← Back
Walk-up apt, over six families with stores
649 LENOX AVENUE
MANHATTAN · BIN 1060117
💬 Discuss this project
1920Year Built
6Stories
C7Building Class
R7-2Zoning
15,946 sfGross Floor Area
17Units
Rent Stabilized2 Open Violations ▸FISP: UNSAFE
Walk-up apt, over six families with stores · Owner of record: NYC HOUSING AUTHORITY · 4,000 sf lot · 3.99 FAR built · Flood zone X
Locations of Work
ArchitectureStructuralMechanicalPlumbing
Permit Issued — active, not yet Signed-off
RoofUnder Construction74p · 1 filing · 20 docs
Floor 6Under Construction73p · 1 filing · 20 docs
Floor 5Under Construction76p · 1 filing · 20 docs
Floor 4Under Construction69p · 1 filing · 20 docs
Floor 3Under Construction69p · 1 filing · 20 docs
Floor 2Under Construction69p · 1 filing · 20 docs
Floor 1Under Construction76p · 2 filings · 20 docs
CellarUnder Construction84p · 2 filings · 20 docs
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
NEW YORK CITY HOUSING AUTHORITY2408/26/2026
NYCHA2807/08/2026
N Y C HOUSING AUTHORITY603/22/2026
SAM CITY MASTER TENANT LLC103/21/2026
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
SLM ARCHITECTURE, P.C.1308/13/2026
WELLWORTH CONSULTING LLC109/24/2024
AK CONSULTING SERVICES, INC210/01/2020
IKRA CONSULTING LLC109/30/2020
KNF SERVICES CROP311/11/2019
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
JM ZONING, LLC.1803/21/2026
UNITED SAFETY CONSULTANTS103/21/2026
HRF SERVICES CORP603/21/2026
AK CONSULTING SERVICES603/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
MNK ENTERPRISES LLCGeneral Contractor1407/08/2026
ROMA SCAFFOLDING INCGeneral Contractor1207/08/2026
SKYWORX CONTRACTING INCGeneral Contractor807/08/2026
CEGF & G PLUMBING CORPPlumbing707/08/2026
SPRING SCAFFOLDING LLCGeneral Contractor708/13/2026
MONADNOCK GEN'L CONT INCGeneral Contractor608/26/2026
PREMIER CONSTRUCTION INCGeneral Contractor306/28/2026
BELL CONSTRUCTION SVCSGeneral Contractor307/08/2026
AMIN ELECTRICAL CORPElectrical103/22/2026
MARK REYESElectrical103/21/2026
JOSEPH SORTINOElectrical103/21/2026
EIA ELECTRIC, INCElectrical103/22/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
MILROSE CONSULTANTS LLC20031308/13/2026
Building Lifecycle
All (152)Filed (21)Permit Issued (40)Signed Off (7)Facade (FISP) (9)Violation (22)Inspection (19)Objection (4)Special Inspection (30)
08/25/2026
Permit issued — General Construction
M00882775-I1-GC
08/13/2026
Filed — Alteration
BOILER REPLACEMENT FILED IN CONJUNCTION WITH RENOVATION OF 6-STORY NYCHA MULTIPLE DWELLING THROUGHOUT. NO CHANGE TO USE, EGRESS OR OCCUPANCY.
M00882775-P5
08/12/2026
Permit issued — Sidewalk Shed
M01115700-I1-SH
08/05/2026
Filed — Alteration
BOILER REPLACEMENT FILED IN CONJUNCTION WITH RENOVATION OF 6-STORY NYCHA MULTIPLE DWELLING THROUGHOUT. NO CHANGE TO USE, EGRESS OR OCCUPANCY.
M00882775-P4
08/05/2026
Inspection — Certified Water and Sanitary-WS-Fixtures-Finish
Certified
View inspection ↗
07/27/2026
Special inspection requirement — HVAC-R and service water heating system controls
Christopher Drutjons
07/27/2026
Special inspection requirement — Shutoff dampers
Christopher Drutjons
07/27/2026
Special inspection requirement — Tenant Protection Plan Compliance
07/27/2026
Special inspection requirement — Final
Christopher Drutjons
07/27/2026
Special inspection requirement — Heating Systems
Christopher Drutjons
07/27/2026
Special inspection requirement — Post-installed Anchors
Christopher Drutjons
07/27/2026
Special inspection requirement — Mechanical Systems
Christopher Drutjons
07/27/2026
Special inspection requirement — Permanent certificate
Christopher Drutjons
07/27/2026
Special inspection requirement — HVAC-R and service water heating equipment
Christopher Drutjons
07/27/2026
Special inspection requirement — Energy Code Compliance Inspections
Christopher Drutjons
07/27/2026
Special inspection requirement — HVAC-R and service water piping design and insulation
Christopher Drutjons
07/27/2026
Special inspection requirement — Maintenance information
Christopher Drutjons
07/10/2026
Inspection — Fail-Final PL - Up to 3 Requested Floors
Fail
View inspection ↗
06/22/2026
Permit issued — General Construction
M00882775-S1-GC
06/22/2026
Inspection — Pass-Final PL - Up to 3 Requested Floors
Pass
View inspection ↗
06/18/2026
Inspection — Certified Water Pressure - WP - PL - Underground Test
Certified
View inspection ↗
06/08/2026
Special inspection requirement — Maintenance information
Christopher Drutjons
06/08/2026
Special inspection requirement — HVAC-R and service water heating equipment
Christopher Drutjons
06/08/2026
Special inspection requirement — Energy Code Compliance Inspections
Christopher Drutjons
06/08/2026
Special inspection requirement — Tenant Protection Plan Compliance
06/08/2026
Special inspection requirement — Fire-Resistant Penetrations and Joints
Christopher Drutjons
06/08/2026
Special inspection requirement — HVAC-R and service water piping design and insulation
Christopher Drutjons
06/08/2026
Special inspection requirement — Post-installed Anchors
Christopher Drutjons
06/08/2026
Special inspection requirement — Permanent certificate
Christopher Drutjons
06/08/2026
Special inspection requirement — HVAC-R and service water heating system controls
Christopher Drutjons
06/02/2026
Permit issued — General Construction
M01153468-I1-GC
05/27/2026
Permit issued — Sidewalk Shed
M01115700-I1-SH
05/26/2026
Filed — Alteration
BOILER REPLACEMENT FILED IN CONJUNCTION WITH RENOVATION OF 6-STORY NYCHA MULTIPLE DWELLING THROUGHOUT. NO CHANGE TO USE, EGRESS OR OCCUPANCY.
M00882775-P3
05/20/2026
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Underground
Certified
View inspection ↗
05/19/2026
Special inspection requirement — HVAC-R and service water heating equipment
Christopher Drutjons
05/19/2026
Special inspection requirement — HVAC-R and service water piping design and insulation
Christopher Drutjons
05/19/2026
Special inspection requirement — Maintenance information
Christopher Drutjons
05/19/2026
Special inspection requirement — Energy Code Compliance Inspections
Christopher Drutjons
05/19/2026
Special inspection requirement — Permanent certificate
Christopher Drutjons
05/19/2026
Special inspection requirement — HVAC-R and service water heating system controls
Christopher Drutjons
05/19/2026
Special inspection requirement — Fire-Resistant Penetrations and Joints
Christopher Drutjons
05/19/2026
Special inspection requirement — Post-installed Anchors
Christopher Drutjons
05/19/2026
Special inspection requirement — Tenant Protection Plan Compliance
05/01/2026
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Roughing
Certified
View inspection ↗
04/30/2026
Inspection — Certified Sprinkler-SP-Fixtures-Finish
Certified
View inspection ↗
04/29/2026
Violation issued (HPD, closed)
A
04/24/2026
Filed — Alteration
BOILER REPLACEMENT FILED IN CONJUNCTION WITH RENOVATION OF 6-STORY NYCHA MULTIPLE DWELLING THROUGHOUT. NO CHANGE TO USE, EGRESS OR OCCUPANCY.
M00882775-P2
04/22/2026
Inspection — Certified Sprinkler-SP-Piping Dry/Wet-Hydrostatic Test
Certified
View inspection ↗
04/15/2026
Permit issued — Mechanical Systems
M00882775-S3-MS
04/15/2026
Permit issued — Plumbing
M00882775-S2-PL
04/14/2026
Permit issued — Plumbing
M00882775-S5-PL
03/31/2026
Signed off — Alteration
BOILER REPLACEMENT FILED IN CONJUNCTION WITH RENOVATION OF 6-STORY NYCHA MULTIPLE DWELLING THROUGHOUT. NO CHANGE TO USE, EGRESS OR OCCUPANCY.
M00882775-S7
03/31/2026
Signed off — Alteration
BOILER REPLACEMENT FILED IN CONJUNCTION WITH RENOVATION OF 6-STORY NYCHA MULTIPLE DWELLING THROUGHOUT. NO CHANGE TO USE, EGRESS OR OCCUPANCY.
M00882775-S6
03/23/2026
Objection resolved — Addressed
03/02/2026
Permit issued — Sidewalk Shed
M01115700-I1-SH
02/24/2026
Permit issued — Plumbing
M00882775-S2-PL
02/24/2026
Inspection — Pass-Final PL - Up to 9 Requested Floors
Pass
View inspection ↗
02/05/2026
Inspection — Pass-Final PL - Up to 3 Requested Floors
Pass
View inspection ↗
01/09/2026
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Roughing
Certified
View inspection ↗
12/12/2025
Inspection — Pass-Final PL - Up to 3 Requested Floors
Pass
View inspection ↗
Latest 60 of 152 events.
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWGeneral ConstructionPermit IssuedMONADNOCK GEN'L CONT INC08/25/2026
DOB NOWSidewalk ShedPermit IssuedSPRING SCAFFOLDING LLC08/12/2026
DOB NOWGeneral ConstructionPermit IssuedPREMIER CONSTRUCTION INC06/22/2026
DOB NOWGeneral ConstructionPermit IssuedMONADNOCK GEN'L CONT INC06/02/2026
DOB NOWSidewalk ShedPermit IssuedSPRING SCAFFOLDING LLC05/27/2026
DOB NOWMechanical SystemsPermit IssuedBELL CONSTRUCTION SVCS04/15/2026
DOB NOWPlumbingPermit IssuedCEGF & G PLUMBING CORP04/15/2026
DOB NOWPlumbingPermit IssuedCEGF & G PLUMBING CORP04/14/2026
DOB NOWSidewalk ShedPermit IssuedSPRING SCAFFOLDING LLC03/02/2026
DOB NOWPlumbingPermit IssuedBELL CONST SERV INC02/24/2026
DOB NOWSuspended ScaffoldPermit IssuedPREMIER CONSTRUCTION INC11/26/2025
DOB NOWMechanical SystemsPermit IssuedBELL CONSTRUCTION SVCS11/13/2025
DOB NOWMechanical SystemsPermit IssuedBELL CONSTRUCTION SVCS10/20/2025
DOB NOWSidewalk ShedPermit IssuedSPRING SCAFFOLDING LLC09/23/2025
DOB NOWGeneral ConstructionPermit IssuedMONADNOCK GEN'L CONT INC09/09/2025
DOB NOWGeneral ConstructionPermit IssuedPREMIER CONSTRUCTION INC06/18/2025
DOB NOWBoiler EquipmentSigned-offBELL CONST SERV INC03/05/2025
DOB NOWPlumbingPermit IssuedBELL CONST SERV INC03/05/2025
DOB NOWBoiler EquipmentSigned-offBELL CONST SERV INC03/05/2025
DOB NOWPlumbingPermit IssuedBELL CONST SERV INC01/10/2025
DOB NOWGeneral ConstructionPermit IssuedMONADNOCK GEN'L CONT INC10/01/2024
DOB NOWSidewalk ShedPermit IssuedSPRING SCAFFOLDING LLC09/24/2024
DOB NOWSidewalk ShedSigned-offMNK ENTERPRISES LLC07/03/2024
DOB NOWConstruction FenceSigned-offMNK ENTERPRISES LLC07/01/2024
DOB NOWSidewalk ShedSigned-offMNK ENTERPRISES LLC02/05/2024
DOB NOWConstruction FenceSigned-offMNK ENTERPRISES LLC01/31/2024
DOB NOWSidewalk ShedSigned-offMNK ENTERPRISES LLC03/06/2023
DOB NOWConstruction FenceSigned-offMNK ENTERPRISES LLC03/03/2023
DOB NOWSidewalk ShedSigned-offSKYWORX CONTRACTING INC04/11/2022
DOB NOWConstruction FenceSigned-offSKYWORX CONTRACTING INC04/07/2022
DOB NOWSidewalk ShedSigned-offSKYWORX CONTRACTING INC10/05/2021
DOB NOWConstruction FenceSigned-offSKYWORX CONTRACTING INC10/01/2021
DOB NOWConstruction FenceSigned-offSKYWORX CONTRACTING INC10/02/2020
DOB NOWSidewalk ShedSigned-offSKYWORX CONTRACTING INC10/01/2020
DOB NOWSidewalk ShedSigned-offROMA SCAFFOLDING INC08/20/2020
DOB NOWConstruction FenceSigned-offROMA SCAFFOLDING INC11/12/2019
DOB NOWSidewalk ShedSigned-offROMA SCAFFOLDING INC08/30/2019
DOB NOWSidewalk ShedSigned-offROMA SCAFFOLDING INC02/08/2019
DOB NOWSidewalk ShedSigned-offROMA SCAFFOLDING INC02/12/2018
DOB NOWSidewalk ShedSigned-offROMA SCAFFOLDING INC01/04/2018
+ 5 more permits on file
1 project · most recent 08/13/2026
Heating and Air Conditioning Systems
FiledStatusContractorScopeMake / Model / Capacity
08/13/2026Permit IssuedMONADNOCK GEN'L CONT INCHeating and Air Conditioning Systems
Heat / Cool
Mitsubishi Electric PUY-AH24NL 24,500 BTU · Condensing Unit ×1
1 project · most recent 08/13/2026
Gas Storm Water/Sanitary
FiledStatusContractorScope
08/13/2026Permit IssuedBELL CONST SERV INCGas, Storm, Water/Sanitary
6 projects · most recent 12/20/2024
General Wiring
FiledStatusContractorScope
12/20/2024Permit IssuedGOTHAM TECHNICAL SERVICESGeneral Wiring
09/26/2024Permit IssuedTOP SHELF ELECTRIC CORP—
01/23/2023Permit IssuedAMIN ELECTRICAL CORP—
05/11/2022Permit IssuedEIA ELECTRIC, INC18 meters
09/14/2020CompleteAMIN ELECTRICAL CORP—
07/02/2019Permit IssuedUSA ELECT'L SERVICES CORP—
2 projects · most recent 09/24/2024
Sidewalk Shed
FiledStatusContractorScope
09/24/2024Permit IssuedSPRING SCAFFOLDING LLCSidewalk Shed
07/19/2019——Sidewalk Shed
1 project · most recent 11/17/2025
Suspended Scaffold (SC)
FiledStatusContractorScope
11/17/2025Permit IssuedPREMIER CONSTRUCTION INCSuspended Scaffold (SC)
▾Field Inspections (DOB CAP) — 19
DateTypeResultReport
08/05/2026Certified Water and Sanitary-WS-Fixtures-FinishCertifiedView ↗
07/10/2026Fail-Final PL - Up to 3 Requested FloorsFailView ↗
06/22/2026Pass-Final PL - Up to 3 Requested FloorsPassView ↗
06/18/2026Certified Water Pressure - WP - PL - Underground TestCertifiedView ↗
05/20/2026Certified Water and Sanitary-WS-Sanitary Piping-UndergroundCertifiedView ↗
05/01/2026Certified Water and Sanitary-WS-Sanitary Piping-RoughingCertifiedView ↗
04/30/2026Certified Sprinkler-SP-Fixtures-FinishCertifiedView ↗
04/22/2026Certified Sprinkler-SP-Piping Dry/Wet-Hydrostatic TestCertifiedView ↗
02/24/2026Pass-Final PL - Up to 9 Requested FloorsPassView ↗
02/05/2026Pass-Final PL - Up to 3 Requested FloorsPassView ↗
01/09/2026Certified Water and Sanitary-WS-Sanitary Piping-RoughingCertifiedView ↗
12/12/2025Pass-Final PL - Up to 3 Requested FloorsPassView ↗
11/03/2025Fail-Final PL - Up to 9 Requested FloorsFailView ↗
10/31/2025Pass-Final Boiler Equipment InspectionPassView ↗
09/18/2025Pass-Final PL - Up to 3 Requested FloorsPassView ↗
07/28/2025Certified Storm Drainage-ST-Piping-UndergroundCertifiedView ↗
07/28/2025Certified Water and Sanitary-WS-Sanitary Piping-UndergroundCertifiedView ↗
06/28/2025Pass-Final PL - UndergroundPassView ↗
11/12/2024Certified Sprinkler-SP-Piping Dry/Wet-Hydrostatic TestCertifiedView ↗
▾Special Inspection Requirements (DOB NOW) — 61
DateRequirementInspectorRole
07/27/2026HVAC-R and service water piping design and insulationChristopher Drutjonsenergy_progress
07/27/2026Shutoff dampersChristopher Drutjonsenergy_progress
07/27/2026FinalChristopher Drutjonsprogress
07/27/2026Heating SystemsChristopher Drutjonsspecial
07/27/2026Mechanical SystemsChristopher Drutjonsspecial
07/27/2026Permanent certificateChristopher Drutjonsenergy_progress
07/27/2026Maintenance informationChristopher Drutjonsenergy_progress
07/27/2026HVAC-R and service water heating equipmentChristopher Drutjonsenergy_progress
07/27/2026Post-installed AnchorsChristopher Drutjonsspecial
07/27/2026Tenant Protection Plan Compliance—special
07/27/2026Energy Code Compliance InspectionsChristopher Drutjonsprogress
07/27/2026HVAC-R and service water heating system controlsChristopher Drutjonsenergy_progress
06/08/2026Maintenance informationChristopher Drutjonsenergy_progress
06/08/2026HVAC-R and service water heating equipmentChristopher Drutjonsenergy_progress
06/08/2026HVAC-R and service water piping design and insulationChristopher Drutjonsenergy_progress
06/08/2026HVAC-R and service water heating system controlsChristopher Drutjonsenergy_progress
06/08/2026Permanent certificateChristopher Drutjonsenergy_progress
06/08/2026Post-installed AnchorsChristopher Drutjonsspecial
06/08/2026Fire-Resistant Penetrations and JointsChristopher Drutjonsspecial
06/08/2026Tenant Protection Plan Compliance—special
06/08/2026Energy Code Compliance InspectionsChristopher Drutjonsprogress
05/19/2026HVAC-R and service water heating equipmentChristopher Drutjonsenergy_progress
05/19/2026HVAC-R and service water heating system controlsChristopher Drutjonsenergy_progress
05/19/2026Maintenance informationChristopher Drutjonsenergy_progress
05/19/2026Fire-Resistant Penetrations and JointsChristopher Drutjonsspecial
Latest 25 of 61.
▾Documents — 162 on file (BIS + DOB NOW)
▸Plans & Drawings22
▸DOB NOWPlans/Sketch17
09/06/2026M00003632-I1Request digital key ↗
08/26/2026M01115700-I1Request digital key ↗
08/24/2026M01153468-I1Request digital key ↗
Showing 3 of 17 on file for this type
▸DOB NOWPlans/Sketch - Sidewalk Shed3
09/05/2026M00196256-I1Request digital key ↗
09/05/2026M00218162-I1Request digital key ↗
09/04/2026M00403425-I1Request digital key ↗
▸DOB NOWPlans/Sketch - Construction Fence2
09/05/2026M00262239-I1Request digital key ↗
09/04/2026M00404253-I1Request digital key ↗
▸Applications & Permits5
▸BISPLAN / WORK APPROVAL APPLICATION3
11/20/2017140704922Open ↗
07/21/2017140667151Open ↗
09/14/2016140544123Open ↗
▸BISWORK PERMIT APPLICATION2
07/21/2017140667151Open ↗
09/16/2016140544123Open ↗
▸Seals & Professional Certifications57
▸DOB NOWDPL-1: Design Professional Seal & Signature20
09/06/2026M00003632-I1Open ↗
08/24/2026M01153468-I1Open ↗
08/17/2026M00882775-S6Open ↗
Showing 3 of 20 on file for this type
▸DOB NOWProgress Inspector Seal & Signature13
09/01/2026M00882775-P4Open ↗
09/01/2026M00882775-P4Open ↗
08/28/2026M00882775-S6Open ↗
Showing 3 of 13 on file for this type
▸DOB NOWSpecial Inspector Seal & Signature10
09/02/2026M00882775-P1Open ↗
09/01/2026M00882775-P4Open ↗
08/28/2026M00882775-S6Open ↗
Showing 3 of 10 on file for this type
▸BISTECHNICAL REPORT: RESPONSIBILITY/CERTIFICATION5
02/27/2020140667151Open ↗
02/27/2020140667151Open ↗
02/12/2020140667151Open ↗
Showing 3 of 5 on file for this type
▸BISREQUIRED ITEMS CHECKLIST FOR PROFESSIONAL CERTIFICATION3
11/20/2017140704922Open ↗
07/21/2017140667151Open ↗
09/14/2016140544123Open ↗
▸BISPROFESSIONAL CERTIFICATION STATEMENT3
11/20/2017140704922Open ↗
07/21/2017140667151Open ↗
09/14/2016140544123Open ↗
▸BISTECHNICAL REPORT STATEMENT OF RESPONSIBILITY3
11/20/2017140704922Open ↗
07/21/2017140667151Open ↗
09/14/2016140544123Open ↗
▸Safety & Tenant Protection9
▸DOB NOWTenant Protection Plan5
08/13/2026M00218162-I1Open ↗
08/13/2026M00196256-I1Open ↗
08/13/2026M00262239-I1Open ↗
Showing 3 of 5 on file for this type
▸BISTENANT PROTECTION PLAN AND NOTES3
11/20/2017140704922Open ↗
07/21/2017140667151Open ↗
09/14/2016140544123Open ↗
▸DOB NOWStreet Tree Checklist1
08/13/2026M01153468-I1Open ↗
▸Environmental & Asbestos16
▸DOB NOWDEP ACP-5: Asbestos Assessment Report14
08/24/2026M01153468-I1Open ↗
08/17/2026M00882775-S6Open ↗
08/17/2026M00882775-S5Open ↗
Showing 3 of 14 on file for this type
▸BISASBESTOS: CERTIFICATION (DEP ACP5)1
07/21/2017140667151Open ↗
▸BISASBESTOS: COMPLETION OR CLOSEOUT (ACP20/21/5)1
11/20/2017140704922Open ↗
▸Energy Compliance5
▸BISTECHNICAL REPORT: ENERGY CODE - RESPONSIBILITY2
11/20/2017140704922Open ↗
11/20/2017140704922Open ↗
▸BISNYCECC ANALYSIS1
11/20/2017140704922Open ↗
▸BISELECTRICAL APPLICATION FOR SIDEWALK SHED LIGHTING1
09/14/2016140544123Open ↗
▸BISTECHNICAL REPORT STATEMENT OF RESPONSIBILITY FOR ENERGY CODE PROGRESS INSPECTIONS1
11/20/2017140704922Open ↗
▸Inspections & Test Reports4
▸BISTECHNICAL REPORT: RESPONSIBILITY2
11/20/2017140704922Open ↗
11/20/2017140704922Open ↗
▸BISDIR-14 ID OF RESPONSIBILITY (TR1)2
11/20/2017140704922Open ↗
07/21/2017140667151Open ↗
▸Approvals, Objections & Sign-offs34
▸DOB NOWFee Exempt Supporting Document - DOF ACRIS report or BIB letter20
09/06/2026M00003632-I1Open ↗
08/17/2026M00882775-S7Open ↗
08/17/2026M00882775-I1Open ↗
Showing 3 of 20 on file for this type
▸DOB NOWDesign Commission Sign Off City Owned (Exterior Work)5
08/13/2026M00403425-I1Open ↗
08/13/2026M00404253-I1Open ↗
08/13/2026M00196256-I1Open ↗
Showing 3 of 5 on file for this type
▸BISCERTIFICATE OF OCCUPANCY/LOC: REQUEST3
02/27/2020140667151Open ↗
02/12/2020140667151Open ↗
11/09/2017140544123Open ↗
▸BISLETTERS - SUPPORTING DOCUMENTATION3
02/27/2020140667151Open ↗
02/12/2020140667151Open ↗
11/09/2017140544123Open ↗
▸DOB NOWDesign Commission Approval City Owned (Exterior Work)3
08/13/2026M00262239-I1Open ↗
08/13/2026M00218162-I1Open ↗
08/13/2026M00196256-I1Open ↗
▸Cost, Insurance & Ownership1
▸BISCOST AFFIDAVIT1
11/20/2017140704922Open ↗
▸Filing & Intake Forms6
▸BISEFILING JOB APPLICATION COVER SHEET3
11/20/2017140704922Open ↗
07/21/2017140667151Open ↗
09/14/2016140544123Open ↗
▸BISBOROUGH INTAKE FORM3
02/27/2020140667151Open ↗
02/12/2020140667151Open ↗
11/09/2017140544123Open ↗
▸Other Documents3
▸DOB NOWBSA Meeting Minutes/BSA Resolution1
09/06/2026M00003632-I1Open ↗
▸DOB NOWCalculations1
08/13/2026M01319836-I1Open ↗
▸DOB NOWManufacturer's Specifications1
08/13/2026M01319836-I1Open ↗