ↗
▸Safety & Tenant Protection2
▸BISTENANT PROTECTION PLAN AND NOTES1
07/29/2020240279916Open ↗
▸DOB NOWTenant Protection Plan1
08/13/2026X00396481-I1Open ↗
▸Environmental & Asbestos2
▸DOB NOWDEP ACP-5: Asbestos Assessment Report2
08/24/2026X00610873-I1Open ↗
08/13/2026X00472987-I1Open ↗
▸Energy Compliance3
▸BISTECHNICAL REPORT STATEMENT OF RESPONSIBILITY FOR ENERGY CODE PROGRESS INSPECTIONS1
07/29/2020240279916Open ↗
▸BISTECHNICAL REPORT: ENERGY CODE - RESPONSIBILITY1
07/29/2020240279916Open ↗
▸DOB NOWEN2: As Built Energy Analysis.1
08/13/2026X00472987-I1Open ↗
▸Inspections & Test Reports2
▸BISTECHNICAL REPORT: RESPONSIBILITY2
07/31/2020240279916Open ↗
07/29/2020240279916Open ↗
▸Cost, Insurance & Ownership1
▸BISCOST AFFIDAVIT1
07/29/2020240279916Open ↗
▸Filing & Intake Forms1
▸BISEFILING JOB APPLICATION COVER SHEET1
07/29/2020240279916Open ↗