← Back
Two family brick
6635 WALLASTON COURT
BROOKLYN · Bensonhurst · BIN 3134219
💬 Discuss this project
1935Year Built
2Stories
B1Building Class
R5Zoning
1,860 sfGross Floor Area
2Units
0 Open ViolationsFDNY Report ↗
Two family brick · 1,887 sf lot · 0.99 FAR built · Flood zone X
Locations of Work
ArchitecturePlumbing
Floor 210p · 2 filings · 12 docs
Floor 110p · 2 filings · 12 docs
Sub-Basement8p · 2 filings · 12 docs
Site & exterior3p · 1 filing · 8 docs
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
BASSIRI509/26/2024
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
ECDESIGN STUDIO1003/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
KLE CONSTRUCTION INCGeneral Contractor107/08/2026
AMC PLBG, HTG & CLNG, INCPlumbing107/08/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
BASSIRI8394309/26/2024
Building Lifecycle
All (13)Filed (5)Permit Issued (2)Signed Off (2)Violation (1)Inspection (3)
10/28/2024
Signed off — Alteration
RENOVATION OF EXISTING BASEMENT, FIRST AND SECOND FLOOR WITH GENERAL CONSTRUCTION: NEW PARTITIONS, DOORS, FLOORING AND COSMETIC WORK; NO CHANGE IN USE, EGRESS OR OCCUPANCY UNDER THIS APPLICATION.
B01093273-I1
10/25/2024
Inspection — Pass-Final General Construction Non-Directive 14
Pass
View inspection ↗
10/15/2024
Signed off — Alteration
RENOVATION OF EXISTING BASEMENT, FIRST AND SECOND FLOOR WITH PLUMBING WORK AS PER PLAN. NO CHANGE IN USE, EGRESS OR OCCUPANCY UNDER THIS APPLICATION
B01093280-I1
10/07/2024
Inspection — Fail-Final General Construction Non-Directive 14
Fail
View inspection ↗
09/30/2024
Inspection — Certified Water and Sanitary-WS-Fixtures-Finish
Certified
View inspection ↗
09/26/2024
Filed — Alteration
RENOVATION OF EXISTING BASEMENT, FIRST AND SECOND FLOOR WITH GENERAL CONSTRUCTION: NEW PARTITIONS, DOORS, FLOORING AND COSMETIC WORK; NO CHANGE IN USE, EGRESS OR OCCUPANCY UNDER THIS APPLICATION.
B01093273-P2
09/26/2024
Filed — Alteration
RENOVATION OF EXISTING BASEMENT, FIRST AND SECOND FLOOR WITH PLUMBING WORK AS PER PLAN. NO CHANGE IN USE, EGRESS OR OCCUPANCY UNDER THIS APPLICATION
B01093280-P1
09/05/2024
Filed — Alteration
RENOVATION OF EXISTING BASEMENT, FIRST AND SECOND FLOOR WITH GENERAL CONSTRUCTION: NEW PARTITIONS, DOORS, FLOORING AND COSMETIC WORK; NO CHANGE IN USE, EGRESS OR OCCUPANCY UNDER THIS APPLICATION.
B01093273-P1
08/20/2024
Permit issued — Plumbing
B01093280-I1-PL
08/19/2024
Permit issued — General Construction
B01093273-I1-GC
08/16/2024
Filed — Alteration
RENOVATION OF EXISTING BASEMENT, FIRST AND SECOND FLOOR WITH GENERAL CONSTRUCTION: NEW PARTITIONS, DOORS, FLOORING AND COSMETIC WORK; NO CHANGE IN USE, EGRESS OR OCCUPANCY UNDER THIS APPLICATION.
B01093273-I1
08/16/2024
Filed — Alteration
RENOVATION OF EXISTING BASEMENT, FIRST AND SECOND FLOOR WITH PLUMBING WORK AS PER PLAN. NO CHANGE IN USE, EGRESS OR OCCUPANCY UNDER THIS APPLICATION
B01093280-I1
07/13/2013
Violation issued (ECB, closed)
Unknown
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWPlumbingSigned-offAMC PLBG, HTG & CLNG, INC08/20/2024
DOB NOWGeneral ConstructionSigned-offKLE CONSTRUCTION INC08/19/2024
BISOTISSUEDKINGS STAR CONSTRUCTION C08/15/2013
Nothing on file for this building.
▾Field Inspections (DOB CAP) — 3
DateTypeResultReport
10/25/2024Pass-Final General Construction Non-Directive 14PassView ↗
10/07/2024Fail-Final General Construction Non-Directive 14FailView ↗
09/30/2024Certified Water and Sanitary-WS-Fixtures-FinishCertifiedView ↗
▾Special Inspection Requirements (DOB NOW) — 3
DateRequirementInspectorRole
09/05/2024Fire-Resistant Penetrations and JointsFARHAD BASSIRI-TEHRANIspecial
09/05/2024Energy Code Compliance InspectionsFARHAD BASSIRI-TEHRANIprogress
09/05/2024Fire-Resistance Rated ConstructionFARHAD BASSIRI-TEHRANIprogress
▾Documents — 26 on file (BIS + DOB NOW)
▸Plans & Drawings5
▸DOB NOWPlans/Sketch5
08/24/2026B01093280-P1Request digital key ↗
08/24/2026B01093280-I1Request digital key ↗
08/24/2026B01093273-P2Request digital key ↗
Showing 3 of 5 on file for this type
▸Applications & Permits3
▸BISWORK PERMIT APPLICATION2
08/23/2013320834790Open ↗
07/31/2013320834790Open ↗
▸BISPLAN / WORK APPROVAL APPLICATION1
07/31/2013320834790Open ↗
▸Seals & Professional Certifications10
▸DOB NOWDPL-1: Design Professional Seal & Signature5
08/24/2026B01093280-I1Open ↗
08/24/2026B01093280-P1Open ↗
08/24/2026B01093273-I1Open ↗
Showing 3 of 5 on file for this type
▸BISTECHNICAL REPORT: RESPONSIBILITY-CERTIFICATION1
07/31/2013320834790Open ↗
▸BISPROFESSIONAL CERTIFIED CHECKLIST1
07/31/2013320834790Open ↗
▸BISPROFESSIONAL CERTIFICATION STATEMENT FORM1
07/31/2013320834790Open ↗
▸DOB NOWProgress Inspector Seal & Signature1
08/25/2026B01093273-P1Open ↗
▸DOB NOWSpecial Inspector Seal & Signature1
08/25/2026B01093273-P1Open ↗
▸Energy Compliance2
▸BISTR8: Energy Code Progress Inspections1
07/31/2013320834790Open ↗
▸BISEN2 - As Built Energy Analysis1
10/16/2014320834790Open ↗
▸Approvals, Objections & Sign-offs2
▸BISCERTIFICATE OF OCCUPANCY/LOC: REQUEST1
10/16/2014320834790Open ↗
▸BISADMINISTRATIVE OBJECTIONS1
07/31/2013320834790Open ↗
▸Cost, Insurance & Ownership1
▸BISCOST AFFIDAVIT1
07/31/2013320834790Open ↗
▸Filing & Intake Forms2
▸BISADDITIONAL INFORMATION1
08/20/2014320834790Open ↗
▸BISEFILING COVER SHEET1
07/25/2013320834790Open ↗
▸Other Documents1
▸BISOP-4 - Special Report1
10/16/2014320834790Open ↗