| Date | Price | Unit | Seller → Buyer | $/sf |
|---|---|---|---|---|
| 03/01/2024 | $988K | — | MZO REALTY LLC → 6616 251ST LLC | $814/sf building |
| Firm | Filings | Most Recent |
|---|---|---|
| FANG ARCHITECT | 4 | 06/20/2025 |
| ALPHA HOME DESIGN LLC | 2 | 12/06/2024 |
| Representative | Filings | Most Recent |
|---|---|---|
| INDESIGN STUDIO | 10 | 03/21/2026 |
| Firm | Trade | Roles | Most Recent |
|---|---|---|---|
| JRY CONSTRUCTION INC | General Contractor | 13 | 04/08/2026 |
| WASOFF PLBG & UTILITY CO | Plumbing | 1 | 07/08/2026 |
| Agency | License # | Filings | Most Recent |
|---|---|---|---|
| FANG ARCHITECT | 5513 | 2 | 06/20/2025 |
| YAN GAO | 6619 | 2 | 12/06/2024 |
| Source | Work Type | Status | Applicant | Issued |
|---|---|---|---|---|
| DOB NOW | Curb Cut | Signed-off | JRY CONSTRUCTION INC | 08/26/2025 |
| DOB NOW | Structural | Permit Issued | JRY CONSTRUCTION INC | 12/13/2024 |
| DOB NOW | Construction Fence | Signed-off | JRY CONSTRUCTION INC | 12/05/2024 |
| DOB NOW | Structural | Permit Issued | JRY CONSTRUCTION INC | 07/15/2024 |
| DOB NOW | Plumbing | Signed-off | WASOFF PLBG & UTILITY CO | 07/12/2024 |
| DOB NOW | Construction Fence | Signed-off | JRY CONSTRUCTION INC | 06/10/2024 |
| Filed | Status | Contractor | Scope | Make / Model / Capacity |
|---|---|---|---|---|
| 06/20/2025 | Signed-off | JRY CONSTRUCTION INC | Heating and Air Conditioning Systems | Heat / Cool Midea DLCURAH60ABK 55,000 BTU · Heat Pump Outdoor ×2 |
| Filed | Status | Contractor | Scope |
|---|---|---|---|
| 06/20/2025 | Signed-off | WASOFF PLBG & UTILITY CO | Storm, Water/Sanitary |
| Filed | Status | Contractor | Scope |
|---|---|---|---|
| 08/12/2024 | Complete | KJK ELECTRIC INC | General Wiring |
| Filed | Status | Contractor | Scope |
|---|---|---|---|
| 06/20/2025 | Signed-off | JRY CONSTRUCTION INC | Wood |
| Date | Type | Result | Report |
|---|---|---|---|
| 09/04/2025 | Pass-Final Curb Cut Non-Directive 14 | Pass | View ↗ |
| 08/25/2025 | Certified Water and Sanitary-WS-Fixtures-Finish | Certified | View ↗ |
| 08/25/2025 | Pass-Final CND-Occupancy Inspection | Pass | View ↗ |
| 08/15/2025 | Fail-Final CND-Occupancy Inspection | Fail | View ↗ |
| 05/13/2025 | Certified Remove/Cap - work done in accordance with code | Certified | View ↗ |
| 05/13/2025 | Certified Sprinkler-SP-Piping Dry/Wet-Hydrostatic Test | Certified | View ↗ |
| 05/13/2025 | Certified Sprinkler - SP - Roughing | Certified | View ↗ |
| 12/27/2024 | Certified Storm Drainage-ST-Piping-Underground | Certified | View ↗ |
| 12/27/2024 | Certified Water and Sanitary-WS-Sanitary Piping-Roughing | Certified | View ↗ |
| 12/27/2024 | Certified Water and Sanitary-WS-Sanitary Piping-Underground | Certified | View ↗ |
| 12/20/2024 | Certified Remove/Cap - work done in accordance with code | Certified | View ↗ |
| Date | Requirement | Inspector | Role |
|---|---|---|---|
| 07/28/2025 | Fire-Resistant Penetrations and Joints | DEZHANG FANG | special |
| 07/28/2025 | Concrete - Cast-In-Place | DEZHANG FANG | special |
| 07/28/2025 | Masonry | DEZHANG FANG | special |
| 07/28/2025 | Mechanical Systems | DEZHANG FANG | special |
| 07/28/2025 | Subgrade Inspections | DEZHANG FANG | special |
| 07/28/2025 | Structural Stability – Alterations of existing buildings | DEZHANG FANG | special |
| 07/28/2025 | Structural Wood Frame | DEZHANG FANG | progress |
| 07/28/2025 | Energy Code Compliance Inspections | DEZHANG FANG | progress |
| 07/28/2025 | Final | DEZHANG FANG | progress |
| 07/28/2025 | Duct leakage testing, insulation and design | DEZHANG FANG | energy_progress |
| 07/28/2025 | HVAC-R and service water heating equipment | DEZHANG FANG | energy_progress |
| 07/28/2025 | HVAC-R and service water heating system controls | DEZHANG FANG | energy_progress |
| 07/28/2025 | Ventilation and air distribution system | DEZHANG FANG | energy_progress |
| 07/28/2025 | Interior lighting power | DEZHANG FANG | energy_progress |
| 07/28/2025 | Protection of exposed foundation insulation | DEZHANG FANG | energy_progress |
| 07/28/2025 | Fenestration areas | DEZHANG FANG | energy_progress |
| 07/28/2025 | Air barrier — testing | DEZHANG FANG | energy_progress |
| 07/28/2025 | Footing and Foundation | DEZHANG FANG | progress |
| 07/28/2025 | Fire-Resistance Rated Construction | DEZHANG FANG | progress |
| 07/28/2025 | Maintenance information | DEZHANG FANG | energy_progress |
| 07/28/2025 | Permanent certificate | DEZHANG FANG | energy_progress |
| 07/28/2025 | Metering | DEZHANG FANG | energy_progress |
| 07/28/2025 | Insulation placement and R values | DEZHANG FANG | energy_progress |
| 07/28/2025 | Air barrier - visual inspection | DEZHANG FANG | energy_progress |
| 07/28/2025 | Electric vehicle service equipment requirements | DEZHANG FANG | energy_progress |