ECB01/13/2023AT TIME OF INSPECTION ON A 2 STORY BUILDING I OBSERVED NO COMPLIANCE FROM RESPONDENT FOR PREVIOUSLY ISSUED VIOLATION 039508625K ISSUED ON 11/2/22 FOR INADEQUATE HOUSEKEEPING. RESPONDENT FAILED TO SUBMIT TO THE$6K due
DOB08/20/2022APPLICANT ON RECORD, ALBERTO ROMAN, PE#95364 SURRENDERED ALL .FILING PRIVILEGES, THEREFORE PURSUANT TO AC 28-105.10.2 BOROUGH .COMMISSIONER HAS ORDERED ALL WORK STOPPED UNDER JOB #B00630230-L1
DOB08/20/2022APPLICANT ON RECORD, ALBERTO ROMAN, PE#95364 SURRENDERED ALL .FILING PRIVILEGES, THEREFORE PURSUANT TO AC 28-105.10.2 BOROUGH .COMMISSIONER HAS ORDERED ALL WORK STOPPED UNDER JOB #B00630230-L1
DOB06/08/2022FAILURE TO COMPLY WITH COMMISSIONER'S ORDER #357105(081021FEU30102PN) DATED 8/10/2021 REQUESTING OWNER TO START PERMANENT REPAIRS OF THE BLDG DUE TO UNPERMITTED PARTIAL DEMOLITION AND EXCAVATION ALONT THE FRONT PORTTION OF THE BLDG AT EXP1 ALONG KENT AVE. REMEDY: IMMED COMPLY WITH COMMISSIONER'S ORDER #357105(081021FEU30102PN)
DOB11/10/2021FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION
DOB11/10/2021FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION
DOB11/10/2021FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION
DOB08/10/2021FTM BLDG SAFE CONDN:EXP1,1ST FL SLAB AREA APPROX 56'WX30'D EXCAV W/OUT PRMT&PROPER SUPRT OF EXCAV.FDN'S IMPRP EXP'D.1FL WD FRMG APRX 20'WX8'D INADQ SUPRT'D.EXP 1,2,3 INTER SIDES-WALLS PRTLY RMVD,CRCKD,+LOOSE.CEIL PRTLY RMVD+LOOSE.OWNR TO RETN NYSPE TO PREP+FILE REPR DRWGS.BLDG TO BE PERMNTLY REPRD UNDER PERMT STRT BY 9/14/21+CMPLTD/SIGNOFF BY 10/29/21
DOB08/10/2021STRUCTURE RENDERED NON COMPLIANT. AT TIME OF INSPECTION AT EXPOSURE 1, AT CELLAR LEVEL, AREA APPROXIMATELY 60' X 30' HAS BEEN EXCAVATED AND CONCRETE RUBBLE PILED, JOISTS NOT STABLE AND SECTIONS OF DROP CEILING HANGS LOOSE AND IS IN DANGER OF FALLING. VACATE CELLAR AREA FORTHWITH.
DOB08/10/2021EWO:EXP1 1FLR CONCR SLAB DEMO,W/OUT PRMT.EXP 1&2 FOUND EXP'D.EXP 1,2,3 WALLS @FRONT 30'-BLDG PARTLY REMVD MASN W/CRK'D/UNSUPRTD SECTNS.SECTNS 1FLR WD FRMG INADQ SUPRTD.CEIL ABVE FRONT SECTN PARTLY REMVD AND INADQ SUPRTD.OWNR RETN NYSPE&CONTR-IMMD SHOR INADQ SUPRTD 1FL FRMG.PLAC SOIL BERM @EXP'D FDN.BRCE+REMV LOOSE MASN WALLS&CEIL.PE SUPERV.FILE 2 DAYS
DOB08/09/2021DUE TO UNSAFE ELECTRICAL AND UNSAFE GAS LINES. ALSO OBSERVED UNPERMITE D EXCASVATION
ECB08/10/2021I OBSERVED ON TOP FLOOR OF SYNAGOGUE SEVERAL PAINTED SPRINKLER HEADS THROUGHOUT BUILDING WHICH IS PROHIBITED AND NOT CODE COMPLAINT SINCE IT WILL PREVENT PROPER FIRE PROTECTION OF THAT AREA OF BUILDING IN CASENothing owed — awaiting certificate of correction
ECB08/10/2021PROHIBITED MATERIAL; I OBSERVED ON TOP FLOOR OF SYNAGOGUE GAS PIPING HUNG SEVERAL TIMES WITH ELECTRIC WIRE WHICH IS NOT THE PROPER HANGERS AND IS PROHIBITED AND NOT CODE-COMPLAINT, REPAIR AND/REPLACENothing owed — awaiting certificate of correction
ECB08/10/2021I OBSERVED IN GAS METER AREA FOR SYNAGOGUE GAS PIPING REMOVED AND OPEN ENDED AT TIME OF INSPECTION NOT CAPPED AND OR PLUGGED FOR SAFETY WHICH IS PROHIBITED AND NOT CODE COMPLAINT AS PER FGC 404.13, I ALSO OBSERNothing owed — awaiting certificate of correction
ECB09/14/2009FAILURE TO COMPLY WITH AN ORDER OF THE COMMISSIONER TO OBTAIN A PERMITPER VIOLATIONS 334757160P BUILDING ILLEGALLY CONVERTED TO A COMMUNITY FACILITY/SYNAGOGUE UNDER DISAPPROVED APPLICATION #301896768. NO HAS BENothing owed — awaiting certificate of correction