← Back
Elevator cooperative
66-15 WETHEROLE STREET
QUEENS · Forest Hills · BIN 4074677
💬 Discuss this project
1950Year Built
6Stories
D4Building Class
R7-1Zoning
90,300 sfGross Floor Area
113Units
LL97 CoveredRent Stabilized68 Open Violations ▸FISP: SWARMP
Elevator cooperative · 26,000 sf lot · 3.47 FAR built · Flood zone X
Locations of Work
Mechanical
Permit Issued — active, not yet Signed-off
CellarUnder Construction1p · 1 filing · 6 docs
Site & exteriorUnder Construction1 filing · 6 docs
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
METRO MANAGEMENT DEVEL303/21/2026
METRO MANAGEMENT DEVELOPMENT INC.203/21/2026
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
NEW AGE ENGINEERING PLLC106/09/2025
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
NEW AGE ENGINEERING PLLC7746106/09/2025
Building Lifecycle
All (79)Filed (1)Permit Issued (2)Facade (FISP) (12)Violation (60)Inspection (1)Special Inspection (3)
07/22/2026
Inspection — No Access-Final Boiler Equipment Inspection
No Access
View inspection ↗
07/13/2026
Violation issued (HPD, open)
C
07/13/2026
Violation issued (HPD, open)
C
07/13/2026
Violation issued (HPD, open)
B
07/13/2026
Violation issued (HPD, open)
B
07/13/2026
Violation issued (HPD, open)
B
07/13/2026
Violation issued (HPD, open)
B
07/13/2026
Violation issued (HPD, open)
B
07/06/2026
Permit issued — Boiler Equipment
Q01230325-I1-BE
02/14/2026
Violation issued (HPD, closed)
C
11/11/2025
Violation issued (HPD, open)
B
11/11/2025
Violation issued (HPD, open)
C
06/12/2025
Permit issued — Boiler Equipment
Q01230325-I1-BE
06/09/2025
Filed — Alteration
REPLACE EXISTING 5,000 GALLON OIL TANK WITH REPLACEMENT 3,000 GALLON OIL TANK AND CONVERT #4 OIL TO #2 OIL AS PER PLANS. NO CHANGE IN USE, OCCUPANCY, OR EGRESS.
Q01230325-I1
06/09/2025
Special inspection requirement — Fire-Resistant Penetrations and Joints
Stephen Shishko
05/22/2025
Special inspection requirement — Tenant Protection Plan Compliance
Stephen Shishko
05/22/2025
Special inspection requirement — Fuel-Oil Storage and Fuel-Oil Piping Systems
Stephen Shishko
08/29/2024
Violation issued (HPD, closed)
B
08/29/2024
Violation issued (HPD, open)
C
08/29/2024
Violation issued (HPD, closed)
A
08/29/2024
Violation issued (HPD, open)
C
11/24/2023
Violation issued (HPD, closed)
I
11/13/2023
Violation issued (HPD, open)
C
11/13/2023
Violation issued (HPD, open)
B
11/13/2023
Violation issued (HPD, closed)
C
11/13/2023
Violation issued (HPD, open)
C
11/13/2023
Violation issued (HPD, open)
B
11/13/2023
Violation issued (HPD, open)
B
06/14/2023
Violation issued (HPD, closed)
C
06/14/2023
Violation issued (HPD, closed)
C
06/14/2023
Violation issued (HPD, closed)
C
06/14/2023
Violation issued (HPD, closed)
C
06/14/2023
Violation issued (HPD, closed)
C
06/14/2023
Violation issued (HPD, closed)
C
06/14/2023
Violation issued (HPD, closed)
C
06/14/2023
Violation issued (HPD, closed)
C
06/14/2023
Violation issued (HPD, closed)
C
06/14/2023
Violation issued (HPD, closed)
C
02/16/2023
Cycle 9 facade report submitted
02/16/2023
Cycle 9 facade report signed — SWARMP
02/10/2023
Cycle 9 facade inspection completed
11/15/2022
Violation issued (HPD, closed)
I
06/05/2022
Violation issued (HPD, closed)
C
06/05/2022
Violation issued (HPD, closed)
B
06/05/2022
Violation issued (HPD, closed)
B
06/05/2022
Violation issued (HPD, closed)
B
06/05/2022
Violation issued (HPD, closed)
B
06/05/2022
Violation issued (HPD, closed)
B
06/05/2022
Violation issued (HPD, closed)
B
06/05/2022
Violation issued (HPD, closed)
B
12/23/2021
Violation issued (HPD, open)
B
12/17/2021
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
12/17/2021
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
09/03/2020
Violation issued (HPD, open)
B
09/03/2020
Violation issued (HPD, open)
B
09/03/2020
Violation issued (HPD, open)
C
09/03/2020
Violation issued (HPD, open)
B
08/15/2020
Violation issued (HPD, open)
C
08/15/2020
Violation issued (HPD, open)
B
08/15/2020
Violation issued (HPD, open)
A
Latest 60 of 79 events.
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWBoiler EquipmentPermit IssuedNEW YORK HEATING CORP07/06/2026
DOB NOWBoiler EquipmentPermit IssuedNEW YORK HEATING CORP06/12/2025
BISEQISSUEDXINOS CONSTRUCTION CORP03/11/2011
BISOTISSUEDXINOS CONSTRUCTION CORP03/11/2011
BISOTISSUEDNATIONAL MICROWAVE CONTRACTORS I09/29/1998
2 projects · most recent 08/18/2026
FiledStatusContractorScope
08/18/2026CompleteR & T ELECTRICAL CORP—
11/10/2021CompleteYORK ELEC'L CONTR'S INC.—
▾Field Inspections (DOB CAP) — 1
DateTypeResultReport
07/22/2026No Access-Final Boiler Equipment InspectionNo AccessView ↗
▾Special Inspection Requirements (DOB NOW) — 3
DateRequirementInspectorRole
06/09/2025Fire-Resistant Penetrations and JointsStephen Shishkospecial
05/22/2025Tenant Protection Plan ComplianceStephen Shishkospecial
05/22/2025Fuel-Oil Storage and Fuel-Oil Piping SystemsStephen Shishkospecial
▾Documents — 38 on file (BIS + DOB NOW)
▸Plans & Drawings1
▸DOB NOWPlans/Sketch1
08/20/2026Q01230325-I1Request digital key ↗
▸Applications & Permits5
▸BISPLAN / WORK APPROVAL APPLICATION3
10/17/2016421342577Open ↗
03/11/2011420331206Open ↗
02/02/2011420313672Open ↗
▸BISWORK PERMIT APPLICATION2
06/14/2011420331206Open ↗
03/11/2011420313672Open ↗
▸Seals & Professional Certifications11
▸BISTECHNICAL REPORT: RESPONSIBILITY/CERTIFICATION5
12/13/2017420331206Open ↗
09/19/2016421342577Open ↗
12/21/2011420313672Open ↗
Showing 3 of 5 on file for this type
▸DOB NOWSpecial Inspector Seal & Signature3
08/26/2026Q01230325-I1Open ↗
08/26/2026Q01230325-I1Open ↗
08/26/2026Q01230325-I1Open ↗
▸BISPROFESSIONAL CERTIFIED CHECKLIST1
03/11/2011420331206Open ↗
▸BISPROFESSIONAL CERTIFICATION STATEMENT FORM1
03/11/2011420331206Open ↗
▸DOB NOWDPL-1: Design Professional Seal & Signature1
08/13/2026Q01230325-I1Open ↗
▸Safety & Tenant Protection2
▸BISTenant Protection Plan and Notes1
09/19/2016421342577Open ↗
▸BISDEMOLITION SUBMITTAL CERTIFICATION FORM1
10/27/2016421342577Open ↗
▸Environmental & Asbestos4
▸BISASBESTOS: CERTIFICATION (DEP ACP5)1
09/19/2016421342577Open ↗
▸BISTHIS IS 'NOT AN ASBESTOS PROJECT'1
02/02/2011420313672Open ↗
▸BISASBESTOS EXEMPTION CERTIFICATION LETTER1
03/11/2011420331206Open ↗
▸DOB NOWDEP ACP-5: Asbestos Assessment Report1
08/13/2026Q01230325-I1Open ↗
▸Energy Compliance2
▸BISTECHNICAL REPORT: ENERGY CODE PROGRESS INSPS2
10/06/2016421342577Open ↗
09/19/2016421342577Open ↗
▸Approvals, Objections & Sign-offs5
▸BISCERTIFICATE OF OCCUPANCY/LOC: REQUEST2
12/13/2017420331206Open ↗
12/21/2011420313672Open ↗
▸BISADMINISTRATIVE OBJECTIONS2
03/11/2011420331206Open ↗
02/02/2011420313672Open ↗
▸BISLETTERS - SUPPORTING DOCUMENTATION1
12/21/2011420313672Open ↗
▸Cost, Insurance & Ownership4
▸BISCOST AFFIDAVIT4
10/18/2016421342577Open ↗
09/19/2016421342577Open ↗
12/21/2011420313672Open ↗
Showing 3 of 4 on file for this type
▸Filing & Intake Forms4
▸BISEFILING COVER SHEET3
09/19/2016421342577Open ↗
03/11/2011420331206Open ↗
02/02/2011420313672Open ↗
▸BISBOROUGH INTAKE FORM1
12/13/2017420331206Open ↗