← Back
Garage, residential, tax class 1
67-04 64 PLACE
QUEENS · BIN 4087954
💬 Discuss this project
1950Year Built
—Stories
G0Building Class
R5BZoning
0 sfGross Floor Area
0Units
Garage, residential, tax class 1 · Owner of record: SSTRLZ LLC · 2,500 sf lot · 0 FAR built · Flood zone X
Locations of Work
ArchitectureStructuralFire Protection
Bulkhead1p · 1 filing · 20 docs
Floor 22p · 1 filing · 20 docs
Floor 11p · 1 filing · 20 docs
1 job · most recent 07/29/2026
Air Conditioning Systems
FiledStatusContractorScopeMake / Model / Capacity
07/29/2026——Air Conditioning Systems
Cooling
Daikin Daikin 18000, 24000, 36000 BTU- R32 2,3,4 zone mini split heat pump condenser-2MXM18AVJU9, 3MXM24AVJU9, 4MSM36AVJU9 74,400 BTU · Heat Pump Outdoor ×3
1 job · most recent 07/29/2026
Storm Water/Sanitary
FiledStatusContractorScope
07/29/2026——Storm, Water/Sanitary
1 job · most recent 07/29/2026
Steel
FiledStatusContractorScope
07/29/2026——Steel
1 job · most recent 07/29/2026
Fence
FiledStatusContractorScope
07/29/2026——Fence
Building Lifecycle
All (54)Filed (6)Objection (25)Special Inspection (23)
07/29/2026
Filed — New Building
SUBSEQUENT APPLICATION FILED HEREWITH FOR PLUMBING WORK TYPE, INSTALLATION OF NEW PLUMBING FIXTURES AT BASEMENT, FIRST FLOOR AND SECOND FLOOR COLD AND HOT WATER PIPES IN CONJUNCTION TO ALT JOB Q01284610-I1.
Q01284610-P1
07/29/2026
Special inspection requirement — Fire-Resistant Penetrations and Joints
07/29/2026
Special inspection requirement — Permanent certificate
07/29/2026
Special inspection requirement — Fire-Resistance Rated Construction
07/29/2026
Special inspection requirement — Energy Code Compliance Inspections
07/29/2026
Special inspection requirement — Fenestration areas
07/29/2026
Special inspection requirement — Metering
07/29/2026
Special inspection requirement — Air barrier — testing
07/29/2026
Special inspection requirement — Insulation placement and R values
07/29/2026
Special inspection requirement — Fenestration air leakage
07/29/2026
Special inspection requirement — Air barrier - visual inspection
07/29/2026
Special inspection requirement — Fenestration and door U-factor and product ratings
06/22/2026
Objection resolved — Addressed
06/22/2026
Objection resolved — Addressed
06/11/2026
Objection raised — Admin
06/11/2026
Objection raised — Structural
06/11/2026
Objection raised — Structural
06/11/2026
Objection resolved — Addressed
06/11/2026
Objection raised — Structural
06/11/2026
Objection resolved — Addressed
05/27/2026
Filed — New Building
SUBSEQUENT APPLICATION FILED HEREWITH FOR PLUMBING WORK TYPE, INSTALLATION OF NEW PLUMBING FIXTURES AT BASEMENT, FIRST FLOOR AND SECOND FLOOR COLD AND HOT WATER PIPES IN CONJUNCTION TO ALT JOB Q01284610-I1.
Q01284610-S4
05/27/2026
Special inspection requirement — Fire-Resistant Penetrations and Joints
04/30/2026
Objection raised — Other
04/27/2026
Filed — New Building
SUBSEQUENT APPLICATION FILED HEREWITH FOR PLUMBING WORK TYPE, INSTALLATION OF NEW PLUMBING FIXTURES AT BASEMENT, FIRST FLOOR AND SECOND FLOOR COLD AND HOT WATER PIPES IN CONJUNCTION TO ALT JOB Q01284610-I1.
Q01284610-S3
04/22/2026
Filed — New Building
SUBSEQUENT APPLICATION FILED HEREWITH FOR PLUMBING WORK TYPE, INSTALLATION OF NEW PLUMBING FIXTURES AT BASEMENT, FIRST FLOOR AND SECOND FLOOR COLD AND HOT WATER PIPES IN CONJUNCTION TO ALT JOB Q01284610-I1.
Q01284610-S2
04/22/2026
Special inspection requirement — HVAC-R and service water heating system controls
04/22/2026
Special inspection requirement — HVAC-R and service water piping design and insulation
04/22/2026
Special inspection requirement — HVAC-R and service water heating equipment
04/22/2026
Special inspection requirement — Ventilation and air distribution system
04/16/2026
Special inspection requirement — Fire-Resistant Penetrations and Joints
04/16/2026
Special inspection requirement — Energy Code Compliance Inspections
04/16/2026
Special inspection requirement — Maintenance information
04/16/2026
Special inspection requirement — Permanent certificate
03/23/2026
Filed — New Building
SUBSEQUENT APPLICATION FILED HEREWITH FOR PLUMBING WORK TYPE, INSTALLATION OF NEW PLUMBING FIXTURES AT BASEMENT, FIRST FLOOR AND SECOND FLOOR COLD AND HOT WATER PIPES IN CONJUNCTION TO ALT JOB Q01284610-I1.
Q01284610-S1
02/13/2026
Objection resolved — Addressed
02/13/2026
Objection resolved — Addressed
02/13/2026
Objection resolved — Addressed
01/16/2026
Objection resolved — Addressed
01/16/2026
Objection resolved — Addressed
01/16/2026
Objection resolved — Addressed
01/16/2026
Objection resolved — Addressed
01/16/2026
Objection resolved — Addressed
12/15/2025
Special inspection requirement — Final
12/15/2025
Special inspection requirement — Mechanical Systems
12/15/2025
Special inspection requirement — Sprinkler Systems
11/24/2025
Objection raised — Structural
11/24/2025
Objection raised — Zoning
11/24/2025
Objection raised — Fire_Protection
11/24/2025
Objection raised — Plumbing
11/24/2025
Objection raised — Zoning
11/24/2025
Objection raised — Zoning
11/24/2025
Objection raised — Admin
11/24/2025
Objection raised — Plumbing
11/05/2025
Filed — New Building
SUBSEQUENT APPLICATION FILED HEREWITH FOR PLUMBING WORK TYPE, INSTALLATION OF NEW PLUMBING FIXTURES AT BASEMENT, FIRST FLOOR AND SECOND FLOOR COLD AND HOT WATER PIPES IN CONJUNCTION TO ALT JOB Q01284610-I1.
Q01284610-I1
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
SSTRLZ103/21/2026
▾Sales History (ACRIS)
DatePriceUnitSeller → Buyer$/sf
12/20/2023$450K—Private party → SSTRLZ LLC— not available
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
MSM ENGINEERING SERVICES, PLLC607/29/2026
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
MISTER EXPEDITER103/21/2026
Nothing on file for this building.
▾Special Inspection Requirements (DOB NOW) — 23
DateRequirementInspectorRole
07/29/2026Fire-Resistant Penetrations and Joints—special
07/29/2026Permanent certificate—energy_progress
07/29/2026Fire-Resistance Rated Construction—progress
07/29/2026Energy Code Compliance Inspections—progress
07/29/2026Fenestration areas—energy_progress
07/29/2026Metering—energy_progress
07/29/2026Air barrier — testing —energy_progress
07/29/2026Insulation placement and R values—energy_progress
07/29/2026Fenestration air leakage—energy_progress
07/29/2026Air barrier - visual inspection—energy_progress
07/29/2026Fenestration and door U-factor and product ratings—energy_progress
05/27/2026Fire-Resistant Penetrations and Joints—special
04/22/2026HVAC-R and service water heating system controls—energy_progress
04/22/2026HVAC-R and service water piping design and insulation—energy_progress
04/22/2026HVAC-R and service water heating equipment—energy_progress
04/22/2026Ventilation and air distribution system—energy_progress
04/16/2026Fire-Resistant Penetrations and Joints—special
04/16/2026Energy Code Compliance Inspections—progress
04/16/2026Maintenance information—energy_progress
04/16/2026Permanent certificate—energy_progress
12/15/2025Final—progress
12/15/2025Mechanical Systems—special
12/15/2025Sprinkler Systems—special
▾Documents — 31 on file (BIS + DOB NOW)
▸Plans & Drawings8
▸DOB NOWPlans/Sketch8
08/17/2026Q01284610-I1Request digital key ↗
08/17/2026Q01284610-S5Request digital key ↗
08/17/2026Q01284610-S3Request digital key ↗
Showing 3 of 8 on file for this type
▸Zoning, Tax Lot & Property Records5
▸DOB NOWZD1: DOB Zoning Diagram2
08/17/2026Q01284610-P1Open ↗
08/13/2026Q01284610-I1Open ↗
▸DOB NOWZoning Exhibit form (1-5)2
08/17/2026Q01284610-P1Open ↗
08/13/2026Q01284610-I1Open ↗
▸DOB NOWHouse Number Verification: TOPO Stamp1
08/13/2026Q01284610-I1Open ↗
▸Seals & Professional Certifications8
▸DOB NOWDPL-1: Design Professional Seal & Signature8
08/17/2026Q01284610-S4Open ↗
08/17/2026Q01284610-S3Open ↗
08/17/2026Q01284610-S2Open ↗
Showing 3 of 8 on file for this type
▸Safety & Tenant Protection2
▸DOB NOWStreet Tree Checklist2
08/17/2026Q01284610-P1Open ↗
08/13/2026Q01284610-I1Open ↗
▸Inspections & Test Reports2
▸DOB NOWSOIL REPORT1
08/17/2026Q01284610-S6Open ↗
▸DOB NOWTR4 Test Report and Plot Diagram1
08/17/2026Q01284610-S6Open ↗
▸Other Documents6
▸DOB NOWProperty Ownership Certification2
08/17/2026Q01284610-P1Open ↗
08/13/2026Q01284610-I1Open ↗
▸DOB NOWSite Survey: Initial2
08/17/2026Q01284610-P1Open ↗
08/13/2026Q01284610-I1Open ↗
▸DOB NOWLocal Law 92/94 of 2019 Sustainable Roof Zone2
08/17/2026Q01284610-P1Open ↗
08/13/2026Q01284610-I1Open ↗