← Back
Elevator apt, fireproof with stores
651 4 AVENUE
BROOKLYN · BIN 3429696
💬 Discuss this project
2023Year Built
11Stories
D6Building Class
R8AZoning
44,160 sfGross Floor Area
28Units
0 Open ViolationsFDNY Report ↗
Elevator apt, fireproof with stores · Owner of record: 651 4TH AVE LLC · 5,487 sf lot · 8.05 FAR built · Flood zone X
Locations of Work
ArchitectureStructuralElectricalMechanicalPlumbingFire ProtectionLandscapeCivil
Permit Issued — active, not yet Signed-off
RoofUnder Construction16p · 1 filing · 10 docs
Floor 11Under Construction16p · 1 filing · 10 docs
Floor 10Under Construction16p · 1 filing · 10 docs
Floor 9Under Construction16p · 1 filing · 10 docs
Floor 8Under Construction16p · 1 filing · 10 docs
Floor 7Under Construction16p · 1 filing · 10 docs
Floor 6Under Construction283p · 2 filings · 20 docs
Floor 5Under Construction286p · 2 filings · 20 docs
Floor 4Under Construction282p · 2 filings · 20 docs
Floor 3Under Construction292p · 2 filings · 20 docs
Floor 2Under Construction293p · 2 filings · 20 docs
Floor 1Under Construction294p · 2 filings · 20 docs
CellarUnder Construction303p · 3 filings · 20 docs
1 job · most recent 02/05/2025
Air Conditioning Systems Heating Systems Ventilation Systems
FiledStatusContractorScopeMake / Model / Capacity
02/05/2025Permit IssuedNEW LEAF DEVELOPMENT LLCAir Conditioning Systems, Heating Systems, Ventilation Systems
Cooling
Lg ARUM096BTE5 96,000 BTU · Vrf Outdoor ×30
ARUN024GSS4 24,000 BTU · Vrf Outdoor ×3
ARUN038GSS4 38,000 BTU · Vrf Outdoor ×3
Heating
Lg ARUM048GSS5 48,000 BTU · Vrf Outdoor ×3
ARUM060GSS4 60,000 BTU · Vrf Outdoor ×2
ARUM072BTE5 81,000 BTU · Vrf Outdoor ×4
ARUM121BTE5 119,700 BTU · Vrf Outdoor ×3
ARUM168BTE5 168,000 BTU · Vrf Outdoor ×3
Ventilation
Greenheck AX-54-160-0418 5,150 CFM · Exhaust Fan ×3
RPBR-24-20 5,150 CFM · Exhaust Fan ×3
SP-80-VG 70 CFM · Exhaust Fan ×3
SQ-98-VG 300 CFM · Exhaust Fan ×3
Energywall U-ERV-1200 700 CFM · Erv ×3
Vts AVS020-R-FRECV,AVS020-L-FVR-CD 2,045 CFM · Erv ×3
1 job · most recent 11/20/2024
FiledStatusContractorScope
11/20/2024Permit IssuedRIGHTWAY PLBG AND HTG INC—
2 jobs · most recent 02/05/2025
Storm Water/Sanitary
FiledStatusContractorScope
02/05/2025Signed-offBEST MECHANICAL SVCS INCStorm, Water/Sanitary
01/26/2023Signed-offBEST MECHANICAL SVCS INC—
6 jobs · most recent 12/01/2023
General Wiring
FiledStatusContractorScope
12/01/2023Permit IssuedSIGMA ELECTRIC INC.General Wiring
09/06/2023Permit IssuedSIGMA ELECTRIC INC.General Wiring
04/24/2023CompleteDIFALZO ELECTRIC NY, INCGeneral Wiring
03/21/2023Permit IssuedSIGMA ELECTRIC INC.1 meters, 1 new_meters
03/14/2023CompleteSOLAS ELECTRICAL CORP—
01/30/2023CompleteSOLAS ELECTRICAL CORP—
1 job · most recent 02/05/2025
Steel Concrete
FiledStatusContractorScope
02/05/2025Signed-offBEST MECHANICAL SVCS INCSteel, Concrete
Building Lifecycle
All (238)Filed (32)Permit Issued (38)Signed Off (11)Violation (11)Inspection (36)Objection (80)Special Inspection (30)
07/30/2026
Inspection — Certified Remove/Cap - work done in accordance with code
Certified
View inspection ↗
07/30/2026
Inspection — Certified Sprinkler-SP-Piping Dry/Wet-Hydrostatic Test
Certified
View inspection ↗
06/26/2026
Permit issued — Plumbing
B00578168-S5-PL
05/07/2026
Signed off — New Building
Plumbing work per plans filed herewith.
B00578168-S6
05/07/2026
Signed off — Alteration
INSTALLATION OF TEMPORARY SUSPENDED SCAFFOLDS PER PLAN SUBMITTED. WORK SHALL COMPLY WITH 2022 BUILDING CODE CHAPTER 33. NO CHANGE IN USE, EGRESS AND/OR OCCUPANCY WITH THIS APPLICATION.
B00963712-I1
05/06/2026
Signed off — New Building
Plumbing work per plans filed herewith.
B00578168-S4
04/17/2026
Inspection — Certified Sprinkler-SP-Fixtures-Finish
Certified
View inspection ↗
04/15/2026
Inspection — Certified Sprinkler-SP-Piping Dry/Wet-Hydrostatic Test
Certified
View inspection ↗
03/24/2026
Inspection — Certified Sprinkler (SP) - Booster Pump Test
Certified
View inspection ↗
02/20/2026
Inspection — Fail-Final CND-Occupancy Inspection
Fail
View inspection ↗
02/10/2026
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Roughing
Certified
View inspection ↗
02/06/2026
Inspection — Certified Remove/Cap - work done in accordance with code
Certified
View inspection ↗
02/03/2026
Inspection — Certified Sprinkler-SP-Piping Dry/Wet-Hydrostatic Test
Certified
View inspection ↗
01/14/2026
Permit issued — Standpipe
B00601682-I1-EW-SD
01/12/2026
Inspection — Pass-Final PL - Up to 3 Requested Floors
Pass
View inspection ↗
09/23/2025
Inspection — Pass-Final CND-Occupancy Inspection
Pass
View inspection ↗
08/29/2025
Inspection — Certified Sprinkler-SP-Fixtures-Finish
Certified
View inspection ↗
08/15/2025
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Roughing
Certified
View inspection ↗
07/01/2025
Permit issued — Sprinklers
B00601682-I1-EW-SP
07/01/2025
Permit issued — Standpipe
B00819023-I1-EW-SD
05/07/2025
Signed off — Alteration
INSTALLATION OF PIPE SCAFFOLD AS PER PLANS IN COMPLIANCE WITH CHAPTER 33 OF NYC BC, NO CHANGE IN USE, EGRES, OR OCCUPANCY.
B00989346-I1
04/17/2025
Signed off — New Building
Plumbing work per plans filed herewith.
B00578168-S3
04/01/2025
Signed off — Alteration
INSTALLATION AND USE OF CONSTRUCTION FENCE AS PER PLANS SUBMITTED. CONSTRUCTION FENCE SHALL COMPLY WITH CHAPTER #33 OF NYC BUILDING CODE. THIS APPLICATION INVOLVES NO CHANGE IN OCCUPANCY, USE OR EGRESS.
B00795586-I1
03/31/2025
Permit issued — General Construction
B00578168-I1-GC
03/28/2025
Permit issued — Plumbing
B00578168-S5-PL
03/19/2025
Inspection — Certified Storm Drainage-ST-Fixtures-Finish
Certified
View inspection ↗
03/19/2025
Inspection — Certified Water and Sanitary-WS-Fixtures-Finish
Certified
View inspection ↗
03/05/2025
Inspection — Certified StandPipe - SD - Hydrostatic 63/09 Test (100 Foot Increments)
Certified
View inspection ↗
03/04/2025
Inspection — Pass-Final CND-Occupancy Inspection
Pass
View inspection ↗
02/27/2025
Signed off — Alteration
INSTALLATION OF TEMPORARY SIDEWALK SHED AS PER PLANS. NO CHANGE IN USE, EGRESS OR OCCUPANCY.
B00817169-I1
02/27/2025
Signed off — Alteration
INSTALLATION OF TEMPORARY OVERHEAD PROTECTION AS PER PLANS. NO CHANGE IN USE, EGRESS OR OCCUPANCY.
B00817172-I1
02/27/2025
Signed off — Alteration
B00870904-I1
02/26/2025
Violation issued (FDNY_ORDER, closed)
02/26/2025
Violation issued (FDNY_ORDER, closed)
02/26/2025
Inspection — Fail-Final PL - Up to 3 Requested Floors
Fail
View inspection ↗
02/05/2025
Filed — New Building
Plumbing work per plans filed herewith.
B00578168-A6
01/03/2025
Inspection — Pass-Final CND-Occupancy Inspection
Pass
View inspection ↗
12/30/2024
Permit issued — General Construction
B00578168-I1-GC
12/19/2024
Inspection — Certified StandPipe-Fire Pump (SD)-Fire Pump Test
Certified
View inspection ↗
12/16/2024
Inspection — Certified StandPipe-SD-Piping-Hydrostatic Test
Certified
View inspection ↗
12/13/2024
Inspection — Certified StandPipe-SD-Fixtures-Finish-SD
Certified
View inspection ↗
12/09/2024
Inspection — Certified Sprinkler-SP-Piping Dry/Wet-Hydrostatic Test
Certified
View inspection ↗
12/06/2024
Permit issued — Sprinklers
B00601682-I1-EW-SD
12/06/2024
Inspection — Certified Sprinkler-SP-Fixtures-Finish
Certified
View inspection ↗
12/06/2024
Special inspection requirement — Air barrier — testing
RONALD GRAPIN
12/06/2024
Special inspection requirement — Lighting in dwelling units
RONALD GRAPIN
12/06/2024
Special inspection requirement — Metering
RONALD GRAPIN
12/06/2024
Special inspection requirement — Fenestration and door U-factor and product ratings
RONALD GRAPIN
12/06/2024
Special inspection requirement — Fenestration areas
RONALD GRAPIN
12/06/2024
Special inspection requirement — Electrical motors and elevators
RONALD GRAPIN
12/06/2024
Special inspection requirement — Fenestration air leakage
RONALD GRAPIN
12/06/2024
Special inspection requirement — Insulation placement and R values
RONALD GRAPIN
12/06/2024
Special inspection requirement — Vestibules
RONALD GRAPIN
12/06/2024
Special inspection requirement — Exterior lighting power
RONALD GRAPIN
12/06/2024
Special inspection requirement — Lighting controls
RONALD GRAPIN
12/06/2024
Special inspection requirement — Protection of exposed foundation insulation
RONALD GRAPIN
12/06/2024
Special inspection requirement — Interior lighting power
RONALD GRAPIN
12/06/2024
Special inspection requirement — Air barrier continuity plan testing
RONALD GRAPIN
12/06/2024
Special inspection requirement — Exterior Insulation and Finish Systems (EIFS)
RONALD GRAPIN
12/06/2024
Special inspection requirement — Maintenance information
RONALD GRAPIN
Latest 60 of 238 events.
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
651 4TH AVENUE11207/08/2026
OWNERS REP1107/08/2026
DORIA407/08/2026
WINTREND LLC103/22/2026
NEW LEAF DEVELOPMENT LLC703/22/2026
CORE SCAFFOLD SYSTEMS103/22/2026
▾Sales History (ACRIS)
DatePriceUnitSeller → Buyer$/sf
03/29/2017$6.2M—— → —— not available
▾Design Consultants (Architect / Engineer of Record)
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
JM ZONING, LLC.4603/21/2026
AE DESIGN SOLUTION803/21/2026
HM LOKE CONSULTING ENGINEERING PC103/21/2026
CELTIC SERVICES NYC203/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
NEW LEAF DEVELOPMENT LLCGeneral Contractor3207/08/2026
BEST MECHANICAL SVCS INCPlumbing1207/08/2026
CORE SCAFFOLD SYSTEMS INC.General Contractor607/08/2026
CELTIC SERVICES NYC INCGeneral Contractor407/08/2026
RIGHTWAY PLBG AND HTG INCFire Protection307/08/2026
DYNAMIX SCAFFOLD GROUP LLGeneral Contractor203/21/2026
SOLAS ELECTRICAL CORPElectrical103/22/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
ATLAS ATC ENGINEERING INC80111811/20/2024
SKYLINE RIGGING7880111/17/2023
CONCRETE SOLUTIONS LAB CO5344111/01/2021
ANCORA ENGINEERING, PLLC6818110/08/2021
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWPlumbingSigned-offBEST MECHANICAL SVCS INC06/26/2026
DOB NOWStandpipePermit IssuedBEST MECHANICAL SVCS INC01/14/2026
DOB NOWSprinklersPermit IssuedRIGHTWAY PLBG AND HTG INC07/01/2025
DOB NOWStandpipeSigned-offBEST MECHANICAL SVCS INC07/01/2025
DOB NOWGeneral ConstructionPermit IssuedNEW LEAF DEVELOPMENT LLC03/31/2025
DOB NOWPlumbingSigned-offBEST MECHANICAL SVCS INC03/28/2025
DOB NOWGeneral ConstructionPermit IssuedNEW LEAF DEVELOPMENT LLC12/30/2024
DOB NOWSprinklersPermit IssuedBEST MECHANICAL SVCS INC12/06/2024
DOB NOWSupport of ExcavationSigned-offNEW LEAF DEVELOPMENT LLC11/25/2024
DOB NOWGeneral ConstructionPermit IssuedNEW LEAF DEVELOPMENT LLC11/08/2024
DOB NOWGeneral ConstructionPermit IssuedNEW LEAF DEVELOPMENT LLC08/28/2024
DOB NOWConstruction FenceSigned-offNEW LEAF DEVELOPMENT LLC07/23/2024
DOB NOWStandpipeSigned-offBEST MECHANICAL SVCS INC06/28/2024
DOB NOWSprinklersPermit IssuedRIGHTWAY PLBG AND HTG INC05/08/2024
DOB NOWProtection and Mechanical MethodsSigned-offCORE SCAFFOLD SYSTEMS INC04/30/2024
DOB NOWGeneral ConstructionPermit IssuedNEW LEAF DEVELOPMENT LLC04/11/2024
DOB NOWPlumbingSigned-offBEST MECHANICAL SVCS INC02/06/2024
DOB NOWSidewalk ShedSigned-offCORE SCAFFOLD SYSTEMS INC01/30/2024
DOB NOWMechanical SystemsSigned-offNEW LEAF DEVELOPMENT LLC01/23/2024
DOB NOWSupported ScaffoldSigned-offDYNAMIX SCAFFOLD GROUP LL01/19/2024
DOB NOWProtection and Mechanical MethodsSigned-offCORE SCAFFOLD SYSTEMS INC01/12/2024
DOB NOWGeneral ConstructionPermit IssuedNEW LEAF DEVELOPMENT LLC12/18/2023
DOB NOWSuspended ScaffoldPermit IssuedDORIA, INC11/20/2023
DOB NOWConstruction FenceSigned-offNEW LEAF DEVELOPMENT LLC07/29/2023
DOB NOWStandpipeSigned-offBEST MECHANICAL SVCS INC06/21/2023
DOB NOWStructuralSigned-offNEW LEAF DEVELOPMENT LLC05/11/2023
DOB NOWProtection and Mechanical MethodsSigned-offCORE SCAFFOLD SYSTEMS INC05/09/2023
DOB NOWSprinklersPermit IssuedRIGHTWAY PLBG AND HTG INC03/09/2023
DOB NOWStructuralSigned-offNEW LEAF DEVELOPMENT LLC03/01/2023
DOB NOWMechanical SystemsSigned-offNEW LEAF DEVELOPMENT LLC02/21/2023
DOB NOWPlumbingSigned-offBEST MECHANICAL SVCS INC02/21/2023
DOB NOWFoundationSigned-offNEW LEAF DEVELOPMENT LLC02/17/2023
DOB NOWSidewalk ShedSigned-offCORE SCAFFOLD SYSTEMS INC02/07/2023
DOB NOWGeneral ConstructionPermit IssuedNEW LEAF DEVELOPMENT LLC02/01/2023
DOB NOWProtection and Mechanical MethodsSigned-offCORE SCAFFOLD SYSTEMS INC01/24/2023
DOB NOWConstruction FenceSigned-offNEW LEAF DEVELOPMENT LLC08/22/2022
DOB NOWConstruction FenceSigned-offCELTIC SERVICES NYC INC05/27/2022
DOB NOWConstruction FenceSigned-offCELTIC SERVICES NYC INC08/10/2021
▾Field Inspections (DOB CAP) — 36
DateTypeResultReport
07/30/2026Certified Remove/Cap - work done in accordance with codeCertifiedView ↗
07/30/2026Certified Sprinkler-SP-Piping Dry/Wet-Hydrostatic TestCertifiedView ↗
04/17/2026Certified Sprinkler-SP-Fixtures-FinishCertifiedView ↗
04/15/2026Certified Sprinkler-SP-Piping Dry/Wet-Hydrostatic TestCertifiedView ↗
03/24/2026Certified Sprinkler (SP) - Booster Pump TestCertifiedView ↗
02/20/2026Fail-Final CND-Occupancy InspectionFailView ↗
02/10/2026Certified Water and Sanitary-WS-Sanitary Piping-RoughingCertifiedView ↗
02/06/2026Certified Remove/Cap - work done in accordance with codeCertifiedView ↗
02/03/2026Certified Sprinkler-SP-Piping Dry/Wet-Hydrostatic TestCertifiedView ↗
01/12/2026Pass-Final PL - Up to 3 Requested FloorsPassView ↗
09/23/2025Pass-Final CND-Occupancy InspectionPassView ↗
08/29/2025Certified Sprinkler-SP-Fixtures-FinishCertifiedView ↗
08/15/2025Certified Water and Sanitary-WS-Sanitary Piping-RoughingCertifiedView ↗
03/19/2025Certified Storm Drainage-ST-Fixtures-FinishCertifiedView ↗
03/19/2025Certified Water and Sanitary-WS-Fixtures-FinishCertifiedView ↗
03/05/2025Certified StandPipe - SD - Hydrostatic 63/09 Test (100 Foot Increments)CertifiedView ↗
03/04/2025Pass-Final CND-Occupancy InspectionPassView ↗
02/26/2025Fail-Final PL - Up to 3 Requested FloorsFailView ↗
01/03/2025Pass-Final CND-Occupancy InspectionPassView ↗
12/19/2024Certified StandPipe-Fire Pump (SD)-Fire Pump TestCertifiedView ↗
12/16/2024Certified StandPipe-SD-Piping-Hydrostatic TestCertifiedView ↗
12/13/2024Certified StandPipe-SD-Fixtures-Finish-SDCertifiedView ↗
12/09/2024Certified Sprinkler-SP-Piping Dry/Wet-Hydrostatic TestCertifiedView ↗
12/06/2024Certified Sprinkler-SP-Fixtures-FinishCertifiedView ↗
09/13/2024Certified Water and Sanitary-WS-Sanitary Piping-UndergroundCertifiedView ↗
Latest 25 of 36.
▾Special Inspection Requirements (DOB NOW) — 150
DateRequirementInspectorRole
12/06/2024Lighting controlsRONALD GRAPINenergy_progress
12/06/2024Protection of exposed foundation insulationRONALD GRAPINenergy_progress
12/06/2024Air barrier - visual inspectionRONALD GRAPINenergy_progress
12/06/2024Energy Code Compliance InspectionsRONALD GRAPINprogress
12/06/2024Fire-Resistance Rated ConstructionRONALD GRAPINprogress
12/06/2024Fire-Resistant Penetrations and JointsRONALD GRAPINspecial
12/06/2024Exterior Insulation and Finish Systems (EIFS)RONALD GRAPINspecial
12/06/2024Wall Panels, Curtain Walls, and VeneersRONALD GRAPINspecial
12/06/2024MasonryGIORGI KHARDZEISHVILIspecial
12/06/2024Exterior lighting powerRONALD GRAPINenergy_progress
12/06/2024Interior lighting powerRONALD GRAPINenergy_progress
12/06/2024VestibulesRONALD GRAPINenergy_progress
12/06/2024Insulation placement and R valuesRONALD GRAPINenergy_progress
12/06/2024Fenestration air leakageRONALD GRAPINenergy_progress
12/06/2024Fenestration areasRONALD GRAPINenergy_progress
12/06/2024Electrical motors and elevatorsRONALD GRAPINenergy_progress
12/06/2024Lighting in dwelling unitsRONALD GRAPINenergy_progress
12/06/2024Air barrier continuity plan testingRONALD GRAPINenergy_progress
12/06/2024Maintenance informationRONALD GRAPINenergy_progress
12/06/2024MeteringRONALD GRAPINenergy_progress
12/06/2024Air barrier — testing RONALD GRAPINenergy_progress
12/06/2024Fenestration and door U-factor and product ratingsRONALD GRAPINenergy_progress
12/02/2024Standpipe SystemsRONALD GRAPINspecial
12/02/2024Fire-Resistant Penetrations and JointsRONALD GRAPINspecial
12/02/2024Sprinkler SystemsRONALD GRAPINspecial
Latest 25 of 150.
▾Documents — 330 on file (BIS + DOB NOW)
▸Plans & Drawings32
▸DOB NOWPlans/Sketch32
09/01/2026B00565084-I1Request digital key ↗
08/28/2026B00795586-I1Request digital key ↗
08/27/2026B00817172-I1Request digital key ↗
Showing 3 of 32 on file for this type
▸Applications & Permits21
▸BISPLAN / WORK APPROVAL APPLICATION18
11/26/2024340821837Open ↗
09/18/2024321705776Open ↗
09/18/2024321705767Open ↗
Showing 3 of 18 on file for this type
▸BISBPP-5 - Authorization to the Department of Transportation2
01/25/2024340821837Open ↗
09/16/2021340821837Open ↗
▸BISPLAN - WORK & PERMITS - SUPPPORTING DOCUMENTATION1
11/20/2017321686118Open ↗
▸Zoning, Tax Lot & Property Records17
▸DOB NOWZD1: DOB Zoning Diagram6
08/15/2026B00578168-I1Open ↗
Showing 1 of 6 on file for this type
▸DOB NOWZoning Exhibit form (1-5)6
08/15/2026B00578168-I1Open ↗
Showing 1 of 6 on file for this type
▸BISZONING EXHIBIT I: CERTIFICATION1
08/12/2024322117623Open ↗
▸BISTAX LOT: TENTATIVE LOT NUMBER ISSUED1
08/12/2024322117623Open ↗
▸BISZONING EXHIBIT III:DESC. & OWNRSHP.STMNT1
08/12/2024322117623Open ↗
▸BISADDRESS: NEW HOUSE NUMBER APPROVED1
11/20/2017321686118Open ↗
▸DOB NOWHouse Number Verification: TOPO Stamp1
On file, but not among the 200 most recently loaded documents for this source.
Showing 0 of 1 on file for this type
▸Seals & Professional Certifications163
▸DOB NOWProgress Inspector Seal & Signature85
09/07/2026B00578168-P3Open ↗
09/07/2026B00578168-P3Open ↗
09/01/2026B00578168-P8Open ↗
Showing 3 of 85 on file for this type
▸DOB NOWSpecial Inspector Seal & Signature36
09/29/2026B00578168-S2Open ↗
09/23/2026B00819023-I1Open ↗
09/07/2026B00578168-P3Open ↗
Showing 3 of 36 on file for this type
▸DOB NOWDPL-1: Design Professional Seal & Signature32
09/01/2026B00565084-I1Open ↗
08/28/2026B00795586-I1Open ↗
08/27/2026B00817169-I1Open ↗
Showing 3 of 32 on file for this type
▸BISTECHNICAL REPORT: RESPONSIBILITY/CERTIFICATION4
11/29/2017321686118Open ↗
11/22/2017321686118Open ↗
07/08/2014320941834Open ↗
Showing 3 of 4 on file for this type
▸BISPROFESSIONAL CERTIFICATION STATEMENT2
07/08/2014320941834Open ↗
07/08/2014320941825Open ↗
▸BISPROFESSIONAL CERTIFIED CHECKLIST2
07/08/2014320941834Open ↗
07/08/2014320941825Open ↗
▸BISAPPLICANT OWNER SIGNATURE1
09/16/2021340821837Open ↗
▸BISTECHNICAL REPORT STATEMENT OF RESPONSIBILITY1
09/16/2021340821837Open ↗
▸Trade Schedules & Equipment9
▸DOB NOWDEP: Sewer Certification (Sanitary/Storm)6
08/15/2026B00578168-I1Open ↗
Showing 1 of 6 on file for this type
▸BISSCHEDULE B - PLUMBING/SPRINKLER/STANDPIPE2
11/29/2017321686118Open ↗
11/22/2017321686118Open ↗
▸DOB NOWStandpipe Alarms Drawings1
08/15/2026B00578168-I1—
▸Safety & Tenant Protection9
▸DOB NOWStreet Tree Checklist6
08/25/2026B00578168-P2Open ↗
08/25/2026B00578168-P9Open ↗
08/25/2026B00578168-P1Open ↗
Showing 3 of 6 on file for this type
▸BISBPP: STREET TREES SITE PLAN1
01/25/2024340821837Open ↗
▸BISSTREET TREE CHECKLIST1
09/16/2021340821837Open ↗
▸DOB NOWParks Department Acknowledgment Letter for Street Trees Plan1
On file, but not among the 200 most recently loaded documents for this source.
Showing 0 of 1 on file for this type
▸Environmental & Asbestos21
▸DOB NOWOER: Notice to Proceed15
08/25/2026B00578168-S4Open ↗
08/15/2026B00578168-I1Open ↗
Showing 2 of 15 on file for this type
▸DOB NOWOER: Notice of Satisfaction5
08/15/2026B00578168-S6Open ↗
Showing 1 of 5 on file for this type
▸BISENVIRONMENTAL RESTRICTIONS - OER NOTICE TO PROCEED1
01/25/2024340821837Open ↗
▸Energy Compliance4
▸DOB NOWEN2: As Built Energy Analysis.2
On file, but not among the 200 most recently loaded documents for this source.
Showing 0 of 2 on file for this type
▸BISTECHNICAL REPORT: ENERGY CODE PROGRESS INSPS1
11/22/2017321686118Open ↗
▸DOB NOWPreliminary Commissioning Report Certification1
On file, but not among the 200 most recently loaded documents for this source.
Showing 0 of 1 on file for this type
▸Inspections & Test Reports5
▸DOB NOWSOIL REPORT2
08/13/2026B00578168-S6Open ↗
Showing 1 of 2 on file for this type
▸BISTECHNICAL REPORT: RESPONSIBILITY1
09/16/2021340821837Open ↗
▸DOB NOWTR4 Test Report and Plot Diagram1
On file, but not among the 200 most recently loaded documents for this source.
Showing 0 of 1 on file for this type
▸DOB NOWTR4 Plot Diagram1
On file, but not among the 200 most recently loaded documents for this source.
Showing 0 of 1 on file for this type
▸Approvals, Objections & Sign-offs5
▸BISLETTERS - SUPPORTING DOCUMENTATION2
08/12/2024322117623Open ↗
08/12/2024322117623Open ↗
▸BISADMINISTRATIVE OBJECTIONS2
07/08/2014320941834Open ↗
07/08/2014320941825Open ↗
▸BISSCHEDULE A - OCCUPANCY / USE1
11/20/2017321686118Open ↗
▸Cost, Insurance & Ownership2
▸BISCOST AFFIDAVIT2
07/08/2014320941834Open ↗
07/08/2014320941825Open ↗
▸Filing & Intake Forms13
▸BISEFILING COVER SHEET10
07/31/2024322117623Open ↗
01/04/2018321705776Open ↗
01/04/2018321705767Open ↗
Showing 3 of 10 on file for this type
▸BISADDITIONAL INFORMATION2
06/04/2025340821837Open ↗
03/06/2025340821837Open ↗
▸BISEFILING JOB APPLICATION COVER SHEET1
09/16/2021340821837Open ↗
▸Other Documents29
▸DOB NOWSite Survey: Initial6
08/15/2026B00578168-I1Open ↗
08/13/2026B00578168-P9Open ↗
08/13/2026B00578168-A5Open ↗
Showing 3 of 6 on file for this type
▸DOB NOWLocal Law 92/94 of 2019 Sustainable Roof Zone6
08/15/2026B00578168-I1Open ↗
Showing 1 of 6 on file for this type
▸DOB NOWProperty Ownership Certification6
08/25/2026B00578168-P9Open ↗
08/25/2026B00578168-P2Open ↗
08/25/2026B00578168-P1Open ↗
Showing 3 of 6 on file for this type
▸BISPLOT DIAGRAM2
08/12/2024322117623Open ↗
11/20/2017321686118Open ↗
▸BISBPP - SUPPORTING DOCUMENTATION1
01/25/2024340821837Open ↗
▸BISVERIFY DOB PLAN NAMING STANDARD IS MET1
08/12/2024322117623Open ↗
▸BISBPP: TOPOGRAPHIC SURVEY1
01/25/2024340821837Open ↗
▸BISRECORDS MGMT FEE PAYMENT RECEIPT1
08/12/2024322117623Open ↗
▸DOB NOWManufacturer's Specifications1
On file, but not among the 200 most recently loaded documents for this source.
Showing 0 of 1 on file for this type
▸DOB NOWCalculations1
08/13/2026B00963712-I1Open ↗
▸DOB NOWFinal Survey1
On file, but not among the 200 most recently loaded documents for this source.
Showing 0 of 1 on file for this type
▸DOB NOWAdjoining Owners Notification1
08/13/2026B00578168-S2Open ↗
▸DOB NOWProject Specific General Liability (PGL1)1
08/13/2026B00578168-I1Open ↗