← Back
Three families
661 JEFFERSON AVENUE
BROOKLYN · BIN 3045519
💬 Discuss this project
1899Year Built
3Stories
C0Building Class
R6BZoning
3,536 sfGross Floor Area
3Units
0 Open ViolationsFDNY Report ↗
Three families · 2,000 sf lot · 1.77 FAR built · Flood zone X
Locations of Work
No floor-level scope or drawing coverage on file for this building.
▾Sales History (ACRIS)
DatePriceUnitSeller → Buyer$/sf
10/30/2018$1.6M—Private party → Private party$452/sf building
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
MICHAEL SCADUTO ARCHITECT212/21/2021
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
LOPOPOLO IRON WORKS INCGeneral Contractor107/08/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
MICHAEL SCADUTO ARCHITECT4833212/21/2021
Building Lifecycle
All (20)Filed (2)Permit Issued (1)Signed Off (1)Violation (2)Inspection (2)Objection (6)Special Inspection (6)
01/04/2022
Signed off — Alteration
NEW REAR YARD DECK AT 1ST FLOOR
B00523106-I1
12/30/2021
Inspection — Pass-Final General Construction Non-Directive 14
Pass
View inspection ↗
12/27/2021
Objection raised — Cost
12/27/2021
Objection resolved — Addressed
12/27/2021
Objection raised — Zoning
12/27/2021
Objection resolved — Addressed
12/27/2021
Objection raised — Structural
12/27/2021
Objection resolved — Addressed
12/21/2021
Filed — Alteration
NEW REAR YARD DECK AT 1ST FLOOR
B00523106-P1
12/07/2021
Special inspection requirement — Concrete - Cast-In-Place
Michael Scaduto
12/07/2021
Special inspection requirement — Post-installed Anchors
Michael Scaduto
12/07/2021
Special inspection requirement — Energy Code Compliance Inspections
Michael Scaduto
12/07/2021
Special inspection requirement — Air barrier - visual inspection
Michael Scaduto
12/07/2021
Special inspection requirement — Fenestration air leakage
Michael Scaduto
12/07/2021
Special inspection requirement — Fenestration and door U-factor and product ratings
Michael Scaduto
10/14/2021
Inspection — Fail-Final General Construction Non-Directive 14
Fail
View inspection ↗
07/28/2021
Permit issued — General Construction
B00523106-I1-GC
05/17/2021
Filed — Alteration
NEW REAR YARD DECK AT 1ST FLOOR
B00523106-I1
09/21/2016
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
06/22/2016
Violation issued (ECB, closed)
Construction
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWGeneral ConstructionSigned-offLOPOPOLO IRON WORKS INC07/28/2021
2 projects · most recent 09/11/2019
General Wiring
FiledStatusContractorScope
09/11/2019Permit IssuedAMRA ELECTRICAL CORPGeneral Wiring
03/03/2019Permit IssuedGEORGE HOLNESSGeneral Wiring
▾Field Inspections (DOB CAP) — 2
DateTypeResultReport
12/30/2021Pass-Final General Construction Non-Directive 14PassView ↗
10/14/2021Fail-Final General Construction Non-Directive 14FailView ↗
▾Special Inspection Requirements (DOB NOW) — 6
DateRequirementInspectorRole
12/07/2021Concrete - Cast-In-PlaceMichael Scadutospecial
12/07/2021Post-installed AnchorsMichael Scadutospecial
12/07/2021Energy Code Compliance InspectionsMichael Scadutoprogress
12/07/2021Air barrier - visual inspectionMichael Scadutoenergy_progress
12/07/2021Fenestration air leakageMichael Scadutoenergy_progress
12/07/2021Fenestration and door U-factor and product ratingsMichael Scadutoenergy_progress
▾Documents — 7 on file (BIS + DOB NOW)
▸Plans & Drawings2
▸DOB NOWPlans/Sketch2
09/01/2026B00523106-I1Request digital key ↗
08/14/2026B00523106-P1Request digital key ↗
▸Seals & Professional Certifications4
▸DOB NOWDPL-1: Design Professional Seal & Signature2
08/13/2026B00523106-I1Open ↗
08/13/2026B00523106-P1Open ↗
▸DOB NOWProgress Inspector Seal & Signature2
08/26/2026B00523106-P1Open ↗
08/26/2026B00523106-P1Open ↗
▸Energy Compliance1
▸DOB NOWEN2: As Built Energy Analysis.1
08/13/2026B00523106-I1Open ↗