| Owner | Filings | Most Recent |
|---|---|---|
| BRENNAN PROPERTY MANAGEMENT | 18 | 07/08/2026 |
| L.C.R.-LLC | 2 | 03/22/2026 |
| UNION 5TH AVE REALTY | 11 | 03/22/2026 |
| OWNER OF 641 PRESIDENT ST | 2 | 03/22/2026 |
| UNION FIFTH AVE REALTY C | 1 | 03/22/2026 |
| AWAYE REALTY MANAGEMENT | 2 | 03/21/2026 |
| Date | Price | Unit | Seller → Buyer | $/sf |
|---|---|---|---|---|
| 03/15/2018 | $7.0M | — | — → — | $673/sf building |
| Firm | Filings | Most Recent |
|---|---|---|
| FEINGOLD AND GREGORY ARCH. | 6 | 05/15/2025 |
| Representative | Filings | Most Recent |
|---|---|---|
| STONECORE LLC | 7 | 03/21/2026 |
| NOREN INTERNATIONAL | 4 | 03/21/2026 |
| Firm | Trade | Roles | Most Recent |
|---|---|---|---|
| COLGATE MAINTENANCE CORP | General Contractor | 3 | 03/21/2026 |
| PRO N.Y SOLUTIONS CORP | General Contractor | 3 | 03/21/2026 |
| SAFEPIPE PLUMBING INC | Plumbing | 1 | 07/08/2026 |
| Agency | License # | Filings | Most Recent |
|---|---|---|---|
| FEINGOLD & GREGORY ARCHIT | 979 | 2 | 02/28/2025 |
| Source | Work Type | Status | Applicant | Issued |
|---|---|---|---|---|
| DOB NOW | Mechanical Systems | Signed-off | COLGATE MAINTENANCE CORP | 09/12/2025 |
| DOB NOW | Plumbing | Signed-off | BELLEROSE PLBG & HTG | 03/14/2025 |
| DOB NOW | Mechanical Systems | Signed-off | PRO N.Y SOLUTIONS CORP | 01/14/2025 |
| BIS | OT | ISSUED | PRO N.Y SOLUTIONS CORP | 09/15/2021 |
| BIS | OT | ISSUED | PRO N.Y SOLUTIONS CORP | 09/23/2020 |
| BIS | OT | ISSUED | PRO N.Y SOLUTIONS CORP | 07/17/2020 |
| BIS | OT | ISSUED | SALIK CONSTRUCTION CO.INC | 10/13/2010 |
| BIS | FP | ISSUED | NY BUSINESS FIRE SYSTEM INC. | 08/06/2007 |
| BIS | PL | ISSUED | QMB PLUMBING & HEATING INC | 03/27/2007 |
| BIS | — | ISSUED | CATHAY CONST | 01/09/2007 |
| BIS | SP | ISSUED | CAPITOL FIRE SPKL CO,INC | 09/18/2002 |
| BIS | — | ISSUED | T 4 U INDUSTRIES INC | 08/21/2002 |
| BIS | CC | ISSUED | T 4 U INDUSTRIES INC | 02/06/2001 |
| BIS | — | ISSUED | T 4 U INDUSTRIES INC | 02/05/2001 |
| BIS | EQ | ISSUED | T 4 U INDUSTRIES INC | 02/05/2001 |
| BIS | EQ | ISSUED | T 4 U INDUSTRIES INC | 02/05/2001 |
| Filed | Status | Contractor | Scope | Make / Model / Capacity |
|---|---|---|---|---|
| 05/15/2025 | Signed-off | COLGATE MAINTENANCE CORP | Heating Systems, Others | Heating Navien NAVIEN CONDENSING WATER TUBE
HIGH CAPACITY COMBI-BOILER
NCB 240/110H 56 BTU · Water Heater ×1 Other Delta Breeze RG-C1315A 150 CFM ×3 |
| Filed | Status | Contractor | Scope |
|---|---|---|---|
| 05/15/2025 | Signed-off | SAFEPIPE PLUMBING INC | Gas, Water/Sanitary |
| Filed | Status | Contractor | Scope |
|---|---|---|---|
| 08/19/2025 | Complete | JOSEPH WEINSTEIN ELECTRIC | General Wiring |
| Date | Type | Result | Report |
|---|---|---|---|
| 06/23/2025 | Pass-Final PL - Up to 3 Requested Floors | Pass | View ↗ |
| 06/18/2025 | Pass-Final PL - Up to 3 Requested Floors | Pass | View ↗ |
| 04/26/2025 | Pass-Final PL - Up to 3 Requested Floors | Pass | View ↗ |
| 03/26/2025 | Certified Gas-Gas-Piping-Roughing | Certified | View ↗ |
| 03/26/2025 | Certified Water and Sanitary-WS-Sanitary Piping-Roughing | Certified | View ↗ |
| Date | Requirement | Inspector | Role |
|---|---|---|---|
| 03/10/2025 | Mechanical Systems | Paul Gregory | special |
| 03/10/2025 | Fire-Resistant Penetrations and Joints | Paul Gregory | special |
| 03/10/2025 | Final | Paul Gregory | progress |
| 03/10/2025 | Interior lighting power | Paul Gregory | energy_progress |
| 03/10/2025 | Lighting controls | Paul Gregory | energy_progress |
| 03/10/2025 | HVAC-R and service water heating equipment | Paul Gregory | energy_progress |
| 02/18/2025 | Fire-Resistant Penetrations and Joints | Paul Gregory | special |
| 02/18/2025 | Mechanical Systems | Paul Gregory | special |
| 02/18/2025 | Final | Paul Gregory | progress |
| 02/18/2025 | Lighting controls | Paul Gregory | energy_progress |
| 02/18/2025 | Interior lighting power | Paul Gregory | energy_progress |
| 02/18/2025 | HVAC-R and service water heating equipment | Paul Gregory | energy_progress |
| 12/05/2024 | Final | Paul Gregory | progress |