← Back
Elevator apt, semi-fireproof with stores
65 WASHINGTON STREET
BROOKLYN · BIN 3335874
💬 Discuss this project
2000Year Built
13Stories
D7Building Class
M1-2/R8AZoning
55,677 sfGross Floor Area
59Units
LL97 CoveredRent Stabilized11 Open Violations ▸FISP: No Report FiledFDNY Report ↗
Elevator apt, semi-fireproof with stores · Owner of record: 65 WASHINGTON STREET LLC · 8,120 sf lot · 6.86 FAR built · Flood zone X500
Locations of Work
Mechanical
Permit Issued — active, not yet Signed-off
Floor 1Under Construction5p · 1 filing · 7 docs
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
TWO TREES MANAGEMENT COMPANY207/08/2026
65 WASHINGTON STREET1003/22/2026
ONE MAIN CONSTRUCTION COR1103/22/2026
OWNER OF 82 FRONT STREET103/22/2026
OWNER OF 65 WASHINGTON ST103/22/2026
ONE MAINT CONSTRUCTION PA103/22/2026
SUMMIT BANK103/22/2026
IBK CONSTRUCTION CO103/22/2026
ONWER OF 80 FRONT ST103/22/2026
65 WASHINGTON903/21/2026
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
CONCEPT DESIGN GROUP103/16/2026
PACE ENGINEERING P.C.110/02/2018
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
EUROCELT EXPEDITING, INC203/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
REPUBLIC SCAFFOLD&HOIST CGeneral Contractor903/21/2026
SPRING AIR HVAC INCGeneral Contractor207/08/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
CDG ARCHITECTS LLC /DBA:1327103/16/2026
Building Lifecycle
All (82)Filed (2)Permit Issued (5)Signed Off (1)Facade (FISP) (6)Violation (60)Inspection (2)Special Inspection (6)
07/17/2026
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Roughing
Certified
View inspection ↗
07/14/2026
Inspection — Certified Remove/Cap - work done in accordance with code
Certified
View inspection ↗
04/28/2026
Permit issued — Mechanical Systems
B01318350-I1-MS
04/08/2026
Violation issued (FDNY_NOV, closed)
03/26/2026
Permit issued — Mechanical Systems
B01318350-I1-MS
03/16/2026
Filed — Alteration
Modifications to existing HVAC system, new split systems
B01318350-I1
03/10/2026
Special inspection requirement — Tenant Protection Plan Compliance
Yongho Kim
03/10/2026
Special inspection requirement — HVAC-R and service water heating equipment
Yongho Kim
03/10/2026
Special inspection requirement — HVAC-R and service water heating system controls
Yongho Kim
03/10/2026
Special inspection requirement — HVAC-R and service water piping design and insulation
Yongho Kim
11/12/2025
Special inspection requirement — Mechanical Systems
Yongho Kim
11/12/2025
Special inspection requirement — Final
Yongho Kim
06/23/2025
Violation issued (HPD, closed)
C
02/22/2024
Violation issued (DOB, open)
V-DOB VIOLATION - ACTIVE
08/11/2023
Violation issued (HPD, closed)
A
08/11/2023
Violation issued (HPD, closed)
B
08/11/2023
Violation issued (HPD, closed)
C
08/11/2023
Violation issued (HPD, closed)
A
07/12/2023
Violation issued (ECB, closed)
Elevators
07/12/2023
Violation issued (ECB, closed)
Elevators
06/20/2023
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
06/20/2023
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
06/20/2023
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
11/05/2022
Signed off — Alteration
B00083602-I1
05/25/2021
Violation issued (DOB, closed)
V*-DOB VIOLATION - Resolved
05/25/2021
Violation issued (DOB, closed)
V*-DOB VIOLATION - Resolved
07/31/2020
Violation issued (FDNY_NOV, closed)
07/31/2020
Violation issued (FDNY_NOV, closed)
04/06/2020
Permit issued — Supported Scaffold
B00083602-I1-SF
09/24/2019
Violation issued (ECB, open)
Construction
09/06/2019
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
04/30/2019
Violation issued (DOB, open)
V-DOB VIOLATION - ACTIVE
04/01/2019
Permit issued — Supported Scaffold
B00083602-I1-SF
02/17/2019
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
10/02/2018
Filed — Alteration
B00083602-I1
10/02/2018
Permit issued — Supported Scaffold
B00083602-I1-SF
09/26/2018
Violation issued (FDNY_ORDER, closed)
04/23/2018
Violation issued (DOB, closed)
V*-DOB VIOLATION - Resolved
04/23/2018
Violation issued (DOB, closed)
V*-DOB VIOLATION - Resolved
01/26/2018
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
01/26/2018
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
03/06/2017
Violation issued (DOB, closed)
V*-DOB VIOLATION - Resolved
03/06/2017
Violation issued (DOB, closed)
V*-DOB VIOLATION - Resolved
11/14/2016
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
11/14/2016
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
04/19/2016
Violation issued (DOB, closed)
V*-DOB VIOLATION - Resolved
04/19/2016
Violation issued (DOB, closed)
V*-DOB VIOLATION - Resolved
02/16/2015
Violation issued (DOB, closed)
V*-DOB VIOLATION - Resolved
02/16/2015
Violation issued (DOB, closed)
V*-DOB VIOLATION - Resolved
12/26/2014
Cycle 7 facade report submitted
12/22/2014
Cycle 7 facade report signed — SAFE
12/17/2014
Cycle 7 facade inspection completed
05/01/2014
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
12/31/2013
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
03/11/2011
Violation issued (DOB, closed)
V*-DOB VIOLATION - Resolved
09/03/2008
Violation issued (DOB, closed)
V*-DOB VIOLATION - Resolved
09/03/2008
Violation issued (DOB, closed)
V*-DOB VIOLATION - Resolved
02/13/2008
Violation issued (DOB, closed)
V*-DOB VIOLATION - Resolved
02/13/2008
Violation issued (DOB, closed)
V*-DOB VIOLATION - Resolved
04/19/2007
Violation issued (DOB, closed)
V*-DOB VIOLATION - Resolved
Latest 60 of 82 events.
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWMechanical SystemsPermit IssuedSPRING AIR HVAC INC04/28/2026
DOB NOWMechanical SystemsPermit IssuedSPRING AIR HVAC INC03/26/2026
DOB NOWSupported ScaffoldPermit IssuedREPUBLIC SCAFFOLD&HOIST C04/06/2020
DOB NOWSupported ScaffoldPermit IssuedREPUBLIC SCAFFOLD&HOIST C04/01/2019
DOB NOWSupported ScaffoldPermit IssuedREPUBLIC SCAFFOLD&HOIST C10/02/2018
BISFPISSUEDMASTER FIRE SYSTEMS, INC08/08/2001
BISPLISSUEDMEDCO PLUMBING INC07/27/2001
BISMHISSUEDKATZ METAL FABRICATION, INC.07/27/2001
BISOTISSUEDDOUG RODGER07/03/2001
BISEQISSUEDREGIONAL SCAFFOLD HOISTING CO04/30/2001
BISEQISSUEDREGIONAL SCAFFOLD HOISTING CO01/17/2001
BISPLISSUEDMEDCO PLUMBING INC01/10/2001
BIS—RE-ISSUEDONE MAIN CONSTRUCTION11/28/2000
BISEQRE-ISSUEDONE MAIN CONSTRUCTION11/27/2000
BISEQISSUEDA R A Z INC10/23/2000
BISFPISSUEDMASTER FIRE PREVENTION SYSTEMS10/31/1991
1 project · most recent 03/16/2026
Air Conditioning Systems
FiledStatusContractorScopeMake / Model / Capacity
03/16/2026Permit IssuedSPRING AIR HVAC INCAir Conditioning Systems
Cooling
Daikin RXTA48AAVJU 45,000 BTU · Vrf Outdoor ×3
▾Field Inspections (DOB CAP) — 2
DateTypeResultReport
07/17/2026Certified Water and Sanitary-WS-Sanitary Piping-RoughingCertifiedView ↗
07/14/2026Certified Remove/Cap - work done in accordance with codeCertifiedView ↗
▾Special Inspection Requirements (DOB NOW) — 6
DateRequirementInspectorRole
03/10/2026Tenant Protection Plan ComplianceYongho Kimspecial
03/10/2026HVAC-R and service water heating equipmentYongho Kimenergy_progress
03/10/2026HVAC-R and service water heating system controlsYongho Kimenergy_progress
03/10/2026HVAC-R and service water piping design and insulationYongho Kimenergy_progress
11/12/2025Mechanical SystemsYongho Kimspecial
11/12/2025FinalYongho Kimprogress
▾Documents — 25 on file (BIS + DOB NOW)
▸Plans & Drawings2
▸DOB NOWPlans/Sketch2
09/02/2026B00083602-I1Request digital key ↗
08/18/2026B01318350-I1Request digital key ↗
▸Applications & Permits2
▸BISPLAN / WORK APPROVAL APPLICATION2
01/07/2021340758415Open ↗
12/31/2020340758415Open ↗
▸Seals & Professional Certifications7
▸DOB NOWDPL-1: Design Professional Seal & Signature2
09/02/2026B00083602-I1Open ↗
08/18/2026B01318350-I1Open ↗
▸DOB NOWProgress Inspector Seal & Signature2
09/23/2026B01318350-I1Open ↗
09/23/2026B01318350-I1Open ↗
▸BISAPPLICANT OWNER SIGNATURE1
08/27/2020340758415Open ↗
▸BISTECHNICAL REPORT STATEMENT OF RESPONSIBILITY1
11/25/2020340758415Open ↗
▸DOB NOWSpecial Inspector Seal & Signature1
09/23/2026B01318350-I1Open ↗
▸Safety & Tenant Protection1
▸BISTENANT PROTECTION PLAN AND NOTES1
08/27/2020340758415Open ↗
▸Environmental & Asbestos5
▸DOB NOWOER: Notice to Proceed2
08/13/2026B00083602-I1Open ↗
08/13/2026B01318350-I1Open ↗
▸BISENVIRONMENTAL RESTRICTIONS - OER NOTICE OF SATISFACTION1
11/25/2020340758415Open ↗
▸BISENVIRONMENTAL RESTRICTIONS - OER NOTICE TO PROCEED1
11/25/2020340758415Open ↗
▸DOB NOWOER: Notice of Satisfaction1
08/13/2026B01318350-I1Open ↗
▸Energy Compliance3
▸BISTECHNICAL REPORT: ENERGY CODE - RESPONSIBILITY2
01/07/2021340758415Open ↗
12/31/2020340758415Open ↗
▸BISTECHNICAL REPORT STATEMENT OF RESPONSIBILITY FOR ENERGY CODE PROGRESS INSPECTIONS1
11/25/2020340758415Open ↗
▸Inspections & Test Reports1
▸BISTECHNICAL REPORT: RESPONSIBILITY1
01/07/2021340758415Open ↗
▸Cost, Insurance & Ownership2
▸BISCOST AFFIDAVIT2
12/31/2020340758415Open ↗
12/31/2020340758415Open ↗
▸Filing & Intake Forms1
▸BISEFILING JOB APPLICATION COVER SHEET1
08/27/2020340758415Open ↗
▸Other Documents1
▸BISDHCR DOCUMENT1
11/25/2020340758415Open ↗