← Back
Two stories - detached, small or mid-size
661 WOODROW ROAD
STATEN ISLAND · Arden Heights-Rossville · BIN 5077644
💬 Discuss this project
1935Year Built
2.5Stories
A1Building Class
R3XZoning
—Gross Floor Area
1Units
0 Open ViolationsFDNY Report ↗
Two stories - detached, small or mid-size · 0.31 FAR built · Flood zone X
Locations of Work
ArchitectureElectrical
Roof1p · 1 filing · 6 docs
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
GREEN RIVER ENVIRONMENTAL ENGINEERI108/06/2024
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
NY State Solar LLC203/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
NYSS LLCGeneral Contractor303/21/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
GREEN RIVER ENVIRONMENTAL7841108/06/2024
Building Lifecycle
All (8)Filed (1)Permit Issued (1)Violation (1)Special Inspection (5)
08/12/2024
Permit issued — Solar
S01092318-I1-SL
08/06/2024
Filed — Alteration
INSTALLATION OF PHOTOVOLTAIC SOLAR ARRAY ON EXISTING ROOF SYSTEM AS PER PLANS
S01092318-I1
08/06/2024
Special inspection requirement — Fire-Resistant Penetrations and Joints
ROBERT MASONE
08/06/2024
Special inspection requirement — Structural Stability – Alterations of existing buildings
ROBERT MASONE
08/06/2024
Special inspection requirement — Energy Code Compliance Inspections
ROBERT MASONE
08/06/2024
Special inspection requirement — Final
ROBERT MASONE
08/06/2024
Special inspection requirement — Air barrier - visual inspection
ROBERT MASONE
06/18/2004
Violation issued (ECB, closed)
Construction
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWSolarPermit IssuedNYSS LLC08/12/2024
BIS—ISSUEDOWNER03/11/2004
BISOTISSUEDN/A04/16/1997
1 project · most recent 07/29/2024
FiledStatusContractorScope
07/29/2024Permit IssuedNY SOLAR ELECTRICAL LLC—
1 project · most recent 08/06/2024
FiledStatusContractorScope
08/06/2024Permit IssuedNYSS LLC15 panels, 6.15 kw, 1,569 roof_area_sqft
▾Special Inspection Requirements (DOB NOW) — 5
DateRequirementInspectorRole
08/06/2024Fire-Resistant Penetrations and JointsROBERT MASONEspecial
08/06/2024Structural Stability – Alterations of existing buildingsROBERT MASONEspecial
08/06/2024Energy Code Compliance InspectionsROBERT MASONEprogress
08/06/2024FinalROBERT MASONEprogress
08/06/2024Air barrier - visual inspectionROBERT MASONEenergy_progress
▾Documents — 6 on file (BIS + DOB NOW)
▸Plans & Drawings1
▸DOB NOWPlans/Sketch1
08/21/2026S01092318-I1Request digital key ↗
▸Seals & Professional Certifications4
▸DOB NOWProgress Inspector Seal & Signature2
10/03/2026S01092318-I1Open ↗
10/03/2026S01092318-I1Open ↗
▸DOB NOWDPL-1: Design Professional Seal & Signature1
08/13/2026S01092318-I1Open ↗
▸DOB NOWSpecial Inspector Seal & Signature1
10/03/2026S01092318-I1Open ↗
▸Environmental & Asbestos1
▸DOB NOWDEP ACP-5: Asbestos Assessment Report1
08/13/2026S01092318-I1Open ↗