← Back
Miscellaneous educational facility
6414 BAY PARKWAY
BROOKLYN · BIN 3133705
💬 Discuss this project
1931Year Built
2Stories
W9Building Class
R6AZoning
9,306 sfGross Floor Area
1Units
3 Open Violations ▸FDNY Report ↗
Miscellaneous educational facility · Owner of record: SKY BAY 6420, LLC · 6,375 sf lot · 1.46 FAR built · Flood zone X
Locations of Work
Architecture
Roof1p · 1 filing · 6 docs
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
STILLWELL AVENUE INC103/22/2026
▾Sales History (ACRIS)
DatePriceUnitSeller → Buyer$/sf
09/02/2021$1.2M—6420 BAY PARKWAY LLC → SKY BAY 6420, LLC$129/sf building
08/23/2019$1.4M—Private party → 6420 BAY PARKWAY LLC$150/sf building
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
NYX ENGINEERING, PLLC208/08/2025
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
AGIR ELEC'L LTD. D/B/AElectrical103/22/2026
Building Lifecycle
All (59)Filed (2)Violation (16)Objection (23)Special Inspection (18)
05/04/2026
Objection resolved — Resolved
05/04/2026
Objection resolved — Resolved
03/31/2026
Objection raised — Structural
03/31/2026
Objection raised — Zoning
03/31/2026
Objection raised — Admin
03/31/2026
Objection raised — Admin
03/31/2026
Objection raised — Structural
03/31/2026
Objection raised — Zoning
03/31/2026
Objection raised — Admin
03/31/2026
Objection raised — Admin
03/25/2026
Special inspection requirement — Air barrier continuity plan testing
03/25/2026
Special inspection requirement — Electrical motors and elevators
03/25/2026
Special inspection requirement — Exterior lighting power
03/25/2026
Special inspection requirement — Protection of exposed foundation insulation
03/20/2026
Special inspection requirement — Lighting controls
03/20/2026
Special inspection requirement — Metering
11/14/2025
Violation issued (DOB, open)
V-DOB VIOLATION - ACTIVE
08/26/2025
Objection raised — Zoning
08/25/2025
Objection raised — Admin
08/25/2025
Objection raised — Fire_Protection
08/25/2025
Objection raised — Fire_Protection
08/25/2025
Objection raised — Zoning
08/25/2025
Objection raised — Scope
08/25/2025
Objection raised — Fire_Protection
08/25/2025
Objection raised — Fire_Protection
08/25/2025
Objection raised — Fire_Protection
08/25/2025
Objection raised — Structural
08/25/2025
Objection raised — Structural
08/25/2025
Objection raised — Structural
08/25/2025
Objection raised — Structural
08/08/2025
Filed — New Building
PROPOSE NEW 6-STORY MIXED USE BUILDING.
B01225389-I1
07/09/2025
Special inspection requirement — Concrete - Cast-In-Place
07/09/2025
Special inspection requirement — Fire-Resistant Penetrations and Joints
07/09/2025
Special inspection requirement — Energy Code Compliance Inspections
07/09/2025
Special inspection requirement — Fire-Resistance Rated Construction
07/09/2025
Special inspection requirement — Interior lighting power
07/09/2025
Special inspection requirement — Lighting in dwelling units
07/09/2025
Special inspection requirement — Maintenance information
06/12/2025
Special inspection requirement — Fenestration areas
06/12/2025
Special inspection requirement — Air barrier - visual inspection
06/12/2025
Special inspection requirement — Insulation placement and R values
06/12/2025
Special inspection requirement — Fenestration air leakage
06/12/2025
Special inspection requirement — Fenestration and door U-factor and product ratings
09/23/2024
Violation issued (DOB, open)
V-DOB VIOLATION - ACTIVE
06/30/2023
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
06/30/2023
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
06/20/2023
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
04/25/2023
Violation issued (DOB, open)
V-DOB VIOLATION - ACTIVE
12/09/2021
Filed — ALT-CO - New Building with Existing Elements to Remain
B00626729-I1
02/27/2019
Violation issued (ECB, closed)
Construction
03/26/2018
Violation issued (ECB, closed)
Construction
03/26/2018
Violation issued (ECB, closed)
Construction
03/26/2018
Violation issued (ECB, closed)
Construction
03/21/2018
Violation issued (ECB, closed)
Construction
04/26/2017
Violation issued (ECB, closed)
Construction
01/03/2008
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
01/06/2006
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
01/31/2005
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
02/13/2004
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
BIS—ISSUEDBINNS CNTRACTING GROUP INC.02/08/2013
BIS—ISSUEDTASLIM CONSTRUCTION INC01/17/2008
BISFBISSUEDBAYSIDE FUEL OIL CORP.12/20/1991
1 project · most recent 10/10/2019
FiledStatusContractorScope
10/10/2019CompleteAGIR ELEC'L LTD. D/B/A—
1 project · most recent 08/08/2025
FiledStatusContractorScope
08/08/2025——2 scope_items
1 project · most recent 08/08/2025
Fence
FiledStatusContractorScope
08/08/2025——Fence
▾Special Inspection Requirements (DOB NOW) — 18
DateRequirementInspectorRole
03/25/2026Air barrier continuity plan testing—energy_progress
03/25/2026Electrical motors and elevators—energy_progress
03/25/2026Exterior lighting power—energy_progress
03/25/2026Protection of exposed foundation insulation—energy_progress
03/20/2026Lighting controls—energy_progress
03/20/2026Metering—energy_progress
07/09/2025Concrete - Cast-In-Place—special
07/09/2025Fire-Resistant Penetrations and Joints—special
07/09/2025Energy Code Compliance Inspections—progress
07/09/2025Fire-Resistance Rated Construction—progress
07/09/2025Interior lighting power—energy_progress
07/09/2025Lighting in dwelling units—energy_progress
07/09/2025Maintenance information—energy_progress
06/12/2025Fenestration areas—energy_progress
06/12/2025Air barrier - visual inspection—energy_progress
06/12/2025Insulation placement and R values—energy_progress
06/12/2025Fenestration air leakage—energy_progress
06/12/2025Fenestration and door U-factor and product ratings—energy_progress
▾Documents — 47 on file (BIS + DOB NOW)
▸Plans & Drawings2
▸DOB NOWPlans/Sketch2
08/31/2026B00626729-I1Request digital key ↗
08/21/2026B01225389-I1Request digital key ↗
▸Applications & Permits6
▸BISPLAN / WORK APPROVAL APPLICATION4
01/27/2020322031662Open ↗
11/06/2014321021666Open ↗
02/21/2013320520995Open ↗
Showing 3 of 4 on file for this type
▸BISWORK PERMIT APPLICATION1
02/11/2013320520995Open ↗
▸BISCERTIFICATE OF OCCUPANCY: APPLICATION1
02/22/2013320520995Open ↗
▸Zoning, Tax Lot & Property Records4
▸DOB NOWZD1: DOB Zoning Diagram2
08/13/2026B00626729-I1Open ↗
08/13/2026B01225389-I1Open ↗
▸DOB NOWHouse Number Verification: TOPO Stamp1
08/13/2026B01225389-I1Open ↗
▸DOB NOWZoning Exhibit form (1-5)1
08/13/2026B01225389-I1Open ↗
▸Seals & Professional Certifications7
▸BISTECHNICAL REPORT: RESPONSIBILITY/CERTIFICATION4
01/27/2020322031662Open ↗
02/07/2013320520995Open ↗
07/31/2012320520995Open ↗
Showing 3 of 4 on file for this type
▸DOB NOWDPL-1: Design Professional Seal & Signature3
08/31/2026B00626729-I1Open ↗
08/21/2026B01225389-I1Open ↗
08/13/2026B01225389-I1Open ↗
▸Trade Schedules & Equipment3
▸DOB NOWDEP: Sewer Certification (Sanitary/Storm)2
08/13/2026B01225389-I1Open ↗
08/13/2026B00626729-I1Open ↗
▸BISFA - FDNY APPROVAL : FD-FAA1
05/15/2015321021666Open ↗
▸Safety & Tenant Protection5
▸BISSTREET TREE CHECKLIST3
01/27/2020322031662Open ↗
02/07/2013320520995Open ↗
07/31/2012320520995Open ↗
▸BISST-1 Street Tree Checklist1
01/18/2013320520995Open ↗
▸DOB NOWStreet Tree Checklist1
08/13/2026B01225389-I1Open ↗
▸Energy Compliance2
▸BISTECHNICAL REPORT: ENERGY CODE PROGRESS INSPS2
01/27/2020322031662Open ↗
07/31/2012320520995Open ↗
▸Approvals, Objections & Sign-offs5
▸BISADMINISTRATIVE OBJECTIONS3
11/06/2014321021666Open ↗
11/06/2014321021666Open ↗
07/31/2012320520995Open ↗
▸BISSCHEDULE A - OCCUPANCY / USE2
01/27/2020322031662Open ↗
07/31/2012320520995Open ↗
▸Cost, Insurance & Ownership3
▸BISCOST AFFIDAVIT3
01/27/2020322031662Open ↗
11/06/2014321021666Open ↗
07/31/2012320520995Open ↗
▸Filing & Intake Forms4
▸BISEFILING COVER SHEET3
01/27/2020322031662Open ↗
11/06/2014321021666Open ↗
07/31/2012320520995Open ↗
▸BISADDITIONAL INFORMATION1
05/08/2013320520995Open ↗
▸Other Documents6
▸DOB NOWLocal Law 92/94 of 2019 Sustainable Roof Zone2
08/13/2026B00626729-I1Open ↗
08/13/2026B01225389-I1Open ↗
▸DOB NOWProperty Ownership Certification2
08/31/2026B00626729-I1Open ↗
08/13/2026B01225389-I1Open ↗
▸BISPLOT DIAGRAM1
07/31/2012320520995Open ↗
▸DOB NOWSite Survey: Initial1
08/13/2026B01225389-I1Open ↗