← Back
Over six families without stores
647 WILLOUGHBY AVENUE
BROOKLYN · Bedford-Stuyvesant (West) · BIN 3048856
💬 Discuss this project
1930Year Built
4Stories
C1Building Class
R6AZoning
—Gross Floor Area
10Units
7 Open Violations ▸FDNY Report ↗
Over six families without stores · Owner of record: 647 WILLOUGHBY AV. LLC · 3.37 FAR built · Flood zone X
Locations of Work
Mechanical
Roof1p · 1 filing · 2 docs
Floor 41p · 1 filing · 2 docs
Floor 3
Floor 21p · 1 filing · 2 docs
Floor 1
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
647 WILLOUGHBY AV. LLC203/22/2026
HPD103/21/2026
JMP PROPERTIES403/21/2026
7A ADMINSTRATOR103/21/2026
BELT PARK ASSOC203/21/2026
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
VASILIOS ARTEMIOU PE106/17/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
ANDREW MYHRE INCElectrical103/21/2026
ENGLISH, CLAUDIUSElectrical103/21/2026
FERRARO, STEVENElectrical103/21/2026
GOODE, BRIANElectrical103/21/2026
TAKOS, VASILIOS BILLYElectrical103/21/2026
Building Lifecycle
All (74)Filed (1)Violation (60)Special Inspection (13)
06/17/2026
Filed — Alteration
Proposed installation of mechanical units at a four (4) story residential use building.
B01416417-I1
06/17/2026
Special inspection requirement — HVAC-R and service water piping design and insulation
06/17/2026
Special inspection requirement — Post-installed Anchors
06/17/2026
Special inspection requirement — Tenant Protection Plan Compliance
06/17/2026
Special inspection requirement — Ventilation and air distribution system
06/17/2026
Special inspection requirement — Fire-Resistant Penetrations and Joints
06/17/2026
Special inspection requirement — Energy Code Compliance Inspections
06/17/2026
Special inspection requirement — HVAC-R and service water heating system controls
06/17/2026
Special inspection requirement — Duct leakage testing, insulation and design
06/17/2026
Special inspection requirement — HVAC-R and service water heating equipment
06/17/2026
Special inspection requirement — Maintenance information
06/17/2026
Special inspection requirement — Permanent certificate
06/12/2026
Special inspection requirement — Mechanical Systems
06/12/2026
Special inspection requirement — Final
11/14/2025
Violation issued (DOB, open)
V-DOB VIOLATION - ACTIVE
06/11/2025
Violation issued (HPD, closed)
A
11/25/2024
Violation issued (HPD, closed)
I
07/02/2024
Violation issued (HPD, closed)
B
07/02/2024
Violation issued (HPD, closed)
C
07/02/2024
Violation issued (HPD, closed)
C
07/02/2024
Violation issued (HPD, closed)
C
07/02/2024
Violation issued (HPD, closed)
B
07/02/2024
Violation issued (HPD, closed)
B
07/02/2024
Violation issued (HPD, closed)
B
04/12/2024
Violation issued (HPD, closed)
A
03/18/2024
Violation issued (HPD, open)
C
03/18/2024
Violation issued (HPD, open)
C
03/18/2024
Violation issued (HPD, closed)
C
03/18/2024
Violation issued (HPD, closed)
B
11/17/2023
Violation issued (HPD, closed)
I
06/30/2023
Violation issued (DOB, open)
V-DOB VIOLATION - ACTIVE
06/20/2023
Violation issued (DOB, open)
V-DOB VIOLATION - ACTIVE
03/27/2023
Violation issued (HPD, closed)
A
03/15/2023
Violation issued (HPD, closed)
B
03/15/2023
Violation issued (HPD, closed)
C
11/07/2022
Violation issued (HPD, closed)
I
09/08/2022
Violation issued (HPD, closed)
B
09/08/2022
Violation issued (HPD, closed)
B
09/08/2022
Violation issued (HPD, closed)
B
09/08/2022
Violation issued (HPD, closed)
B
03/21/2022
Violation issued (HPD, closed)
B
03/02/2022
Violation issued (HPD, closed)
A
09/17/2021
Violation issued (HPD, closed)
B
09/17/2021
Violation issued (HPD, closed)
B
09/17/2021
Violation issued (HPD, closed)
C
09/17/2021
Violation issued (HPD, closed)
A
09/17/2021
Violation issued (HPD, closed)
C
04/13/2021
Violation issued (HPD, closed)
A
09/16/2019
Violation issued (HPD, closed)
A
09/16/2019
Violation issued (HPD, closed)
B
09/16/2019
Violation issued (HPD, closed)
C
07/24/2019
Violation issued (HPD, closed)
C
07/24/2019
Violation issued (HPD, closed)
C
07/24/2019
Violation issued (HPD, closed)
C
07/24/2019
Violation issued (HPD, closed)
C
03/12/2019
Violation issued (HPD, closed)
C
03/12/2019
Violation issued (HPD, closed)
C
06/24/2018
Violation issued (HPD, closed)
B
03/27/2018
Violation issued (HPD, closed)
A
03/27/2018
Violation issued (HPD, closed)
A
Latest 60 of 74 events.
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
BISBLISSUEDJODOM MECHANICAL, INC04/11/2014
BISPLISSUEDJODOM MECHANICAL, INC07/29/2013
BISPLISSUEDJODOM MECHANICAL, INC07/29/2013
BISPLISSUEDJODOM MECHANICAL, INC08/02/2012
BISBLISSUEDJODOM MECHANICAL, INC08/02/2012
BISOTISSUEDGARCON INC.12/19/2007
BISPLISSUEDB & N PLUMBING & HEATING INC.07/16/2003
BISOTISSUEDST MARKS PLUMB&HEAT CO IN07/20/2000
BISFBISSUEDEAST COAST PETROLEUM12/30/1999
1 project · most recent 06/17/2026
Heating and Air Conditioning Systems
FiledStatusContractorScopeMake / Model / Capacity
06/17/2026——Heating and Air Conditioning Systems
Heat / Cool
Daikin 4MXM36AVJU9 34,200 BTU · Vrf Outdoor ×6
2MXM18AVJU9 17,200 BTU · Vrf Outdoor ×2
3MXM24AVJU9 23,000 BTU · Vrf Outdoor ×2
1 project · most recent 07/23/2025
General Wiring
FiledStatusContractorScope
07/23/2025Permit IssuedADD ELECTRICAL CONTRG INCGeneral Wiring
▾Special Inspection Requirements (DOB NOW) — 13
DateRequirementInspectorRole
06/17/2026HVAC-R and service water piping design and insulation—energy_progress
06/17/2026Post-installed Anchors—special
06/17/2026Tenant Protection Plan Compliance—special
06/17/2026Ventilation and air distribution system—energy_progress
06/17/2026Fire-Resistant Penetrations and Joints—special
06/17/2026Energy Code Compliance Inspections—progress
06/17/2026HVAC-R and service water heating system controls—energy_progress
06/17/2026Duct leakage testing, insulation and design—energy_progress
06/17/2026HVAC-R and service water heating equipment—energy_progress
06/17/2026Maintenance information—energy_progress
06/17/2026Permanent certificate—energy_progress
06/12/2026Mechanical Systems—special
06/12/2026Final—progress
▾Documents — 31 on file (BIS + DOB NOW)
▸Plans & Drawings1
▸DOB NOWPlans/Sketch1
08/16/2026B01416417-I1Request digital key ↗
▸Applications & Permits7
▸BISWORK PERMIT APPLICATION5
08/01/2013320528069Open ↗
08/01/2013320528069Open ↗
08/03/2012320528069Open ↗
Showing 3 of 5 on file for this type
▸BISPLAN / WORK APPROVAL APPLICATION2
07/19/2012320528069Open ↗
12/12/2007310068262Open ↗
▸Seals & Professional Certifications7
▸BISTECHNICAL REPORT: RESPONSIBILITY/CERTIFICATION4
08/03/2012320528069Open ↗
07/19/2012320528069Open ↗
12/27/2007310068262Open ↗
Showing 3 of 4 on file for this type
▸BISPROFESSIONAL CERTIFIED CHECKLIST1
12/12/2007310068262Open ↗
▸BISPROFESSIONAL CERTIFICATION STATEMENT FORM1
12/12/2007310068262Open ↗
▸DOB NOWDPL-1: Design Professional Seal & Signature1
08/16/2026B01416417-I1Open ↗
▸Trade Schedules & Equipment6
▸BISSELF-CERT PLUMBING NOTICE3
05/08/2015320528069Open ↗
07/22/2014320528069Open ↗
06/10/2014320528069Open ↗
▸BISSCHEDULE C - HEATING & COMBUSTION EQUIPMENT2
01/16/2014320528069Open ↗
07/19/2012320528069Open ↗
▸BISSCHEDULE B - PLUMBING1
07/19/2012320528069Open ↗
▸Environmental & Asbestos1
▸BISASBESTOS EXEMPTION CERTIFICATION LETTER1
12/12/2007310068262Open ↗
▸Energy Compliance2
▸BISTECHNICAL REPORT: ENERGY CODE PROGRESS INSPS2
08/03/2012320528069Open ↗
07/19/2012320528069Open ↗
▸Inspections & Test Reports1
▸BISNOTIF.-PROPOSED STEAM/HOT WATER INSPECTION1
07/22/2014320528069Open ↗
▸Approvals, Objections & Sign-offs4
▸BISADMINISTRATIVE OBJECTIONS2
07/19/2012320528069Open ↗
12/12/2007310068262Open ↗
▸BISCERTIFICATE OF OCCUPANCY/LOC: REQUEST1
12/27/2007310068262Open ↗
▸BISOIL TANK REMOVAL CERT : LETTER-FO1
05/08/2015320528069Open ↗
▸Cost, Insurance & Ownership2
▸BISCOST AFFIDAVIT2
07/19/2012320528069Open ↗
12/19/2007310068262Open ↗