1949Year Built
2Stories
C6Building Class
R3-2Zoning
554,300 sfGross Floor Area
467Units
LL97 CoveredRent Stabilized3 Open Violations 0 unresolved · 3 paperwork only ▸FDNY Report ↗
Walk-up cooperative · Owner of record: BELL PARK GARDENS · 902,780 sf lot · 0.61 FAR built · Flood zone X
Locations of Work
No floor-level scope or drawing coverage on file for this building.
1 job · most recent 12/15/2025
Water/Sanitary
FiledStatusContractorScope
12/15/2025Signed-offXH&RC PLBG AND HTG INCWater/Sanitary
1 job · most recent 12/24/2025
General Wiring
FiledStatusContractorScope
12/24/2025CompleteR & T ELECTRICAL CORPGeneral Wiring
1 job · most recent 12/15/2025
Tenant Protection Plan 72 Hour
FiledStatusContractorScope
12/15/2025Signed-offXH&RC PLBG AND HTG INCTenant Protection Plan 72 Hour
Building Lifecycle
All (13)Filed (2)Permit Issued (2)Signed Off (2)Inspection (2)Special Inspection (5)
05/01/2026
Signed off — Alteration
INTERIOR ALTERATION OF AN EXISTING SINGLE-FAMILY DUPLEX UNIT WITH PLUMBING WORK. NO CHANGE IN USE, OCCUPANCY OR EGRESS.
Q01333984-I1
05/01/2026
Signed off — Alteration
INTERIOR ALTERATION OF AN EXISTING SINGLE-FAMILY DUPLEX UNIT WITH PLUMBING WORK. NO CHANGE IN USE, OCCUPANCY OR EGRESS.
Q01333984-S1
03/23/2026
Inspection — Certified Water and Sanitary-WS-Fixtures-Finish
Certified
View inspection ↗
01/30/2026
Inspection — Pass-Final PL - Up to 3 Requested Floors
Pass
View inspection ↗
01/07/2026
Permit issued — Plumbing
Q01333984-S1-PL
12/23/2025
Permit issued — General Construction
Q01333984-I1-GC
12/15/2025
Filed — Alteration
INTERIOR ALTERATION OF AN EXISTING SINGLE-FAMILY DUPLEX UNIT WITH PLUMBING WORK. NO CHANGE IN USE, OCCUPANCY OR EGRESS.
Q01333984-I1
12/15/2025
Filed — Alteration
INTERIOR ALTERATION OF AN EXISTING SINGLE-FAMILY DUPLEX UNIT WITH PLUMBING WORK. NO CHANGE IN USE, OCCUPANCY OR EGRESS.
Q01333984-S1
12/15/2025
Special inspection requirement — Fire-Resistant Penetrations and Joints
XIAO ZHENG
12/15/2025
Special inspection requirement — Energy Code Compliance Inspections
XIAO ZHENG
12/15/2025
Special inspection requirement — Fire-Resistance Rated Construction
XIAO ZHENG
12/15/2025
Special inspection requirement — Final
XIAO ZHENG
12/15/2025
Special inspection requirement — Interior lighting power
XIAO ZHENG
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
ZHENG ENGINEERING PLLC212/15/2025
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
PRIMROSE SERVICE INCGeneral Contractor303/21/2026
XH&RC PLBG AND HTG INCPlumbing107/08/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
ZHENG ENGINEERING PLLC8512212/15/2025
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWPlumbingSigned-offXH&RC PLBG AND HTG INC01/07/2026
DOB NOWGeneral ConstructionSigned-offPRIMROSE SERVICE INC12/23/2025
▾Field Inspections (DOB CAP) — 2
DateTypeResultReport
03/23/2026Certified Water and Sanitary-WS-Fixtures-FinishCertifiedView ↗
01/30/2026Pass-Final PL - Up to 3 Requested FloorsPassView ↗
▾Special Inspection Requirements (DOB NOW) — 5
DateRequirementInspectorRole
12/15/2025Fire-Resistant Penetrations and JointsXIAO ZHENGspecial
12/15/2025Energy Code Compliance InspectionsXIAO ZHENGprogress
12/15/2025Fire-Resistance Rated ConstructionXIAO ZHENGprogress
12/15/2025FinalXIAO ZHENGprogress
12/15/2025Interior lighting powerXIAO ZHENGenergy_progress
▾Documents — 9 on file (BIS + DOB NOW)
▸Plans & Drawings2
▸DOB NOWPlans/Sketch2
08/18/2026Q01333984-S1Request digital key ↗
08/18/2026Q01333984-I1Request digital key ↗
▸Seals & Professional Certifications5
▸DOB NOWDPL-1: Design Professional Seal & Signature2
08/13/2026Q01333984-S1Open ↗
08/13/2026Q01333984-I1Open ↗
▸DOB NOWProgress Inspector Seal & Signature2
08/28/2026Q01333984-I1Open ↗
08/28/2026Q01333984-I1Open ↗
▸DOB NOWSpecial Inspector Seal & Signature1
08/28/2026Q01333984-I1Open ↗
▸Environmental & Asbestos2
▸DOB NOWDEP ACP-5: Asbestos Assessment Report2
08/13/2026Q01333984-S1Open ↗
08/13/2026Q01333984-I1Open ↗