| Owner | Filings | Most Recent |
|---|---|---|
| 3R1 GROUP | 5 | 09/21/2026 |
| Date | Price | Unit | Seller → Buyer | $/sf |
|---|---|---|---|---|
| 12/19/2024 | $300K | — | — → — | $679/sf building |
| Firm | Filings | Most Recent |
|---|---|---|
| ANTHONY CUCICH ARCHITECT | 1 | 09/14/2026 |
| PULLUMB KALEMI | 3 | 06/23/2026 |
| M JUST ARCHITECTURE PC | 2 | 06/12/2025 |
| RLM ENGINEERING PLLC | 2 | 05/29/2025 |
| Representative | Filings | Most Recent |
|---|---|---|
| JUST ARCHITECTURE | 4 | 03/21/2026 |
| Firm | Trade | Roles | Most Recent |
|---|---|---|---|
| AAG HOME IMPR INC | General Contractor | 1 | 07/01/2026 |
| CARLIN CONTRACTING OF NY | General Contractor | 1 | 07/29/2026 |
| P.S.I. MECHANICAL | Plumbing | 1 | 07/30/2026 |
| Agency | License # | Filings | Most Recent |
|---|---|---|---|
| ANTHONY CUCICH ARCHITECT | 6081 | 2 | 06/23/2026 |
| Source | Work Type | Status | Applicant | Issued |
|---|---|---|---|---|
| DOB NOW | Plumbing | Permit Issued | P.S.I. MECHANICAL | 07/29/2026 |
| DOB NOW | Foundation | Permit Issued | CARLIN CONTRACTING OF NY | 07/28/2026 |
| DOB NOW | Construction Fence | Permit Issued | AAG HOME IMPR INC | 06/29/2026 |
| Filed | Status | Contractor | Scope | Make / Model / Capacity |
|---|---|---|---|---|
| 05/29/2025 | — | — | Heating and Air Conditioning Systems, Others | Heat / Cool Daikin AC-1, AC-2, AC-6 & AC-7 Model #FXAQ07PVJU 7,500 BTU · Vrf Indoor ×4 AC-4 & AC-5 Model #FXA20AVM 2,500 BTU · Vrf Indoor ×2 #RXTQ48TAVU 4 tons · Vrf Outdoor ×1 AC-3 Model #FXAQ09PVJU 9,500 BTU · Vrf Indoor ×1 Other Captiveaire EF-1, EF-2, EF-3 Model #CFA-D50-CA 50 CFM · Exhaust Fan ×3 EF-4 Model #CFA-D110-CA 110 CFM · Kitchen Exhaust ×1 |
| Filed | Status | Contractor | Scope |
|---|---|---|---|
| 09/14/2026 | — | — | Gas, Storm, Water/Sanitary |
| 06/23/2026 | Permit Issued | P.S.I. MECHANICAL | Gas, Storm, Water/Sanitary |
| 05/29/2025 | — | — | Gas, Storm, Water/Sanitary |
| Filed | Status | Contractor | Scope |
|---|---|---|---|
| 09/07/2026 | Permit Issued | WCK ELECTRIC CORP. | General Wiring |
| Filed | Status | Contractor | Scope |
|---|---|---|---|
| 09/14/2026 | — | — | Concrete, Wood |
| 06/23/2026 | Permit Issued | P.S.I. MECHANICAL | Wood |
| 05/30/2025 | — | — | Concrete, Wood |
| Filed | Status | Contractor | Scope |
|---|---|---|---|
| 06/23/2026 | Permit Issued | P.S.I. MECHANICAL | Fence |
| 06/12/2025 | — | — | Fence |
| Date | Type | Result | Report |
|---|---|---|---|
| 07/14/2026 | Pass-Final PL - Underground | Pass | View ↗ |
| Date | Requirement | Inspector | Role |
|---|---|---|---|
| 08/28/2026 | Fire-Resistant Penetrations and Joints | — | special |
| 08/28/2026 | Concrete - Cast-In-Place | — | special |
| 08/28/2026 | Energy Code Compliance Inspections | — | progress |
| 08/28/2026 | Lowest Floor Elevation | — | progress |
| 08/28/2026 | Structural Stability – Alterations of existing buildings | — | special |
| 08/28/2026 | Final | — | progress |
| 08/28/2026 | Footing and Foundation | — | progress |
| 08/28/2026 | Permanent certificate | — | energy_progress |
| 08/28/2026 | Fenestration air leakage | — | energy_progress |
| 08/28/2026 | Interior lighting power | — | energy_progress |
| 08/28/2026 | Fenestration areas | — | energy_progress |
| 08/28/2026 | Air barrier — testing | — | energy_progress |
| 08/28/2026 | Metering | — | energy_progress |
| 08/28/2026 | Air barrier - visual inspection | — | energy_progress |
| 08/28/2026 | Insulation placement and R values | — | energy_progress |
| 08/28/2026 | Fenestration and door U-factor and product ratings | — | energy_progress |
| 06/22/2026 | Private On-Site Storm Water Disposal Systems-, and Detention Facilities, Installation | ANTHONY CUCICH | special |
| 06/22/2026 | Fire-Resistant Penetrations and Joints | ANTHONY CUCICH | special |
| 05/29/2025 | Insulation placement and R values | — | energy_progress |
| 05/29/2025 | Concrete - Cast-In-Place | — | special |
| 05/29/2025 | Masonry | — | special |
| 05/29/2025 | Subgrade Inspections | — | special |
| 05/29/2025 | Subsurface Investigations (Borings/Test Pits) | John Natoli | special |
| 05/29/2025 | Energy Code Compliance Inspections | — | progress |
| 05/29/2025 | Fire-Resistance Rated Construction | — | progress |