← Back
Miscellaneous two family
662 49 STREET
BROOKLYN · BIN 3013041
💬 Discuss this project
1930Year Built
2Stories
B9Building Class
R6BZoning
2,280 sfGross Floor Area
2Units
Miscellaneous two family · 2,003 sf lot · 1.14 FAR built · Flood zone X
Locations of Work
ArchitecturePlumbingGeneral
Floor 22p · 2 filings · 12 docs
Floor 13p · 2 filings · 12 docs
Cellar3p · 2 filings · 12 docs
▾Sales History (ACRIS)
DatePriceUnitSeller → Buyer$/sf
04/26/2023$1.5M—— → —$662/sf building
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
BASSIRI409/29/2023
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
ECDESIGN STUDIO803/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
KLE CONSTRUCTION INCGeneral Contractor107/08/2026
CATMAN PLUMBING INCPlumbing107/08/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
BASSIRI8394209/29/2023
Building Lifecycle
All (18)Filed (4)Permit Issued (2)Signed Off (2)Inspection (4)Special Inspection (6)
10/26/2023
Signed off — Alteration
RENOVATION OF EXISTING CELLAR, FIRST AND SECOND FLOOR WITH PLUMBING WORK:RELOCATE KITCHEN AND BATHROOM FIXTURES; NEW BOILERS AND HOT WATER HEATERS ON CELLAR; NO CHANGE IN USE, EGRESS OR OCCUPANCY UNDER THIS APPLICATION.
B00873130-I1
10/26/2023
Signed off — Alteration
RENOVATION OF EXISTING CELLAR, FIRST AND SECOND FLOOR WITH GENERAL CONSTRUCTION: NEW PARTITIONS, DOORS, FLOORING AND COSMETIC WORK; NO CHANGE IN USE, EGRESS OR OCCUPANCY UNDER THIS APPLICATION.
B00873125-I1
10/25/2023
Inspection — Pass-Final General Construction Non-Directive 14
Pass
View inspection ↗
10/17/2023
Inspection — Fail-Final General Construction Non-Directive 14
Fail
View inspection ↗
09/29/2023
Filed — Alteration
RENOVATION OF EXISTING CELLAR, FIRST AND SECOND FLOOR WITH GENERAL CONSTRUCTION: NEW PARTITIONS, DOORS, FLOORING AND COSMETIC WORK; NO CHANGE IN USE, EGRESS OR OCCUPANCY UNDER THIS APPLICATION.
B00873125-P1
09/29/2023
Filed — Alteration
RENOVATION OF EXISTING CELLAR, FIRST AND SECOND FLOOR WITH PLUMBING WORK:RELOCATE KITCHEN AND BATHROOM FIXTURES; NEW BOILERS AND HOT WATER HEATERS ON CELLAR; NO CHANGE IN USE, EGRESS OR OCCUPANCY UNDER THIS APPLICATION.
B00873130-P1
09/29/2023
Special inspection requirement — Fire-Resistant Penetrations and Joints
FARHAD BASSIRI-TEHRANI
09/29/2023
Special inspection requirement — Energy Code Compliance Inspections
FARHAD BASSIRI-TEHRANI
09/29/2023
Special inspection requirement — Fire-Resistance Rated Construction
FARHAD BASSIRI-TEHRANI
09/29/2023
Special inspection requirement — Fire-Resistant Penetrations and Joints
FARHAD BASSIRI-TEHRANI
09/29/2023
Special inspection requirement — Fire-Resistance Rated Construction
FARHAD BASSIRI-TEHRANI
09/29/2023
Special inspection requirement — Energy Code Compliance Inspections
FARHAD BASSIRI-TEHRANI
07/13/2023
Inspection — Certified Storm Drainage-ST-Piping-Underground
Certified
View inspection ↗
07/13/2023
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Roughing
Certified
View inspection ↗
06/21/2023
Permit issued — Plumbing
B00873130-I1-PL
05/26/2023
Permit issued — General Construction
B00873125-I1-GC
05/24/2023
Filed — Alteration
RENOVATION OF EXISTING CELLAR, FIRST AND SECOND FLOOR WITH PLUMBING WORK:RELOCATE KITCHEN AND BATHROOM FIXTURES; NEW BOILERS AND HOT WATER HEATERS ON CELLAR; NO CHANGE IN USE, EGRESS OR OCCUPANCY UNDER THIS APPLICATION.
B00873130-I1
05/24/2023
Filed — Alteration
RENOVATION OF EXISTING CELLAR, FIRST AND SECOND FLOOR WITH GENERAL CONSTRUCTION: NEW PARTITIONS, DOORS, FLOORING AND COSMETIC WORK; NO CHANGE IN USE, EGRESS OR OCCUPANCY UNDER THIS APPLICATION.
B00873125-I1
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWPlumbingSigned-offCATMAN PLUMBING INC06/21/2023
DOB NOWGeneral ConstructionSigned-offKLE CONSTRUCTION INC05/26/2023
Nothing on file for this building.
▾Field Inspections (DOB CAP) — 4
DateTypeResultReport
10/25/2023Pass-Final General Construction Non-Directive 14PassView ↗
10/17/2023Fail-Final General Construction Non-Directive 14FailView ↗
07/13/2023Certified Storm Drainage-ST-Piping-UndergroundCertifiedView ↗
07/13/2023Certified Water and Sanitary-WS-Sanitary Piping-RoughingCertifiedView ↗
▾Special Inspection Requirements (DOB NOW) — 6
DateRequirementInspectorRole
09/29/2023Fire-Resistant Penetrations and JointsFARHAD BASSIRI-TEHRANIspecial
09/29/2023Energy Code Compliance InspectionsFARHAD BASSIRI-TEHRANIprogress
09/29/2023Fire-Resistance Rated ConstructionFARHAD BASSIRI-TEHRANIprogress
09/29/2023Fire-Resistant Penetrations and JointsFARHAD BASSIRI-TEHRANIspecial
09/29/2023Fire-Resistance Rated ConstructionFARHAD BASSIRI-TEHRANIprogress
09/29/2023Energy Code Compliance InspectionsFARHAD BASSIRI-TEHRANIprogress
▾Documents — 12 on file (BIS + DOB NOW)
▸Plans & Drawings4
▸DOB NOWPlans/Sketch4
08/27/2026B00873130-P1Request digital key ↗
08/27/2026B00873130-I1Request digital key ↗
08/27/2026B00873125-I1Request digital key ↗
Showing 3 of 4 on file for this type
▸Seals & Professional Certifications8
▸DOB NOWDPL-1: Design Professional Seal & Signature4
08/27/2026B00873130-P1Open ↗
08/27/2026B00873130-I1Open ↗
08/27/2026B00873125-I1Open ↗
Showing 3 of 4 on file for this type
▸DOB NOWProgress Inspector Seal & Signature2
08/22/2026B00873125-I1Open ↗
08/22/2026B00873125-P1Open ↗
▸DOB NOWSpecial Inspector Seal & Signature2
08/22/2026B00873125-P1Open ↗
08/22/2026B00873125-I1Open ↗