← Back
Two family brick
654 UNION STREET
BROOKLYN · BIN 3020053
💬 Discuss this project
1901Year Built
2Stories
B1Building Class
R6AZoning
1,980 sfGross Floor Area
2Units
Two family brick · 1,520 sf lot · 1.3 FAR built · Flood zone X
Locations of Work
ArchitecturePlumbing
Permit Issued — active, not yet Signed-off
Floor 2Under Construction5p · 1 filing · 17 docs
Floor 1Under Construction5p · 1 filing · 17 docs
CellarUnder Construction5p · 1 filing · 17 docs
Sub-BasementUnder Construction5p · 1 filing · 17 docs
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
BRIAN ILL DEVELOPMENT LLC204/26/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
KALE CONSTRUCTION INCGeneral Contractor107/08/2026
WATSON'S PLBG, HTG, & BDGPlumbing107/08/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
BRIAN ILL DEVELOPMENT LLC1402204/26/2026
Building Lifecycle
All (23)Filed (2)Permit Issued (2)Inspection (3)Special Inspection (16)
07/26/2026
Inspection — Certified Remove/Cap - work done in accordance with code
Certified
View inspection ↗
07/06/2026
Inspection — Pass-Final PL - Up to 3 Requested Floors
Pass
View inspection ↗
06/26/2026
Inspection — Certified Remove/Cap - work done in accordance with code
Certified
View inspection ↗
04/29/2026
Permit issued — Plumbing
B01392987-S1-PL
04/28/2026
Permit issued — General Construction
B01392987-I1-GC-CX
04/26/2026
Filed — Alteration
FILE PL WORKTYPE IN CONJUNCTION WITH JOB#B01392987
B01392987-S1
04/26/2026
Filed — Alteration
FILE PL WORKTYPE IN CONJUNCTION WITH JOB#B01392987
B01392987-I1
04/26/2026
Special inspection requirement — Fire-Resistant Penetrations and Joints
BRIAN ILL
04/26/2026
Special inspection requirement — Energy Code Compliance Inspections
BRIAN ILL
04/26/2026
Special inspection requirement — HVAC-R and service water piping design and insulation
BRIAN ILL
04/26/2026
Special inspection requirement — HVAC-R and service water heating equipment
BRIAN ILL
04/26/2026
Special inspection requirement — Maintenance information
BRIAN ILL
04/26/2026
Special inspection requirement — HVAC-R and service water heating system controls
BRIAN ILL
04/26/2026
Special inspection requirement — Mechanical Systems
BRIAN ILL
04/26/2026
Special inspection requirement — Fire-Resistant Penetrations and Joints
BRIAN ILL
04/26/2026
Special inspection requirement — Heating Systems
BRIAN ILL
04/26/2026
Special inspection requirement — Final
BRIAN ILL
04/26/2026
Special inspection requirement — Energy Code Compliance Inspections
BRIAN ILL
04/26/2026
Special inspection requirement — Fire-Resistance Rated Construction
BRIAN ILL
04/26/2026
Special inspection requirement — Maintenance information
BRIAN ILL
04/26/2026
Special inspection requirement — HVAC-R and service water heating equipment
BRIAN ILL
04/26/2026
Special inspection requirement — HVAC-R and service water piping design and insulation
BRIAN ILL
04/26/2026
Special inspection requirement — HVAC-R and service water heating system controls
BRIAN ILL
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWPlumbingPermit IssuedWATSON'S PLBG, HTG, & BDG04/29/2026
DOB NOWGeneral ConstructionPermit IssuedKALE CONSTRUCTION INC04/28/2026
1 project · most recent 04/26/2026
Heating Systems
FiledStatusContractorScopeMake / Model / Capacity
04/26/2026Permit IssuedKALE CONSTRUCTION INCHeating Systems
Heating
A.O. Smith XCG-50-400 48,000 BTU · Water Heater ×2
1 project · most recent 04/26/2026
Gas Water/Sanitary
FiledStatusContractorScope
04/26/2026Permit IssuedWATSON'S PLBG, HTG, & BDGGas, Water/Sanitary
▾Field Inspections (DOB CAP) — 3
DateTypeResultReport
07/26/2026Certified Remove/Cap - work done in accordance with codeCertifiedView ↗
07/06/2026Pass-Final PL - Up to 3 Requested FloorsPassView ↗
06/26/2026Certified Remove/Cap - work done in accordance with codeCertifiedView ↗
▾Special Inspection Requirements (DOB NOW) — 16
DateRequirementInspectorRole
04/26/2026Fire-Resistant Penetrations and JointsBRIAN ILLspecial
04/26/2026Energy Code Compliance InspectionsBRIAN ILLprogress
04/26/2026HVAC-R and service water piping design and insulationBRIAN ILLenergy_progress
04/26/2026HVAC-R and service water heating equipmentBRIAN ILLenergy_progress
04/26/2026Maintenance informationBRIAN ILLenergy_progress
04/26/2026HVAC-R and service water heating system controlsBRIAN ILLenergy_progress
04/26/2026Mechanical SystemsBRIAN ILLspecial
04/26/2026Fire-Resistant Penetrations and JointsBRIAN ILLspecial
04/26/2026Heating SystemsBRIAN ILLspecial
04/26/2026FinalBRIAN ILLprogress
04/26/2026Energy Code Compliance InspectionsBRIAN ILLprogress
04/26/2026Fire-Resistance Rated ConstructionBRIAN ILLprogress
04/26/2026Maintenance informationBRIAN ILLenergy_progress
04/26/2026HVAC-R and service water heating equipmentBRIAN ILLenergy_progress
04/26/2026HVAC-R and service water piping design and insulationBRIAN ILLenergy_progress
04/26/2026HVAC-R and service water heating system controlsBRIAN ILLenergy_progress
▾Documents — 17 on file (BIS + DOB NOW)
▸Plans & Drawings2
▸DOB NOWPlans/Sketch2
08/17/2026B01392987-I1Request digital key ↗
08/17/2026B01392987-S1Request digital key ↗
▸Seals & Professional Certifications14
▸DOB NOWProgress Inspector Seal & Signature10
08/30/2026B01392987-I1Open ↗
08/30/2026B01392987-I1Open ↗
08/30/2026B01392987-I1Open ↗
Showing 3 of 10 on file for this type
▸DOB NOWDPL-1: Design Professional Seal & Signature2
08/17/2026B01392987-S1Open ↗
08/17/2026B01392987-I1Open ↗
▸DOB NOWSpecial Inspector Seal & Signature2
08/30/2026B01392987-I1Open ↗
08/23/2026B01392987-S1Open ↗
▸Environmental & Asbestos1
▸DOB NOWDEP ACP-5: Asbestos Assessment Report1
08/17/2026B01392987-I1Open ↗